The green light comes on and you can hear a click when you press the power button but I don't get a picture or any sound. What is the problem?
This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems, to activate this turn the unit on let it shutdown then press the input and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source)
Posted on Sep 20, 2007