E3-10 is usually charge or transfer corona leakage. my guess would be charge corona end blocks need changing or replace the whole unit. also b4 replacing the charge corona unit check that the scorotron grid is clean and has no lint on it and that the corona wire is not slack.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
on the 8020 it depends on what the code is. there is usualy a good reason why it is giving an error code. some codes can be reset ei fuser codes (E 04_xx) If you could please supply me with the correct code then i might be able to help you.
What are you tring or want to reset? Try the rest botton on the control pannel. Or give some more info. like the error code being displayed, then I may be able to help.
That could be a few things. Your corona wires might need replacing. Something with the middle transport section, where one of the corona assemblies is at, is not making contact properly. Or it could be the high voltage power supply.
press and hold paper tray,zoom down,1 simultaniously you will enter in programe.F will come on display press 6 it will appear F6 press stark key change the value and then start key to exit the program press and hold these keys paper tray,zoom down stop key
We have done all the necessary maintenance, while trying to operate,
error e 310 come on.
Please help to do the needful
×