I have a kerosine type reddy heater 55,000 btu. i plug it in and it starts and has heat but only runs for about fifteen seconds. it will keep repeating this as many times as I plug it in. i had real old kerosine in it the first couple of times i started it i'v emptied it and put fresh kerosine in it. i'v tried starting it about a undred times and it just never stays on.
Did you check the plug. If it is fowled or the plug is not gapped properly it will not fire or run efficently and will shut off.
What is the model number? Could be a number of things, depending on which technology is used on your particular 55,000 btu heater.
Hi,
Here are a couple of tips that I wrote that tell you how to troubleshoot a Torpedo or Reddy heater...
Reddy Heater - Troubleshooting Torpedo Heaters
Torpedo Heater Pump Pressure Adjustment
heatman101
Hi,
Here are a couple of tips that I
wrote that tell you how to troubleshoot a Torpedo or Reddy
heater...
Reddy
Heater - Troubleshooting Torpedo Heaters
Torpedo
Heater Pump Pressure Adjustment
heatman101
=/=/=/=/=/=/=/=/=/=/=/=/=/=/=/=/=/
Hi,
Here are a couple of tips that I
wrote that tell you how to troubleshoot a Torpedo or Reddy
heater...
Reddy
Heater - Troubleshooting Torpedo Heaters
Torpedo
Heater Pump Pressure Adjustment
heatman101
/[/[/[/[/[/[/[/[/[/[/[/[/[/[/[/[/[/[/[/[
1,190 views
Usually answered in minutes!
I think model 55
Reddy Heater Model M50A, 50000BTU. The machine will start and fire ignites. The machine will blow heat but flames out in about 5-10 minutes. The cloud and fan keep running w/ no flame. If I unplug it and replug it in it will repeat the process.
The same as above
I have a ready heater 110 and it does the same thing worked great then started this out of the blue
Have an RM60 Kerosene Heater. Inconsistant performance. Initially, ignitor would glow, fan would come on, (briefly) but would not fire up, then quickly shut down. Took to a dealer, checked pump pressure, adjusted, and it worked fine, (For about 20 minutes, then it shuts down). Same problem as above. Did a complete tune-up; filters, ignitor, etc.
Any suggestions? (Note: had the unit back to the dealer twice, bring it home, it works great, then reverts back to aforementioned problem(s).
ignites, fan blows but flame only lasts for 20 sec to a minute
heater starts runs for about 5 seconds
reddy heater lights and runs for 5 sec. then stops. have taken apart cleaned, still same, mod. #r55a ser. #5126137
×