Stopwatch second hand not reseting to zero ar 0532

2 Answers

Les Dickinson

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Giorgio Armani Master 18,429 Answers
  • Posted on Sep 13, 2013
Les Dickinson
Giorgio Armani Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Nov 01, 2009
Answers
18429
Questions
2
Helped
1405253
Points
62248

PULL THE CROWN OUT TO SECOND POSITION THEN PRESS THE START BUTTON TILL IT GETS TO ZERO THEN PUSH CROWN BACK IN

Testimonial: "When the crown is fully out the start button doesn't work"

  • Richard Kelso Sep 13, 2013

    When I press the reset button it resets to 27 instead of 0

  • Darryl Chambers
    Darryl Chambers Sep 25, 2014

    Excellent help, just to clarify for others you need to press the start button repeatedly one push for every second to get to the top before pushing the crown back in

×

Thiago Simoes

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

  • Contributor 2 Answers
  • Posted on Jul 23, 2015
Thiago Simoes
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Joined: Jul 23, 2015
Answers
2
Questions
0
Helped
647
Points
10

Pull out crown to 2nd position and press "Start" and "Reset" buttons at the same time for over 2 seconds. When the buttons are released the internal circuit has been reset. Now press "Start" button till it gets to zero position then push crown back in.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

What are the three little faces for? do not have instructions

Your watch is a chronograph or a watch that includes a stopwatch. Two of the three dials are for recording minutes and hours with the large sweep second hand recording seconds. Pushing the upper button starts and stops the stopwatch function. Pressing the lower resets everything to zero. The small bottome dial is the seconds hand for the watch, it always is moving.
0helpful
2answers

Pulsar chrono hand alignment

mcdedevito75 here, Return to the watch rep[air that installed the battery for adjustmaet.
4helpful
2answers

Stop watch will not reset to zero

pull the crown full out reset all hands set time set alarm or second time if you wish and press the crown back.
3helpful
3answers

I have a seiko chronograph sports 150 watch; had the battery changed a few day ago and just noticed that the second hand & stopwatch hands are not 'centered'. is ther a way to reset this ? cheers

As jimmyguru said.
1. Pull the crown to the second position (all the way out)
2. Push and hold the reset button and allow the chronograph hand to rotate near the 12 o'clock position.
3. Release the reset button.
4. Repeatedly push and release the reset button to find tune the hand position until it is right at 12 o'clock.
5. Push the crown back in.
8helpful
1answer

Resetting stopwatch dials - Armani AR5331

When you reset the big seconds hand to zero, the hour and the minute hand are not engaged in this function, so, there is no fault with the watch movement.
Do as follows:
1) pull out crown and set the hour and minute hands at 6 o'clock (they must be lined perfectly in opposite directions)
2) push the crown in half way back (not completely)
3) push and hold the button at 2 o'clock (set the big seconds hand to zero) and release it when done
4) when big seconds hand is zeroed push the crown back in
5) pull the crown out again and set desired time
6) push the crown back in.
If all actions described do not work, you will have to visit your nearest watch repair shop and ask to refit chronograph hand as in this case it is out of balance (not pointed at exact mark).

Rate me, please.
Apr 03, 2009 • Watches
3helpful
2answers

Festina Dashboard watch - Adjusting the hand of the stopwatch

Your watch has quartz movement and stopwatch adjustment by one step (one full second) only. That means you will not be able to adjust stopwatch hand by using pushers on your watch as each push of the pusher will advance stopwatch hand for the full second, not the fifth or the tenth of the second, and the hand will stay slightly off anyway.
This happenened because the IC (integrated circuit) in your watch miscalculated the teeth count on chronograph wheel and stopped one or two teeth past or under the zero point. It doesn't happen very often, but in your case it did and the only solution is to find your nearest watch repair shop and ask for resetting stopwatch hand to zero.
This procedure needs partial disassembling of the watch and quite a great skill as the stopwatch hand must be removed and then refitted with great accuracy. All this needs to be done by very specialized tools as well.
I think this is the only solution of your problem unless you can live with that and just leave it as it is.
Do not forget to rate, please.
38helpful
2answers

Tag Heuer Link, stopwatch seconds hand stops 2 seconds before 12

Pull crown out to position 2 [in between unscrewed (1) and pulled all the way out (3)].  Tap Button B (bottom) to reset by step back to zero.
Incidentally, Button A works Hours register in same manner for position 2.  You can similarly reset second and 1/10th with Buttons A and B, respectively, while in position 3.  Cheers! 
18helpful
1answer

Re-set quartz chronograph sweeping second hand

Easy Soultion worked for me. Believe Me I was worried only had the Seiko Sportura for a week now. My second dial for the stopwatch was re-setting to 5 seconds instead of zero. The Solution is
1. pull the Crown all the way out ( In the position you take the crown to set the time , second click ).
2. To set the minute face of stop watch , keep pressing the top button untill it is zero. To set the second needle to zero keep pressing the bottom button untill it reaches zero or where you like it to re-set each time. Depend on you.
3. Once all neddles of stopwatch are at resting postions ( usually zero) secure the crown back to its normal postion. Test your stop watch , hopefully it will go back to zero when you press the reset button. C

Glad to help. [email protected]
3helpful
2answers

Resetting stopwatch dials - Armani AR5331

Pull the crown to first position (where you set the date) then adjust the dials with buttons.

uhrmacher
39helpful
3answers

Reset Stopwatch Hands on CL1111 ?

Try setting the crown to position 2 - i.e. the position normally used to adjust the date.  Then use the top and bottom stopwatch buttons to adjust the minute hand and 1/10th hand respectively.
Not finding what you are looking for?

399 views

Ask a Question

Usually answered in minutes!

Top Giorgio Armani Watches Experts

Kolbrun...

Level 3 Expert

1228 Answers

ADMIN Eric
ADMIN Eric

Level 3 Expert

39391 Answers

Are you a Giorgio Armani Watch Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...