Minolta QMS 2200DL
I swaped out a transfer belt that was working in a different unit and I still get the same message . I cleaned all the contacts that I could find and still the same message . I don't know what else to do . Can you help ?
The error message under that title is "Have the image transfer belt replaced soon." It's a new unit, but resists doing the Gradation Adjust. Tried returning the old belt (which was working before the replacement) and error message remains, so apparently the problem is not with the new belt.
System Error Clear (System 1 -> Initialization) gives "Result: OK" but has no effect; the problem remains after machine restart. However, it does NOT at any time give L-5 error (Transfer belt unit accumulated rotation time excess warning), just continues to say "replace image transfer belt unit", and will not allow anything else to proceed. What am I missing? (Transfer belt clutch malfunction?
CAUSE: Failed 1st Image Transfer Pressure/Retraction
Motor (M11) and/or Transfer Belt/Cleaning Unit.
SOLUTION: Perform an I/O check on M11 then verify that
the motor and Transfer Belt/Cleaning Unit drive components are not bound up.
Replace M11 (p/n 9314 1100 72) and/or the Transfer Belt/Cleaning Unit (p/n 4049
212) as needed.
IMPORTANT: If
the error reoccurs, there is probably an open ICP on PWB-MC (due to a current
overload caused by M11 or a bound Transfer Belt/Cleaning Unit). Replace PWB-MC
(p/n 4036 7811 07).