Anonymous Posted on Nov 06, 2011

I have an Atwood water heater G6A-7E, heater heats up but no hot water flow after 15 seconds...Flushed system with water and air, put water to it and the hot water flow stops after a few seconds....

1 Answer

Mike Butler

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • RTO Master 6,674 Answers
  • Posted on Nov 12, 2011
Mike Butler
RTO Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Aug 14, 2008
Answers
6674
Questions
10
Helped
2892867
Points
19845

First check that any by-pass valves are in proper position. Remember, cold water has to enter in bottom fitting at back of tank, and hot water comes out at top fitting. Thus any valves that may be there, need to be in open position, and any valve between those 2 lines will need to be closed. If all valves are in proper position and working as they should, I would suspect you have a faulty check valve between top (hot) line fitting and tank. One easy way to check that before replacing it, would be to shut incoming water source off, whether running off pump or hose attached outside. Then relieve all pressure in system by opening taps until all pressure is gone. Now, go outside and open pressure relief valve carefully ( in case it's hot ) and make sure pressure is relieved there as well. Now, carefully hold pressure relief valve open while you have someone turn water back on, and see if you get good flow from pressure relief valve. If you get good pressure coming out of there, that tells you your tank is getting full, and you have water coming in as needed, so problem has to be on hot side ( top fitting ) and/or onward from there, which would be check valve fitting at top next to check. Remove the check valve and If you don't have a new check valve to try it, just put a short galvanized 1/2" pipe nipple in there for now if needed and that should do it, just attach your fitting directly to nipple. Before you do this, make sure you have removed all aerators etc on taps that may be plugged and tested pressure that way as well just in case. I have seen all of them plug up at same time before. If you remove them and get good pressure, then problem solved.

  • 8 more comments 
  • Anonymous Nov 12, 2011

    Hi Mike, thx for the info...did do all as said, even took off hot water line from tank and put a pocket screw driver in the outlet side and felt nothing....all valves in correct position, put water to system and within 15 seconds flow from hot side stops...Do you have the part number to the check valve...I have been looking online and can't find any information on the check valve...I have my orginal owners manual and with blowup view of all parts and no check valve....next step would be to call Atwood direct... Dennis

  • Mike Butler
    Mike Butler Nov 13, 2011

    Something weird here, so let's get you through this, unfortunately I have to ask a few more questions. First of all, that check valve could be on cold side (inlet) as well due to the fact that there is a few arguments about which one the check-valve should be on, if one used at all. Personally, I would take it out and use 1/2" galvanized pipe nipples into tank, and connect lines directly to that. They cause restriction, as well as problems over time including a buzzing noise when hot water used. They have a plunger and spring assembly inside that over time, or if overpressure happens will fly apart and plunger will block water flow. The plunger looks quite like a golf tee, and often when it flies apart, the plunger stays in the fitting, then lodges itself in a position that it either will cut off flow from hot side or restrict is greatly. Believe it or not, I've seen them break in such a way the plunger part entered the line itself and cause the blockage there. First thing I need to ask I guess is did you get good flow from pressure relief valve when water was on and pressure relief was open? Next, make sure tank is shut off, and drain it. Leave drain plug out and turn water back on, and see if good flow from drain as well, and flush the tank for a few minutes as well while doing this, and watch for anything white plastic, shaped similar to a golf tee, to come out or block hole while flushing. One other thing, could you please explain as best as you can, where the valves are as far as your by-pass goes at back of tank. This may even be easier if we sent pictures etc by e-mail if you can get any. We're not supposed to exchange e-mails, but recently I believe that policy has changed as long as it's o.k. with you, the asker.

  • Anonymous Nov 13, 2011

    Hi Mike, all bypass valves are in the right position, I closed off the suppy to the tabk, out of the tank, opened the pypass and got plenty of flow out of the faucets on cold and hot side...pulled drain plug and turned on water and had great flow out of drain...put plug back in fill tank turn on faucets and hot side flow stops after 15 seconds....doesn't matter if I use house water or pump, same thing happens... have hooked up connections at the bathroom faucet "furthest away" and blowed 40 psi air and then hooked up hose and 55 psi water, all flowed great all the way back and out the drain plug hole...put drian plug back in, fill system with faucets open and flow stops after system is full, acts just like a oneway check valve....turn off house water, open all faucets, purge pressure, go to WH tank and slowley remove drain plug and it has pressure, takes a few minutes to lower the pressure enough to remove drain plug...once the drain starts to flow, you can hear the sound of draining through the faucets...acts just like check valve is flipped to the wrong side....do you know the part number and where to by a new check valve for this Atwood....the water heater itself is in great condiion would like to find this problem....by the way, I am an ASE certified Master Technician for 30 years, but this has got me stumped....

  • Anonymous Nov 13, 2011

    e-mail is ok with me...

  • Mike Butler
    Mike Butler Nov 13, 2011

    You have to remember, when you switch it to by-pass, all that does it re-route cold water around water heater and in through hot line , thus you will probably get good pressure through both for whatever time, as it is now going around water heater. Here's a link to picture of check valves. Do me a favor and describe where valve(s)are located on back of water heater, and by-pass included. I need to know this. (http://www.coastdistribution.com/PDF/Coa... )

  • Mike Butler
    Mike Butler Nov 13, 2011

    2 VALVES, 3 VALVES, 1 VALVE?

  • Mike Butler
    Mike Butler Nov 13, 2011

    they have a few different ways of installing by-pass, so I need to know your configuration to pinpoint problem area.

  • Mike Butler
    Mike Butler Nov 13, 2011

    Not unusual for by-pass valves to screw up and redirect water to where it shouldn't be going at certain times. If you really want to save time troubleshooting, simply remove whatever is required to allow cold line (feed) to go directly in to bottom with nothing else attached ( valves, "t"'s ) and same on hot coming out, remove everything else except straight out to hot. Also remove any fittings, between tank and lines, and replace them both with 2 of 1/2" short pipe nipples. That way you have straight through flow in and out with nothing to cause obstructions.

  • Mike Butler
    Mike Butler Nov 13, 2011

    PS, on that link, scroll down to top of page 294

  • Mike Butler
    Mike Butler Nov 27, 2011

    Any updates for us? Get it fixed/sorted out?

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Atwood g6a 8e

The yellow is caused because the flame does not have enough oxygen. Per your explanation that is being caused because the exaust is not working. Fix the exaust problem and it probably will begin opperating properly.
0helpful
1answer

!990 Bounder By Fleetwood Water Heater is not lighting the propane

Check the gas line orifice for a spider web. Its possible the gas is not able to get past the web.
2helpful
1answer

I have an atwood g6a-7e water heater. The thermal fuse is bad. i need to know what temp and coltage the thermal fuse for this heater is. The numbers on the fuse do not mach any thing on the web.

ANy RV dealer should stock that item . You can temporarily by-pass it for use but be aware you have no safety should a flame-up happen due to spider webs etc getting in to burner tube.
0helpful
1answer

Atwood Water Heater G6A-7E, electronic ignition. Should after the water is heated a small flame is still present at the orifice. It is like a pilot flame. I thought that the electronic ignition was to...

You are correct, there should be no flame after it shuts off. Pull the + wire off at contacts as well and see if flame remains, if it does, the gas valve is faulty (leaking by) and should be replaced.
1helpful
1answer

I have a G6A-7E electronic ignite water heater.

Make sure propane is on and getting to your stove burners ok, first, then try switching it back on. If it fails to ignite, shut switch off and try a couple of times, if still no ignition, get back to me.
0helpful
1answer

Atwood g6A-7E wont turn off keeps heating water till tmp drips

Some dripping at pressure relief valve is normal, but are you saying it continues to run excessively hot? Does water in trailer feel extra hot?
The ECO, and/or Thermostat, should cut the power/flame before it gets too excessive.
0helpful
2answers

ATWOOD WATER HEATER

you will need to have a 115 curent for electric, run a line off the panel box, turn off water to the house drain it down, disconnect the lp gas line and cap it off, remove the water heater, install the new heater run the cold side water to the cold side {blue on the heater} the hot side to the red, take the cover plate off on the water heater run the wires, hook up the groung wire then the red and white wires to the wires comming off the panel box,, fill the water heater with water have a open faucet on the hot side, and bleed the air out, DO NOT TURN ON ELECTRIC TILL THE AIR IS OUT OF TANK AND WATER IS FLOWING THRU COMPLETELY, after you get water commming out of the faucet turn it off and turn the electric on to the water heater ,, wait about 30 min, you will have warm after an hour it will be hot and you are done,, good luck write me if you have questions, [email protected]
Not finding what you are looking for?

189 views

Ask a Question

Usually answered in minutes!

Top RTO Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a RTO Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...