Change the thermocouple.
http://home.howstuffworks.com/pilot-light.htm
SOURCE: garland deep fryer
Pilot lite working. When temp switch turn up to 365 you can here a click but gas burners do not light. Sometimes when you turn the switch back and forth the burners will light and bring oil to temp. and shut off but as oil cools burners do not come back on.
Dan
SOURCE: high limit kicks out fryer and pilot light can
Since you've mention the pilot light goes out at 400 degree F, then we are talking a gas Deep Fryer. The deepfryer usually use at 350 degree F for chips or else. Because the oil will start breaking down its quantity of frying very quickly over that temperature. Most people set at 350 degree F. Now we comes back to your problem, First you should have a deep fryer thermometer they espcially made for deep fryer, (You only mention 400 or better ) that make me think you're only guessing. Knowing the temperature is very important, most Hi limit is set at 420 degree F.
To me it seen the Hi Ltd control is working and that is why it cutting out the pilot when it reach its limit but we don't know what temperature that when the hi limit cutting out at.
When you have a thermometer, put it in the cold oil and turn the temperature to 100 degree F to see what the temperature control cutting out at. slowly increase your setting until it cutting out at 350 degree F . If you set at 250 degree F and the thermometer already reaching 350 degreen F then don't go any further , your temperature control is defective and need to be change a new one.
This is only the first step, you still have to check out the Hi ltd control to see how good its condition is,so far your information say it cutting out at 400 or better. But you've to be sure, because it is a safety control. Hope that will help you , God Bless.