Refrigerators Logo

Related Topics:

Goran Popovic Posted on Jan 08, 2012

ALARM AL-15 ON CARRIER REEFER - Carrier Refrigerators

1 Answer

ESTEBAN TORRES

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Mar 19, 2015
ESTEBAN TORRES
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Mar 19, 2015
Answers
1
Questions
0
Helped
2168
Points
1

Hola qtal como estas, tengo un problema con un reffer de carrier modelo thinline con motor resiprocante que me da alarma al 15 y para el equipo no baja ninguna llave solo protege

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

T600R thermo king alarm Code 10 High Discharge Pressure

Helo sir I have a thermo king t600 code 10 or 42or 84 its can ciler
1helpful
1answer

I have a carrier thinline coldroom. It is showing AL 52 - Alarm list full. This error is tripping off power to the compressor and making the unit not to be cold.

Hi,
AL-52 = fuse has blown in unit.
You may just need to get fuse replaced or it may of blown fuse due to a more serious issue.

-I would replace it if i was you it is located outside in the condensing unit or get a tech to replace fuse.
3helpful
1answer

I have a carrier reefer displaying a alarm code 15, not in the manual can someone tell me what it means and what to look for?

ti'm a reefer engineer in iran you have 3 answer:1-the refrigerant in system is low or 2:the control board is failed or 3:the suction line has frost and you must to doing manual defrost in your system,,good luck <sina>
0helpful
1answer

CAN YOU HELP ME WITH AN ERROR COSE ON A CARRIER REEFER UNIT ON A TRUCK?

No, sorry - you will need to contact the manufacturer for any repair or diagnostic information.

Thanks

0helpful
1answer

TRUCK REEFER UNIT ERROR CODE A20

Please use the "continue with this expert" option and explain with greater detail your problem.

Please include Make & Model number of your refrigerator you are getting the a20 error from... and what symptoms you are experiencing for a more comprehensive answer.

Thanks!!
0helpful
1answer

I have a carrier reefer trailer phonix ultra xl that at 25 degrees the low side drop in to a vacuum

Check for dirty evaporator coil, restricted liquid line filter, or defective expansion valve.
Not finding what you are looking for?

2,178 views

Ask a Question

Usually answered in minutes!

Top Carrier Refrigerators Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Carrier Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...