20 Most Recent Fujitsu 36CS Air Conditioner - Page 8 Questions & Answers

0helpful
1answer

Basic operating instructions fir Fujitsu split system

If you know the model, you can find the correct manual on their website
2/3/2018 1:57:49 PM • Fujitsu Heating... • Answered on Feb 03, 2018
0helpful
2answers
0helpful
1answer

Need to move air conditioner model ASTA30LCC from

you need a 2.5 to 3 inch hole in bottom right corner of head unit If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79
1/29/2018 8:19:09 PM • Fujitsu Heating... • Answered on Jan 29, 2018
0helpful
1answer

I need to get to the water tray of a Fujitsu air conditioner

you're not going to. taking the front panel off does not access the pan. the pan is the actual Styrofoam insulation and it's too risky to remove it for fear of cracking it. what is your problem? If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79
1/24/2018 10:32:00 PM • Fujitsu Heating... • Answered on Jan 24, 2018
0helpful
1answer

I have a reverse cycle 4 year old fujitsu air con and when I turn it on it automatically just blows air not cold air - it seems to divert to sleep almost immediately can u help.

It should still be in warranty as Fujitsu usually goes for 5 years. Get in touch with Fujitsu to find a local warranty agent. There's not enough info in your post for a diagnosis. Are the lights flashing? If so, what sequence are they flashing? Does the indoor unit otherwise work normally in 'fan' mode? What model do you have?
1/16/2018 3:54:07 AM • Fujitsu Heating... • Answered on Jan 16, 2018
0helpful
2answers

FUJITSU AST17RSA-W. Motor stays on when I turn it off.

Sounds like the contactor/relay for the compressor is stuck closed. I haven't got a circuit diagram but if you're lucky you may be able to just change the relay. If it's part of an integrated circuit board you will probably be out of luck as this is a very old model and I doubt that many parts are available.
1/5/2018 2:45:16 PM • Fujitsu Heating... • Answered on Jan 05, 2018
0helpful
1answer

Hi would someone please send me a photo of the outdoor wiring for fujitsu 2410A ?

We need a model for that. It looks like the JCC family or JEC. Do you have it? Even the indoor model would help.
1/5/2018 12:10:07 PM • Fujitsu Heating... • Answered on Jan 05, 2018
0helpful
1answer

Fujistu 12 BTU, model ASY12R, bought in May 2002, after removing the filters and the front facia for cleanup the aircondition is not starting up. The remote is good because I press the start button in

Check that your isolator has been turned back on and that the circuit breaker hasn't tripped. If you have a multimeter or 'volt stick' you can check for power coming in. If you have power, you may have damaged the controller board or receiver board. Check that the receiver board is still plugged into the controller and all other plugs are in the correct terminals and pushed home securely.
1/2/2018 11:16:58 PM • Fujitsu Heating... • Answered on Jan 02, 2018
0helpful
1answer

Fujitsu split system air conditioner is making a rattle sound which is a nnoying and makes it hard to sleep. Anyone know how to fix this problem?

Scroll fan is probably out of balance which can sometimes be fixed by getting it serviced where the fan and internal components are cleaned. If the fan blades have been damaged from someone putting something inside while it is running, you will need a new scroll fan. The fan motor could also have bad bearings.
1/2/2018 11:13:14 PM • Fujitsu Heating... • Answered on Jan 02, 2018
0helpful
1answer

Fujitsu Aircon model AST24PBA-W has green Timer light continuously flashing and red Operation light giving 5 flashes. Outside unit fan will not run. What does this code indicate has failed?

Most likely a faulty fan motor. You will need a tech to diagnose correctly as this uses a DC motor which has a circuit board inside so has very specific tests. Other possible faults for this code are compressor rotation error, CT abnormal or current trip all of which will need a tech to diagnose.
1/2/2018 11:10:48 PM • Fujitsu Heating... • Answered on Jan 02, 2018
0helpful
1answer

Fujitsu ASTG18KMCA. Remote control - on/off, powerful, two arrow temp buttons, 10C button. Screen display shows Mode Heat. Can't find instructions to change to Cool.

Pressing the Mode button will change what mode it is in. If it doesn't then either the remote or receiver is faulty.
1/2/2018 11:04:39 PM • Fujitsu Heating... • Answered on Jan 02, 2018
0helpful
1answer

Removal of cover from ASTA09LCC fujitsu air con

First remove the filter cover by lifting it up then sliding down the retaining tabs on each side next to the hinges. Next pull out the filters. Then remove the screws from the front panel remembering that there is one screw behind the terminal cover. Then you need to use a flat blade screwdriver to lift the three clips holding the top rear of the cover to the rest of the casing at the left, middle and right (see photo) then pull the cover forward. I'm not certain but from memory, you might have to unhook the head unit from the bottom of the backing plate for this to come off. Be careful you don't break the cover while doing this. You may need to get a ladder to see the top clips. dsc_4064-ixatf3mjftnjei4yjsideqpx-3-0.jpg dsc_4064-1-ixatf3mjftnjei4yjsideqpx-3-1.jpg
1/2/2018 11:03:27 PM • Fujitsu Heating... • Answered on Jan 02, 2018
0helpful
1answer

Have ASTA 12LCC model, installed last Aug. Wont

Try the manual switch just under the filter cover near the wire terminal cover. If that works, you probably just need a new remote. If not, the indoor controller is probably faulty.
12/26/2017 12:33:45 AM • Fujitsu Heating... • Answered on Dec 26, 2017
0helpful
1answer

My fujitsu mini split is tripping the circuit breaker on heat mode after a few minutes of operation. the a/c works fine. It makes a lot of noise just before tripping

If I had to guess you have a bad reversing valve. valve sticking, compressor not being able to pump refrigerant, then drawing high amps, overheating and tripping the breaker. If you have tools and experience, try tapping on the valve gently to free it up while switching. If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79
12/24/2017 1:34:12 PM • Fujitsu Heating... • Answered on Dec 24, 2017
Not finding what you are looking for?
Fujitsu 36CS Air Conditioner Logo

56 questions posted

Ask a Question

Usually answered in minutes!

Top Fujitsu Heating & Cooling Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66827 Answers

Are you a Fujitsu Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Fujitsu Heating & Cooling

  • Fujitsu Heating & Cooling

Most Popular Question

eee code

  • Heating & Cooling
Loading...