I have a Kohler Confidant 5, model 5ckm21 generator in my RV, serial # 326827, spec# 101228. It worked fine one evening and the next day it wouldnt stay started unless the start button stays depresse

Confidant 5 Model 5CKM21 Serial 326827 Spec 101228

1 Answer

musicman66

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 2 Answers
  • Posted on Oct 17, 2013
musicman66
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Oct 17, 2013
Answers
2
Questions
0
Helped
2130
Points
1

No 14vac coming from generator to control board.--cause can be regulator board on end of generator---dirty brushes or worn out brushes==b1 and b2 winding open that outputs the 14vac--my problem was blown regulator board

1 Related Answer

Fred Yearian

  • 5603 Answers
  • Posted on Aug 11, 2009

SOURCE: kohler confidant 4 generator service manual and wiring diagram

First thing is to check oil level as low oil pressure will shut it down.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

Kohler Confidant 5 Generator. I put in new spark plugs and gas line. It runs but will not put power in motor home. How to change or check brushes?

Question edited for clarity.
Two duplicate Questions deleted and amalgamated into one question. Refresh the page to see your question published.

Help in the link, it is common.

https://www.google.com/search?q=Kohler+Confidant+5+Generator%2C+no+power+output

..
1helpful
1answer

HOW DO YOU REMOVE FULE FLOT BOWL KOHLER CONFIDANT 5 5CKM21

It is not a float issue because the motor cannot consume the entire contents of the gas chamber in one instance of a surge. This is a throttle issue.
0helpful
1answer

I have a Kohler Confidant 5, model 5ckm61 generator in my RV, serial # 338225, spec# 101218. It worked fine one evening and the next day it wouldnt stay started unless the start button stays depressed ....

The control board needs to sense a voltage coming of stator windings to complete the run circuit or else it will shut down. Check the stator and rotor windings for resistance and shorts
0helpful
1answer

I have a Kohler 12.5 KW marine generator on my houseboat that has a problem I was hoping you could help me with. Specs: Kohler 12.5 KW 79 CID 23HP Mfg date 9-10-96 Gen Engine Serial # 06919 L-29-R

there are some magnets behind the flywheel to cause the battery charging system to recharge the batt. sometimes they come unbonded/loose from the flywheel and cause the engine to become hard to turn. I would start there first.
0helpful
1answer

Kohler Confidant 4 puts out to much voltage

Are you running the gen and plugging in the RV at the same time? I assume it is wired right and you have a transfer switch? Are you saying the voltage is fine when the RV isn't plugged in?
1helpful
2answers

Kohler confidant 4 generator service manual and wiring diagram

First thing is to check oil level as low oil pressure will shut it down.
0helpful
2answers

Generator quit working

i used to work at a repair shop for kohler 98 bucks an hour to check it out. and for them to repair who knows?. i would do my best if not in a hurry to figure it out on my own. you can purchsae a service manual and stick with your basics; spark gas, and from there go deeper.
Not finding what you are looking for?

1,996 views

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66955 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...