Posted on Apr 26, 2009

My alpha cb24x combi boiler keeps blowing the main fuse,even when its not on,this can happen in 2mins or 2 days after i redo the fuse using 15 amp wire, why is this happening ?

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

  • Contributor 4 Answers
  • Posted on May 01, 2009
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Joined: Apr 29, 2009
Answers
4
Questions
0
Helped
1447
Points
6

A short circuit most likely on the pump or another winding, fan or gas valve. start with shutting off the power and pocketing the fuse untill ur done . dissconnect the pump supply and fit terminal blocks to make them safe. then turn the power on , but do not let the boiler run on either water or heating . let it sit for a spell and if the fuse does not blow simply replace the head of the pump, which is easier than replacing the complete pump. remember yuor not allowed to touch the gas train.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

Is AGA somehow connected to combi boiler

Some combi boilers have a 'Keep Warm' function. Check to see if your combi has this feature. This is a function where the system preheats an amount of hot water to provide instant hot water when you turn on the tap/faucet. To do this the combi will start up when it detects the stored water is below a certain temperature to reheat it ready for use. This can be turned off if you prefer not to use it.
0helpful
1answer

I've got a Alpha 240 e combi boiler..... Everything seems to be wor,kin ok but it won't start the ignition sequence .

could be air presure switch which tells pcb that fan is working and would then bring inn ignition system then main gas valve.Would suggest getting gas engineer in.pommie engineer
0helpful
1answer

I have constant 24/7 humming noise (combi boiler i think) the boiler itself is not humming but seems to be in the pipes? mainly kitchen & upstairs, there is "hot spot" for the noise as you go...

If you turn the power off and it's still there then it's not anything electrical in the flat.. it could be transferred noise from another source. I would try locating the sound by listening through a tube to locate the sound more accurately. This method of sound source location is used by old fashioned mechanics listening for engine noises and is very good at finding them..
good luck !
1helpful
1answer

I have an ideal standard he30 boiler instaled about 6 weeks ago. the boiler keeps losing presure about half a bar every 2 days if i dont top it up it will trip the fuse on the fuse board acording to the...

All the combis I've come across merely fail to fire if the pressure is not up. not only do they not fire, nothing else works including the pump and in any event the pump should not overheat just on low pressure.
water loss - try turning off the valves on the flow & return pipes [3/4 inch ones] 1 valve per pipe . This will isolate the rest of the system - rads etc Note pressure over a time period. In this mode the hot water circuit will still work but do NOT use the heating circuit
1/2 bar over 2 days is not serious but it should be found
Once you have either mended the leak in the rest of the system or found there is not one, insist on a replacement boiler
In any event having looked at the reasons given for the fuse blowing, I would definitely get a replacement.
These problems should not happen on a new boiler
I list Worcester.-Ariston-GlowWorm-Ideal- and many others who would confirm this
0helpful
1answer

My potterton boiler ignites itself after turning it on then goes out

Assuming this is a combi boiler and you mean that the main gas burner comes on then off:-
How long after - 5-20 secs check overheat thermostat Check the wires to it are firmly in place i.e. making a connection. If Ok? then you can short this out by joining the wires together - do with boiler OFF at mains electricity
Longer - say 1-2 mins check secondary heat exchanger for blockage - usually furred up inside & only solution is replacement
0helpful
1answer

I keep having to top up with water every few days, but no leaks to be found, the pressure drops down to less than one and the boiler turns off, please can you help,

what kind of heater combi? if combi you may be pressurising boiler to high ie over 1 bar boiler may be blowing off through release valve check discharge pipe
0helpful
1answer
0helpful
1answer

Vokera combi boiler

there is a zoneing valve thats suppose to be in the line to keep this from happening, might even have a check valve either way which ever one you have is bad and should be changed with a new one
0helpful
1answer

Combi Boiler pressure gauge reading 0, and radiator half on!

The first thing you need to do is to put some more water into your heating system. This is usually done by allowing water from your (pressurised) domestic cold water supply to flow into the system: On older boilers, this is done with a connection (often made with a removable hose) on the pipework just outside the boiler. Newer boilers may have a built-in connection with some sort of removable link (sometimes looks like a plastic key).

Once you've got the boiler up to working pressure (typically about 1 bar - 15 psi), you should be able to bleed your upstairs radiator properly.

This may be all it takes, though the pressure excursions you're getting when you run the hot tap suggest there may be another problem. See what happens to the pressure as the boiler heats up and cools down. There really ought to be very little pressure difference between the two conditions. If you see significant changes, this usually means that the "pressure vessel" (or in hydraulic terms, system accumulaor) has lost its air charge.

The pressure vessel is a metal container inside the boiler, usually painted in red enamel. Somewhere near the top, you will find a schrader valve (like the one on a car tyre), and you can use this along with a tyre pump to replenish the air in the top of the vessel. This will reduce your pressure transients for a while, but you need to keep an eye on it. If the problem returns, you probably need to replace the pressure vessel (or clag another one into the plumbing alongside the boiler).

A.
Not finding what you are looking for?

947 views

Ask a Question

Usually answered in minutes!

Top Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Paul Carew

Level 3 Expert

3808 Answers

David Spradling
David Spradling

Level 3 Expert

13520 Answers

Are you a Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...