The outside and inside coils may need cleaning. Clogged coils cause excess pressures and heat of the freon that can cause safety switches to shut er down. Eveen a faulty power relay in the outside unit.Otherwise you may need a serviceman to locate the cause.

LG LS-L1210CL... | Answered on Jan 28, 2012


I do know that the owners manual should show you what each and every code means? Some times the manufacture will paste a strip located on the panel of the indoor unit showing what each code means. If not, I would contact the factory on this. I know on Bryant, Mitsubishi splits, Day and night, (Bryants), Tranes, Lennox and most all others, do show in the manual and on the unit behind the panel. Try looking for them there.
Sincerely, shastalaker7

LG LS-L1210CL... | Answered on Oct 27, 2011


Has a problem in the internal sensor unit now who is not know, has three interventions However an N sensor and started tried to see who it is.

LG LS-L1210CL... | Answered on Oct 08, 2011


checking out the capacitor that goes to wire the fan and if it is OK then he NEW fan motor.

LG LS-L1210CL... | Answered on Oct 08, 2011


There can be multiple reasons for this. Is the outside condensing unit running? and this is assuming that the wall hung AHU is blowing? Also is there any tripped breakers/ burnt fuses, etc.? With a few more variables answered we may be able to come up with the solution to your problem.

LG LS-L1210CL... | Answered on Sep 23, 2011


Assuming you have the proper equipment to service the unit the best option is to weigh in the charge- superheat/subcooling calculations fly out of the window on mini-splits and the frustration and time spent trying to achieve proper refrigerant balance is more pricy than recovering the charge and reweighing it into the system. If you are not experienced in this field attempting to do so can cause major damage to very expensive equipment.

LG LS-L1210CL... | Answered on Sep 22, 2011


A CH46 error indicates the low side sensor or suction line sensor is defective and not within acceptable parameters. It may be loose or off or simply bad.

LG LS-L1210CL... | Answered on Sep 13, 2011


TRY SHUTTING THE BREAKER OFF, FOR ABOUT 10 MIN . THERE SHOULD BE A LITTLE HOLE IN YOUR REMOTE , USE A PAPER CLIP TO PUSH IT (LIGHTLY !)THAT WILL RESET THE REMOTE.. GOOD LUCK AN VOTE IF I WAS OF HELP.. YOU KNOW I DO THIS 4 FREE RIGHT ?

LG LS-L1210CL... | Answered on Sep 10, 2011


It has lost its refrigerant charge again. Have someone find and fix the leak before recharging or it will just leak down again.
Hope this helps

LG LS-L1210CL... | Answered on Sep 09, 2011


The compressor is probably tripping on high discharge pressure due to the slow fan rotation. That can be caused by a weak capacitor or the fan motor failing. The capacitor can be checked with a multimeter that has the capacitor check function. The capacitors are inexpensive but the fan motor will be another story. You should also check the voltage going to the fan motor.

LG LS-L1210CL... | Answered on Sep 02, 2011


The "head unit" mounted on the wall shows you the current room temperature. On your remote it shows what temperature you are trying/want to achieve.

LG LS-L1210CL... | Answered on Aug 13, 2011


This is fine. its alright for this to happen.. just keep your filter clean and all will be fine. Hope this helps let me know Jon

LG LS-L1210CL... | Answered on Aug 07, 2011


Does da aircon have a heater

LG LS-L1210CL... | Answered on Jul 26, 2011

Not finding what you are looking for?
LG LS-L1210CL Mini Split Air Conditioner Logo

342 questions posted

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Marvin
Marvin

Level 3 Expert

85239 Answers

Steve Oakes
Steve Oakes

Level 2 Expert

234 Answers

Muntejaya Ginting
Muntejaya Ginting

Level 3 Expert

10422 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

LG Heating & Cooling

  • LG Heating & Cooling

Most Popular Question

uf running capacitor will ok 1 5 ton

  • Heating & Cooling
Loading...