Question about Whirlpool ED2FHEXN Side by Side Refrigerator
System was working fine. Refrigerator was moved slightly to get behind it. The icemaker has not worked since. I followed the justintimer/catriver posts to get started on troubleshooting. The water line is not frozen, but no water is provided. I measured the voltage at the valve, and when I jumper L & V no voltage is provided to the valve. Likewise, jumpering T&H had no effect. In all cases, I had the infrared detector turned on and I manually moved the door and bucket so that the light went from blinking to full on. The whole system is acting like it is turned off or not getting power, but I don't know how to troubleshoot any further. Any help is much appreciated.
It sounds like you have done all you can before calling the repairman. When you moved it you may have pinched the line or restricted the water input somehow. Check this first.
Posted on Dec 26, 2007
SOURCE: Icemaker not working
The power to valve is not constant, it is only applied for an extremely short period, fault is either the infrared reciever or the main PCB, this is located in the back on the right in a black bpox , as veiwed from the back. Regards Advisor
Posted on Aug 30, 2007
775 views
Usually answered in minutes!
replace main module assembly on ice maker, replaced emitter and transmitter. Show to be working properly. Jumped T to H but the motor will not run. No power is getting to the ice maker
The ice dispenser froze up so no ice and no water comes out. I've thawed and cleaned the dispenser, but still no water. I'm thinking the water line is also frozen somewhere.
×