What is a U80 meat probe error and how do I fix it?
Error U80: Shorted meat probe
1) Food, moisture, or other substance is in the socket or on the oven connection end of the meat probe. Check: Verify proper operation with new probe (replace probe). If still fails with new probe check wiring of housing to eliminate shorting to sheet metal. Solution: Clean socket and meat probe.
2) Bad meat probe (shorted). Check:Use new meat probe to test for correct values in the service screens. Solution: Replace meat probe.
3) Shorted socket or wiring. Check: Test socket at connector J20 on relay board. Solution: Replace meat probe socket.
Functionality when error U80 reported: Cooking and cleaning are available but meat probe options will not be available.
User action/solution:
1) Verify oven connection end of meat probe is clean and no food, moisture or other substance in is the meat probe socket.
2) Call for service.
×