Question about Precor EFX 546i Elliptical Version 4

1 Answer

How to fix Precor EFX 5.17 error code 30 - Precor EFX 546i Elliptical Version 4

Posted by Kim McCann on

Ad

1 Answer

Sportsmith LLC

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Precor Master
  • 918 Answers

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action

  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33

Posted on May 15, 2014

Ad

4 Related Answers

Anonymous

  • 13 Answers

SOURCE: i pulled the plug on my precor efx and now it wont

yes, we can help. 281-469-8506 www.nashsfitness.com

Posted on Aug 10, 2009

Ad

Anonymous

  • 1 Answer

SOURCE: looking for repair manuals and error codes for

Could you please advice about ERROR 29 fo C956i/C966i treadmill.

Posted on Mar 04, 2010

maxtreadmill

John Mazmanian

  • 832 Answers

SOURCE: belt replacement for precor efx 645 verison 1

You may have to purchase the belt from a Precor dealer in you area, if you don't have one then call Precor directly @ 1-800-347-4404 and they will help you. Most of these part have not hit the secondary market yet and Precor pretty much call the shots.

Posted on Mar 13, 2010

ZJLimited

ZJ Limited

  • 17970 Answers

SOURCE: How do I replace the

Check this reference guide in video: Precor+elliptical+trainer+change+belt

Hope helps.

Posted on Dec 28, 2010

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Reset the error code on a precor elliptical


Not familiar with an error 400 - and error 40 is an elevation error - it needs to be addressed(fixed) cannot really be reset otherwise. Check connections and fuses first. If it was recently put together, make sure the data cable was not pinched. If it is battery operated, an error 40 can occur when the battery is low.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

Oct 02, 2014 | Precor EFX 546i Elliptical Version 4

1 Answer

Error 30 on precor 546 efx


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Feb 08, 2013 | Precor EFX 546i Elliptical Version 4

1 Answer

Precore efx 546 error 30


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Jan 31, 2013 | Precor EFX 546i Elliptical Version 4

2 Answers

EFX 5.25. Erro code 30. I had mice chew up the wiring between the two circuit boards. I have replaced the lower board and the wiring harness. Still shows error code 30


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Jan 20, 2013 | Precor EFX 5.25 Elliptical Fitness...

1 Answer

What does error code 30 mean on the Precor efx 576i?


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33

Jul 16, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

I have a Precor EFX 5.17 and received an Error Code 30 while I was using it. What is an Er30 and why did I receive this?


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33

Feb 22, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

Whenever I use our eliptical precor efx, as soon as the elevation starts it says error 45


Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.


Precor Error Code 45

Aug 10, 2010 | Precor EFX 546i Elliptical Version 4

1 Answer

What is error 50 on the precor efx546


Precor uses the same error codes for all of their units. Error code 50 is for excessive brake (eddy current magnet) current.

Mar 19, 2010 | Precor EFX 546i Elliptical Version 4

1 Answer

Error 45 on Precor EFX 546 Elliptical


Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.

Precor Error Code 45

Jul 19, 2009 | Precor EFX 546i Elliptical Version 4

Not finding what you are looking for?
Precor EFX 546i Elliptical Version 4 Logo

938 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

NOEL
NOEL

Level 3 Expert

8549 Answers

Ngoro

Level 3 Expert

2822 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

34939 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides