20 Most Recent Hayward H Series Induced Draft Abg 100,000 Heater Questions & Answers


H100ID fan was stuck. Manually turned fan until it worked loose and sprayed silicone lubricant dielectric lubricant on spindle. Once free turning, it fired right up. We didn't use it all last summer so it probably just got frozen from bugs and such. If it doesn't turn, entire system wont fire.

Hayward H Series... | Answered on Aug 23, 2019


no description of issue. good luck

Hayward H Series... | Answered on Jul 26, 2019


if you dont have enough flow, the heater wont run. if you have a VS pump and run it at minimum speed to let heater work, the heater wont cool properly and may damage components.

Hayward H Series... | Answered on Apr 16, 2015


There are several things that can cause this symptom. If you have a volt/ohm meter and call the Hayward technical support at 908-355-7995 they might be able to help you figure this issue out. I hope this helps.

Please vote on this answer. Thank you.

Hayward H Series... | Answered on Oct 18, 2012