  • 918 Answers

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action

  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Posted on Jul 28, 2014

Ad

1 Related Answer

Anonymous

  • 1 Answer

SOURCE: looking for repair manuals and error codes for

Could you please advice about ERROR 29 fo C956i/C966i treadmill.

Posted on Mar 04, 2010

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Can I adjust the stride length?


Precor EFX 546 Version 1 Elliptical Trainer (Refurbished)

www.amazon.com > ... > Elliptical Trainers

Amazon.com, Inc.
Rating: 4.3 - ‎9 reviews
Working out on an elliptical can burn as many calories as working out on a treadmill. ...allowing you to go forward and backward, as well as adjust stride length to target ...The Precor EFX 546 allows you to stride smoothly while holding the ...

EFX® 546i Elliptical Fitness Crosstrainer™ ' Precor

www.precor.com/en-us/.../efx-546i-elliptical-fitness-crosstrainer-33
With the unique Precor CrossRamp® technology, users can alter the path of the EFX®546i between 13 and 40 degrees in both forward and reverse stride motions, cross ...Excellent stability and freedom of movement for users of all sizes.

FAQ - Precor


Dec 28, 2015 | Precor 546 Elliptical

1 Answer

My precor efx 546 makes noise like a squeaking in left pedal it seems I tried to tighten pedal but I the whole bolt and screw turn together and the other pedal makes no noise


This squeak is normally caused by a bad bearing in the wheel. In order to provide you with the correct wheel, I will need your serial number. The following link will take you to our Precor EFX 546 page.

Repair Parts for Precor EFX 546 Ellipticals SPORTSMITH net

May 29, 2014 | Exercise & Fitness

1 Answer

Precor efx 546 wobbles when raising incline


It may be either the front shroud is installed incorrectly or broken, or the corkscrew for the incline motor is bent. If it is bent, it would need to be replaced.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

Feb 10, 2014 | Precor Efx 546 Version 1 Lower Body...

1 Answer

How to repair a 546 efx precor


Assuming the buttons are working, the numbers change on the display, and the incline works, it may be the lower circuit board or the generator. If it is a very old unit, it may be the electromagnet or the data cable that connects the two circuit boards.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

May 08, 2013 | Precor Efx 546 Elliptical Version 2...

1 Answer

Precore efx 546 error 30


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Jan 31, 2013 | Precor EFX 546i Elliptical Version 4

1 Answer

Error 44 precor eliptical 546


Precor Error 44, Un-commanded Lift Motion Probable Cause 1. Intermittent or bad connection in the lift position sensor(potentiometer).
2. Lift position sensor (potentiometer) is bad.
3. Lower PCA is bad.
Corrective Action
  1. Bad or intermittent connection of the lift position sensor (potentiometer) is the most common cause of the error 44. Inspect all wiring and connections related to the lift position sensor (potentiometer). Repair or replace wiring connections as necessary.
  2. Monitor the lift position number displayed while operating the lift in diagnostics mode. If the reading makes large changes or is erratic, the lift position sensor (potentiometer) is likely bad. Replace the lift position sensor (potentiometer) or lift motor if the lift position sensor (potentiometer) is internal to the lift motor.
  3. If the lift moves without any command entered either manually or through a program, replace the lower PCA.
Precor Error Code 44

Nov 22, 2012 | Precor EFX 546i Elliptical Version 4

1 Answer

What is error 45 on the EFX 546??


Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.


Precor Error Code 45

Nov 11, 2012 | Precor EFX 546i Elliptical Version 4

1 Answer

Error 45 on Precor EFX 546 Elliptical


Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.

Precor Error Code 45

Jul 19, 2009 | Precor EFX 546i Elliptical Version 4

Not finding what you are looking for?
Precor EFX 546i Elliptical Version 4 Logo

Related Topics:

206 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

NOEL
NOEL

Level 3 Expert

8546 Answers

daf62757

Level 1 Expert

31 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

34001 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...