Code ee 5 on sharp microwave model rcd 2200m

Unit shows a code EE5 ... Model Sharp Commercial Microwave Model RCD 2200 M...

1 Answer

William Miller

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Sharp Master 9,179 Answers
  • Posted on Jan 17, 2013
William Miller
Sharp Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Sep 15, 2006
Answers
9179
Questions
3
Helped
4479400
Points
21747

It may be that the voltage selector on the back of the oven is not set to the proper level of your AC supply.

It will probably have settings for 208VAC or 230VAC.

Chances are your oven is set to 208VAC but it is on a 230VAC line.

Refer to your owner's manual for specific details.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

5 Related Answers

MicrowaveSvc

William Miller

  • 9179 Answers
  • Posted on Aug 09, 2008

SOURCE: Sharp Carousel Microwave R-320FQ Serial # 26805 Mfg. Dec. 2002

The first thing I would suggest is a hard reset. Unplug the unit for a minute or so. Then plug it back in, set the clock and try again.

Let us know if the hard reset does not fix it.

It may have an intermittently shorting keypad or another problem on the control panel, which we repair for customers nationwide with our guaranteed $39.95 service.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Ad

Anonymous

  • 6784 Answers
  • Posted on Jun 03, 2009

SOURCE: Sharp R1514 - handle is stuck "in"

The mechanism has failed. simply replacing this handle(push) mech will fix this issue.

MicrowaveSvc

William Miller

  • 9179 Answers
  • Posted on Aug 30, 2009

SOURCE: Sharp model R-1871 shuts off every 59 seconds

This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
[email protected]
http://www.microwavedisplay.com

b27054b.jpg

Testimonial: "traced to motor for damper. Would not have had a clue without this information provided by fixya"

MicrowaveSvc

William Miller

  • 9179 Answers
  • Posted on Aug 30, 2009

SOURCE: I need a manual for Sharp Microwave/ Convection R7A85

You can download that here free.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Anonymous

  • 2 Answers
  • Posted on Mar 27, 2010

SOURCE: how do i remove sharp microwave from wall model

The only problem that ricksterboy doesn't list, is there are also two screws located underneath as well. You have to take off the filter screens to find them. They secure into steel supports inside the microwave.
No getting the micro off the wall w/o removing them, or using a sledge hammer...which after all the time we used trying to get the thing off the wall, seemed like a good theraputic option.
Lucky we took off the vent cover and discovered the additional anchors.

Good luck!

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer
0helpful
1answer

Sharp R-CD2200M Microwave Maintenance Mode CC1,2,&3 magnetron hours exceeded.

If it shuts down it is faulty.

Take it in for professional repair. They are too dangerous to work on. There is 125,000 volts in the capacitor just waiting for you to get near it. The magnetron will make you blind in about 15 seconds and the core is a poisonous heavy metal. It is a $2,190.00 commercial microwave so worth getting repaired professionally. It must have earned its money.

Service Manual, and note:

WARNING TO SERVICE PERSONNEL: Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc..)

Sharp CD2200M Service manual ' Manualzz

https://manualzz.com > Sharp > microwaves > CD2200M
TopPage RCD2200M SERVICE MANUAL S2801RCD22MP COMMERCIAL MICROWAVE OVEN MODELS R-CD1800M R-CD2200M In the interest of user-safety the oven should be


0helpful
2answers

User manual for a model R-209 AK counter top carousel microwave

Free Sharp Microwave Oven User Manuals ' ManualsOnline ...

kitchen.manualsonline.com > ... > Sharp > Kitchen Appliance Sharp
Products 1 - 50 of 359 - Top Automotive Device Types ..... Sharp M I C R O WAV E O V E N OPERATION MANUAL. Pages: 0 ... Sharp Microwave Oven 209H ... SharpOperation Manual Microwave Oven R-308H, R-305H .... Sharp Microwave OvenMODEL R-2197 ... Sharp over the counter microwave oven operation manual ...

SHARP MICROWAVE OVEN Parts ' Model r209ak ' Sears ...

www.searspartsdirect.com/model-number/r209ak/0958/0123245.html
Shop for SHARP MICROWAVE OVEN repair parts for model r209ak at Sears ... Find part in diagram SHARP Countertop Microwave Model # R-209AK.
0helpful
1answer

I need instructions on how to use Sharp Convection microwave Grill 2?

Best way short of Sharp is Google the model number of the unit with "manual" to try to locate free one online.
0helpful
1answer

Sharp microwave model R-1406 control panel has no light. unit works but you can't tell anything as the led is blank.

We regularly repair such control units for customers nationwide by mail for $39.95 postpaid with a one-year guarantee.

Details of our service are at our Web site, along with a video showing how to remove a typical over the range control panel assembly in under 5 minutes.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
0helpful
1answer

Getting an "EE" and it

Check this against your code, but iff EE is flashing you may have an internal electrical fault that needs to be checked out by a repair person.

  1. Frigidaire

  2. GE

  3. Panasonic

  4. Sharp

  5. Whirlpool

Sharp commercial grade microwave codes....
EE Mode Reason Action Required EE 1, EE 2 Magnetron failure

Call for service*
EE 3 Both magnetrons failed Call for service. EE 4 R-23GT, R-24GT and R-25JT only
Voltage too high Follow instructions on page 5 of Operation Manual under VOLTAGE SELECT to change from 208V to 230V. If problem is not corrected, call an electrician. EE 5 R-23GT, R-24GT and R-25JT only
Voltage too low Follow instructions on page 5 of Operation Manual under VOLTAGE SELECT to change from 230V to 208V. If problem is not corrected, call an electrician. EE 6, EE10, EE16 Thermistors failure Call for service. EE 7 Exhaust air temperature too high

Check that nothing is blocking air intake openings on oven back or that oven exterior is very hot. Correct. Wait a few minutes and try again. If problem persists, call for service.
EE 8 Circuit failure Call for service. EE 9 Maximum time is exceeded

Check page 11 in the Operation Manual. Touch STOP/CLEAR pad, and reprogram correctly.
EE 0 Fan lock error Call for service. EE17 Magnetron temperature too high

Touch STOP/CLEAR pad. Wait a few minutes and try again. If problem persists, call for service.

* EE 1 and EE 2: Can continue to use oven before service; however, check food carefully as additional cooking time will be needed.

Any time the EE is flashing, the servicer should be called. When EE is not flashing, check the reason and correct. Service is not necessary.

5helpful
1answer

The microwave screen says EE2

The fault code "EE2" on a Sharp commercial microwave oven means that the magnetron 2 circuit has a problem and is pulling too little or too much current.

It may be the magnetron, high voltage transformer, high voltage diode, wiring, etc.

Since you didn't mention your model number I can't say for sure, but magnetron 2 is usually the lower magnetron in a Sharp.

You can order Sharp commercial microwave parts here.

If you need more help, we may have the service manual for you to download free.

But we would need the model number.

Please note that FixYa is not currently notifying us Experts when Clarification Requests are answered.

So to allow us to help you effectively (at no charge), please post a
NEW problem to FixYa, and please include your brand name and the full model number from the tag in or on the unit and your symptom, "EE2" code.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
1helpful
1answer

Ee5 ERROR CODE on r-22gtf

Your voltage selector is not set properly.

The R-23GT and the R-24GT have been preset for 230V operation.

If you need to change this oven for 208V operation, follow instructions below.

1. Unplug oven.
2. Remove one screw(A) from the Voltage Select Cover located on back of the oven near the bottom.
3. Remove the Voltage Select Cover and rotate 180 degrees.
4. Reinstall the Voltage Select Cover using one screw(A) removed in Step 2.
5. Plug power cord into wall outlet.

Your oven is now ready for 208V, 60Hz operation.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
0helpful
1answer

3 year old unit, oven works, microwave does not

hi,

You may need a new magnetron, contact sharp or the store you got it from; most microwaves have a 3-5 year warranty on the magnetron. If it's not in warranty, find a good appliance repairman, this is a difficult and dangerous repair job.
0helpful
1answer

Ee 5 code on 24GT...

Take a look at this website, its says your voltage is too low..... http://www.applianceaid.com/micro_faultcodes.html#Sharp
Not finding what you are looking for?

3,005 views

Ask a Question

Usually answered in minutes!

Top Sharp Microwave Ovens Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Sharp Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...