20 Most Recent Aqua Flo Aquaflo Flo Master Xp2 Spa Pump 1.5 Hp Two Speed Questions & Answers

0helpful
1answer

Changing hot tub pump flo

DO NOT PLAY AROUND WITH THE WIRING OF THIS 2 PEED. you can cook the motor in just a few seconds != junk yes WHITE is common RED is low and BLACK is high A picture of the connections in the back of the motor is needed for further assistance Jay the pool pump repair guy in longwood Florida.
6/20/2018 6:36:47 AM • Aqua Flo Aquaflo... • Answered on Jun 20, 2018
0helpful
2answers

Power trips out when jets are switched on

I'm going on somewhat limited information here not knowing if the tub is newly installed or if this is a spa that has been working in the past and just started doing this. It would be helpful to know if this is a recently installed pump as well. That said here are a few things to check. If it's a new install: Your electrician has more than likely wired the spa incorrectly. Be sure that the spa pack has 220V going into the pack and that the GFCI is wired correctly.If it's an old spa with a new problem: A lot of times a bad heater element can cause a spa to trip the breaker. If you have a bad element the spa will operate normally for about a minute when you turn the power on, then trip the breaker as soon as the heater kicks in. If it only trips the breaker when the pump is turned on to high speed, more than likely there is a problem with the wiring of the pump or the relay on the pump itself.
3/24/2018 5:02:59 AM • Aqua Flo Aquaflo... • Answered on Mar 24, 2018
0helpful
1answer

Hot tub pump stops and control panel says there is a flo problem

Yes a pump does have a thermal cut out. When the motor gets too hot the thermal cut out will activate and the pump won't restart until the motor has cooled. If you were an electrician, or highly confident/competent with electrics, you could test the motor with a volt meter. Run the spa and as soon as the pump stops running, check the voltage at the pump. If there is voltage at the pump, then the thermal cut out on the motor has activated. Do not try checking this yourself if you're not competent to do so. You could also do the same test at the spa pack if it's easier to do so, just locate the output to the pump. What spa and which spa pack have you got? Cheers, Ian.
3/24/2018 5:01:42 AM • Aqua Flo Aquaflo... • Answered on Mar 24, 2018
0helpful
1answer

My hot tub is leaking from one of the pumps. how do i change the pump?

Sounds like you need a new Mechanical Seal for the wet end. Pretty simple job to change the seal kit. It is also a lot cheaper to do that than purchase a new pump. US Parts Center
1/20/2018 3:06:52 AM • Aqua Flo Aquaflo... • Answered on Jan 20, 2018
0helpful
1answer

Remove a wet end from a aquaflo xp2 spa pump motor how do I do this

There are 4 bolts that go all the way through the motor and thread into the wet end. The first place to start it to remove the face plate of the wet end exposing the impeller. The impeller is threaded onto the shaft of the motor. Take a big flat head screw driver and put it onto the end of the shaft of the motor and hold it tightly so you can unthread the impeller off the shaft of the motor. Unthread those four bolts that go all the way through the motor. You are done at this point. US Parts Center
1/20/2018 3:03:26 AM • Aqua Flo Aquaflo... • Answered on Jan 20, 2018
0helpful
1answer

I have an appolo spa explorer model...bought it

you must have a small pump call laing if you do, air picket inside the plumbing try to turn both pump on high and wait few minutes if doesn fix try to loose the nut just a little bit with the breakers off and let the air go out. try one more time. if doesn work turn on high both pump and touch if they are working then a impeller may be broken inside one of them try to turn each one separate to find wich one as t he broken impeller.
12/5/2017 8:09:31 AM • Aqua Flo Aquaflo... • Answered on Dec 05, 2017
0helpful
1answer

Wire for 02115000-1

wiring diagram should be on the side of the motor
8/30/2014 2:29:31 AM • Aqua Flo Aquaflo... • Answered on Aug 30, 2014
0helpful
1answer

I installed a new pump motor. It has power, lights are working but jets are not. What wires could be wrong - I don't have clear red, black, white and green wires. The spa is a freeflow passport spa.

there should be a wiring diagram on the side of the motor make sure if you are running 120 volt you changed the shunting on motor or might have hooked up incorrect if no info call a professional
4/19/2014 3:12:47 AM • Aqua Flo Aquaflo... • Answered on Apr 19, 2014
0helpful
1answer

The pump will rum on first stage but is tripping power on second speed

Hi Martin, Thanks for the question. It sounds as though the pump relay or the pump itself is fried. I would recommend calling a service technician. If you know how to check voltage yourself, use a multimeter or (fluke meter) to test the voltage between the pump relay. if that reads normal then test the pump itself. It could be the difference between buying a new pump, or a new spa pack. I hope this helps, Thanks again!
2/18/2014 8:26:41 PM • Aqua Flo Aquaflo... • Answered on Feb 18, 2014
0helpful
1answer

I have a aqua flow xp2 and does not work i have

if its a 220 unit then you have a ground issue..if its a 2 speed 110 unit then the switch may be stuck inside..
1/10/2014 7:35:21 PM • Aqua Flo Aquaflo... • Answered on Jan 10, 2014
0helpful
1answer

My new flo-master xp2 spa pump will not engage the low speed. The hi speed (jets) works fine but the low speed doesn't engage. I just hear a clicking and nothing comes on.

if you had ice in it and it was powererd up.. you may have burned out the start capacitor or even the start windings..why was it iced up while working on it..it should have been freewheeled by hand before startup..I just got a tub in here.. had to wait 6 days for it to thaw out..(sign of good insulation) we just ran it for the first time yesterday..got some seals to replace and some switches to repair..
1/8/2014 10:50:17 PM • Aqua Flo Aquaflo... • Answered on Jan 08, 2014
Not finding what you are looking for?
Aqua Flo Aquaflo Flo Master Xp2 Spa Pump 1.5 Hp Two Speed  Logo

131 questions posted

Ask a Question

Usually answered in minutes!

Top Aqua Flo Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

David Spradling
David Spradling

Level 3 Expert

13524 Answers