P-21: Color regist test pattern failure
1 Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty.
2 Change the image transfer belt unit if the transfer belt is damaged.
3 Change the PH unit.
4 Change PRCB.
run halftone prints from service mode to isolate which color is having an issue.
check all image units
SOURCE: The printer has stopped functioning all together.
C3851: Abnormal Low Temp. (Heater)
1. Turn OFF the Main Power Switch.
2. Turn Main Power Switch ON while pressing the Utility/Counter key.
3. Touch [Trouble Reset].
4. Check to make sure that [OK] is displayed and the it has been reset.
5. After turning off the Main Power Switch, turn it on again more than 10 seconds after and check if the machine starts correctly.
Reset your Toners and Imaging units for Minolta Bizhub and CF series.
http://www.chipreset.eu
Testimonial: "This is exactly what I needed to do to fix this error. I got it fixed a long time ago but this is the correct answer!!!"
SOURCE: konica minolta bizhub c250- error code c-0212
Something is going wrong with your LCT!
I am looking into it...
SOURCE: how do you reset the life of the transfer unit on the Bizhub C250
Yes,
Remove Trasfert belt unit.
On the left handled remove one screw ( spring fixer) and remove right srew (over the belt / bar whit finger fixee).
Remove, on the left spring stoppage and metal handled.
Remove black little srew and take to hand fuse contact.
Change fuse (behind) with new identical fuse and reassembly.
It may be reset trasfert belt counter.
Sorry for my not good english.
Bye.
SOURCE: Error code c0202. What is
Most likely there is paper stuck in the very back behind one of the trays. Take both trays out and see if there is any paper jammed (could be a small piece). Put trays back in but leave them open, turn off the printer, unplug it, wait 5 minutes, plug it back in, turn it back on and push in the trays.