20 Most Recent Paragon 8145-20 Defrost Timer - Page 8 Questions & Answers

0helpful
1answer

Where can I find the

Open following link to identify timer and download manual
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

1) Paragon 4000 series uses X2772 tripper.

2) Internet search for tripper reveals some sources selling set of trippers for $50.
Paragon is no longer making timers or parts, except for defrost series timers.
4000 series is not a defrost timer, which explains high price for trippers.
Some sources might still have X2772 tripper at lower price.

3) Other companies are still manufacturing some Paragon timers for niche sales.
Certainly the Paragon line is still active although names and numbers will probably change over next few years.

4) I cannot specifically identify 4001-0g, and the 'g' suffix does not show in sell sheet
http://waterheatertimer.org/pdf/Paragon-4000-24hr-7000-7day.pdf

5) Replacement timer for 4001-00 is Intermatic T101
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

6) New T101 from Amazon is $45.00 with free shipping
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.
3/23/2011 3:53:21 AM • Paragon Hardware... • Answered on Mar 23, 2011
0helpful
1answer

The 4004-20 timer began humming

Paragon 4004-20 is DPST mechanical timer with 240V clock motor
http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx

I'm guessing that clock motor is source of noise.
If timer is keeping good time and dial is not slowing at tripper points then timer is basically sound.
Turn power OFF and spray WD40 or put a bit of white grease on the gears.
The noise might also be the timer mechanism vibrating in the box... see if snapping out the mechanism and putting it back makes a difference ... you might have to push sides of box inward to hold mechanism tighter.

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.
1/28/2011 3:12:21 AM • Paragon Hardware... • Answered on Jan 28, 2011
0helpful
1answer

On parAGON 7000 MODELS

1) Paragon 7000 series clock motor is terminals A and B
http://waterheatertimer.org/Paragon-timers-and-manuals.html#7000

2) If you have EC7000 digital timer, then wiring is different.
With EC7000 120V, clock motor is terminals 1 and 4 with jumpers added between 1 & 2, and between 3 & 4.
With EC7000 240V, clock motor is terminals 1 and 4 with jumpers added between 2 & 3.

3) Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.
1/21/2011 11:59:44 PM • Paragon Hardware... • Answered on Jan 21, 2011
0helpful
1answer

I have a Paragon Timer

Paragon does not show 47017 timer.
So sight-identification is next.

Here's a link that shows photos of Paragon timers:
http://waterheatertimer.org/Paragon-timers-and-manuals.html
I added manuals next to each of the Paragon products.
1/11/2011 7:20:27 PM • Paragon Hardware... • Answered on Jan 11, 2011
0helpful
1answer

I need trippers for an

I don't recognize Paragon TC-2.
http://waterheatertimer.org/Paragon-timers-and-manuals.html

Intermatic cross reference does not have that model number either.
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx

Paragon sent e-mail last month saying they were no longer making timers and parts, except for defrost timers. Your water heater timer is not defrost timer.

Here is a wide selection of water heater timers, electro-mechanical and digital:
http://waterheatertimer.org/Boxtype.html
Manuals and wiring diagrams are shown for most products on page.

I recommend simple 240Volt Intermatic WH-40 for price and reliability. Drawback is minimum 1 hour on-off.
Or Intermatic T-101 for 120Volt heater or T-104 for 240Volt heaters sold at Lowes.
Intermatic trippers and motors are available and interchangeable, and are made of steel.

Some new timers are made with plastic parts:
GE 15207 is universal 120V 240V and sold at Home Depot.
Tork has new universal electro-mechanical timer, TU-40 for 120 and 240 applications

I use GE 15070 in-wall timer from Home Depot for my water heater because I change times frequently and try to shave every dollar:
http://waterheatertimer.org/Compare-13-electric-water-heater-timers.html

Add a comment if you need more help.

You can also take advantage of fixya phone support.
Fixya expert will walk you through any problem for a price.
12/23/2010 5:29:24 AM • Paragon Hardware... • Answered on Dec 23, 2010
0helpful
1answer

CAN YOU SHOW ME PARAGON TIMER 8045-21 THE WIRING

HI, I RECENTLY SAW A LISTING ON EBAY FOR THIS ITEM. THE PHOTO SHOWS THE WIRING DIAGRAM.
HERE'S THE LINK.
http://cgi.ebay.com.au/ws/eBayISAPI.dll?ViewItem&rd=1&item=110619214541&ssPageName=STRK:MESE:IT#ht_843wt_1139
12/2/2010 4:11:47 AM • Paragon Hardware... • Answered on Dec 02, 2010
0helpful
2answers

Lost pcs.that turn on and

If I understand correctly, you need tripper pins for a Paragon timer
http://www.paragontimecontrols.com/parts_accessories.htm
At page bottom is a chart with model number and the tripper required
http://waterheatertimer.org/Paragon-timers-and-manuals.html

The two links above help you identify your timer model and identify the tripper.
After identifying tripper number, you have to do a google search for that tripper number

So, if you need more help, please answer back and we'll find the right timer and pin

If you have Intermatic timer, then you can buy pins at Grainger
http://www.grainger.com/Grainger/INTERMATIC-Timer-Tripper-2E054?Pid=search
10/21/2010 11:29:01 PM • Paragon Hardware... • Answered on Oct 21, 2010
0helpful
1answer

I have a model 7005

72d1511.jpgParagon 7000
Paragon 7005 is a heavy duty 7-day mechanical timer that can handle 4 loads. It is DPST. One of two wiring diagrams applies to this timer:
1d6e8ec.jpgThe question is the the timer clock motor is 120V or 240V?

36b7dc9.jpgParagon EC 7000 is a 7-day digital timer with 16 set points per week
Manual for EC7000
http://waterheatertimer.org/pdf/Paragon-EC7000-wire.pdf

Please re-post your questions as you start sorting out which timer you have.
Paragon is improving their site so there is less confusion over model numbers and functions. but information about the 7000 are still sketchy.
10/16/2010 12:29:10 AM • Paragon Hardware... • Answered on Oct 16, 2010
0helpful
1answer
0helpful
1answer

Need instrutions manual for the EC 4005 timer

The link below will take you to the EC4000 series Paragon manual.

http://www.paragontimecontrols.com/manuals/paragon/110-668B.pdf

This link will take you to EC4000 series cut sheet that shows specifications and wiring diagrams.

http://www.paragontimecontrols.com/SellSheets/Paragon/EC4000%20Series.pdf
5/4/2010 5:26:08 PM • Paragon Hardware... • Answered on May 04, 2010
0helpful
1answer

I have installed a paragon timer model 7007-00 a

Check the voltage you are supplying to the timer. The voltage should read within +/- 10% of 120VAC. If your voltage is out of this range (110VAC to 130VAC) the motor on the timer will run too fast or slow.
3/18/2010 3:27:28 PM • Paragon Hardware... • Answered on Mar 18, 2010
0helpful
1answer

I have a Lithonia dusk to dawn flood light that's brand new there's also an on off switch. What does the on off switch control and for dusk to dawn should it be on or off?

  • When the switch is ON, the light operates in dusk-to-dawn mode. In this mode, the light automatically turns on at sunset and turns off at sunrise. When the switch is off, the light stays off.
4/18/2024 7:13:42 PM • Hardware &... • Answered 20 hours ago
0helpful
2answers

Grasslin QE7+ water heating timer dial problem

motor or gear failure
3/12/2024 10:39:33 AM • Hardware &... • Answered on Mar 12, 2024
0helpful
1answer

Electrolux KOAAS31WX oven timer has maximum 20 minutes.

It sounds like the button contacts aren't making good contact. If you can get behind them you can spray them with electrical switch cleaner. ..
3/2/2024 6:36:01 AM • Hardware &... • Answered on Mar 02, 2024
0helpful
1answer

How do I reset the ellis geyser timer to save electricity

Press P (program )on the timer and display will show then change the desired day, time and minute using the D+, H+ and M+ buttons. Press P again to set up another program and repeat the second step as above
2/26/2024 7:44:48 AM • Hardware &... • Answered on Feb 26, 2024
0helpful
1answer

How do I program outdoor timer model 28486

Clear memory by pushing the reset button on the timer then reprogram using your current schedule when you want the timer to go off/on. Use the day and clock buttons for this then press enter
2/26/2024 7:35:43 AM • Hardware &... • Answered on Feb 26, 2024
0helpful
1answer

Should the utiletech 24 hour manual timer make a humming noise while on?

No, the timer should not make any noise. The noise should be a result of loose connections which cause arcing, which can make a humming or buzzing sound. If you find that you still notice the sound, even when the main breaker is off then the problem is not electrical in nature.
2/26/2024 5:38:54 AM • Hardware &... • Answered on Feb 26, 2024
0helpful
1answer

Micromark MM 9565 Timer. How to set up the timerMM9565micro Mark timer

Question edited for clarity and add a header in order with spaces and CAPS. It appears Micromark got out or the timer business. There is a similar one in another Fixya post, and a link to them. https://www.google.com/search?q=Micromark+MM+9565+timer ..
2/19/2024 10:55:33 PM • Hardware &... • Answered on Feb 19, 2024
Not finding what you are looking for?
Paragon 8145-20 Defrost Timer Logo

92 questions posted

Ask a Question

Usually answered in minutes!

Top Paragon Hardware & Accessories Experts

Brad Brown

Level 3 Expert

19187 Answers

Cindy Wells

Level 3 Expert

6688 Answers

john h

Level 3 Expert

29494 Answers

Are you a Paragon Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Paragon Hardware & Accessories

  • Paragon Hardware & Accessories

Most Popular Question

paragon 8145 20 d frost o matic

  • Hardware & Accessories
Loading...