How to adjust a GG40T6A water heater - Water Heaters

1 Answer

Gene Haynes

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Water Heaters Master 5,391 Answers
  • Posted on Mar 19, 2013
Gene Haynes
Water Heaters Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 07, 2012
Answers
5391
Questions
0
Helped
2604445
Points
14124

Adjust temperature?
http://waterheatertimer.org/How-to-adjust-temperature-on-water-heater.html

Troubleshoot by type of gas control?
http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intellivent

Maintain water heater:
http://waterheatertimer.org/How-to-maintain-water-heater.html

Add a comment with more information as needed

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

1 Related Answer

Anonymous

  • 395 Answers
  • Posted on Oct 08, 2010

SOURCE: I have a GE smart

The pilot light jet may have got a little bit of dirt or grit in it which is preventing it from keeping alight. Try probing the jet with a fine piece of wire to see it the blockage can be dislodged. You may have to unscrew the jet to clear it by blowing air through it. Make sure gas is turned off first before removing any parts.

The pilot light also has a thermocouple that allows gas to the pilot light while the flame is burning. If flame goes out it shuts gas off to the pilot jet. The thermocouple is bypassed by a switch during the initial ignition and once the thermocouple warms up after a minute or two of holding in the bypass switch, it should maintain the pilot. If, after cleaning, the pilot light keeps going out, it would seem that your thermocouple is faulty and needs to be replaced

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How do I drain a GE GG40T6A gas hot water tank?

http://waterheatertimer.org/Water-heater-will-not-drain.html
http://waterheatertimer.org/How-to-install-gas-water-heater.html

Turn power off, turn water off, open tub spout, Connect hose and open drain valve?
Gene

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

What do I have to do to drain and disconnect GG40T6A model

1) Copy following link for installing new gas water heater, and use steps to move water heater, and then re-install.
http://waterheatertimer.org/How-to-install-gas-water-heater.html#install
http://waterheatertimer.org/Water-heater-will-not-drain.html

2) Don't forget to tape plastic bag over disconnected gas connections to keep from getting dirty.
Dirt in the gas line, or on the threads can cause gas control valve to malfunction.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Have a GE GG40T6A gas hot water tank. Leaking really bad out of the pressure relief valve. It is a rental property, gas was off to the house (tenants moved out in the night). When the gas company turned...

12 year old water heater is getting near the end.
Some tanks last 20 years, but that's the exception.
To find exact age of your brand water heater:
http://waterheatertimer.org/pdf/WaterHeaterSerialNumberDecoder.pdf

Leaking TP valve:
1) Lift TP lever and gently lower back into position to see if that stops leak.
Occasionally something gets stuck in the valve.
2) Sometimes water heater temperature gets turned up because heater is not producing as much hot water as before, and higher temps cause TP to release pressure because of overheating.
Dial temperature down to 120 degrees.
http://waterheatertimer.org/How-to-adjust-water-heater-temperature.html

3) If steps above don't fix problem, replace TP valve >> TP valves have 125 or 150 degrees rating >>> older tank shouldn't be running above 125 because higher temps cause more pressure on tank, so thermostat should be lower than 125 degrees TP rating.
Buy replacement TP at any hardware store + a roll of teflon tape to seal pipe threads.
Turn gas control to pilot ... this will keep pilot lit but burner will not fire.
Let water cool, and then drain some water out of tank.
If TP valve is on side of tank, then open drain on side of tank and drain water until it is lower than valve level. Open bathtub spigot to let air into line.
http://waterheatertimer.org/Water-heater-will-not-drain.html
Be careful around water that is higher than 120 degrees F >> you can get burned quickly >> apply cold water to any burn.
Use pipe wrench and unscrew TP valve counterclock-wise.
Install new TP and put teflon tape on threads.
Re-fill tank completely and open tub valve on hot side until water is running >> then turn gas control back to original position.
Do not fire up any water heater before tank is completely full of water or this could damage tank.

To read more preventative information about water heater leaks and age problems:
http://waterheatertimer.org/Water-at-bottom-of-water-heater.html
3helpful
1answer

I need to adjust water temperature, and dont have a manual. i have a 81v40d C model , 40 gal electric.

Hi,

Here is a tip that I wrote to help people understand how to adjust the temperature on their electric hot water heater.

Electric Hot Water Heater Temperature Adjustment
heatman101
4helpful
1answer

I have a GE smart water heater model GG40T6A. the pilot light will not stay lit. what can i do?

The pilot light jet may have got a little bit of dirt or grit in it which is preventing it from keeping alight. Try probing the jet with a fine piece of wire to see it the blockage can be dislodged. You may have to unscrew the jet to clear it by blowing air through it. Make sure gas is turned off first before removing any parts.

The pilot light also has a thermocouple that allows gas to the pilot light while the flame is burning. If flame goes out it shuts gas off to the pilot jet. The thermocouple is bypassed by a switch during the initial ignition and once the thermocouple warms up after a minute or two of holding in the bypass switch, it should maintain the pilot. If, after cleaning, the pilot light keeps going out, it would seem that your thermocouple is faulty and needs to be replaced

0helpful
1answer

How do i adjust the water tempature from the hot taps ?

you don't adjust hot water temp from the taps...

you can only adjust from the water heater.

what water heater do you have?
2helpful
1answer

Gg40t6a polit light will only light when polit button is held down.i have cleaned the thermo coupler and orfice at no avail.

Does the gas flame fully heat up the coupler
if not then clean out the gas jet nozzle
if yes then replace the thermo couple

3helpful
1answer

GE Smartwater Heater model# GG40T6A won't stay lit

Look and see if your pilots flame is touching the themocoupling ,if it isnt then cleane your pilot orfice.If that dosnt work replace thethermocoupler.I would also check the draw. Hold alit match or a cigerett up to the draft diverter (the air space between your heater and the vent. If it dosent draw the smoke up the vent it meanes your vent is stoped up or you need to raise it.
1helpful
1answer

Pilot Light will not remain lit

Try this, turn the black gas ****, on top of the control box, to the Pilot position. Set the temp. control on the front of the box to the desired temp. Then, hold a match or whatever else you use to light it, next to the end of the pilot, then, while holding the match to the pilot, press the reset button on top. When the pilot lights, continue to hold the reset button down for about 1 minute. Then, after a minute, turn the gas **** to the ON position, then it should remain on.
Not finding what you are looking for?

109 views

Ask a Question

Usually answered in minutes!

Top Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Paul Carew

Level 3 Expert

3808 Answers

David Spradling
David Spradling

Level 3 Expert

13520 Answers

Are you a Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...