It would start up for some seconds then suddenly goes to standby.
SOURCE: returns to standby
Green flashing 3 times = digital DC - DC converter fault
Red flashing 3 times = scan circuit fault
SOURCE: plasma wnt stay on
I have had this problem in some models of plasma sets before. In most cases the power supply and main drive boards had to be replaced. In a small number of cases the failure was the screen itself.
In all cases, the cost of the repair was expensive. For the screen failure, the set was scrapped.
Jerry G.
SOURCE: Problem starting a plasma
When it looks like its going to start up and it dosent then its an indication that one of the sweeps didnt start up. When you hit the power switch, the power supply sends an ok signal to start up the horizontal and vertical oscillators. When these start up they go to there respective drive circuits and then the vertical will send a signal to the power supply to keep on going so then the horizontal circuit starts up and sends an ok signal to keep going so then the set comes ob,\. If one of the two doesent start up and stay running then the power supply shuts down. To troublwe shoot these sets you need a service manualo and a good multmeter and a scope wouldnt hurt slso. This set has no user servicable parts inside of her so you need to take the set to a pro to assist you in the repair. Good Luck
SOURCE: Philips 42 in. Plasma shut down
Thank god we purchases the ADVANCED extended warrenty. This tv has been nothing but problems.
Fuzzy picture, picture shutting off after 20 sec coming back on and now blog of colors shut off never to come on again. 7 blinking red lights on the front. Waiting for the repair man again.......
SOURCE: idlcd32tv27hd comes on for 1 second then goes to standby
REPLACE 2-4 BULGING CAPACITORS IN THE POWER SUPPLY BOARD, PLEASE LET ME KNOW IF FIXED. THANKS
114 views