Will a flow switch stop the tub of any operation
Is the board getting power, is the control lighting up?Do you see any error codes on the top side control? Improper flow will give you an error code, caused by flow issues or a faulty flow switch. Make sure all gate valves are open and the water can flow freely.If not then check your Hi Limit sensor. This is the overheat safety sensor if it fails the tub will not function at all.
The spa won't shut off. It keeps overheating
Check the filtration cycle. I have seen several hot tubs over the years where the owners have accidentally changed the filter cylce duration without realising.
If the filter cycle duration is set too long it may/will overheat.
It's also possible that you may also have a problem with the PCB. This would need to be checked by a spa technician who knows the system well.
Regards,
Ian.
http://hottub.synthasite.com
Foam in hot tub cover broke
The foam in there is available at most insulation or drywall supply houses. It is used for insulating concrete walls, the cover is probably 3 inches thick so you may have to buy 2 sheets to get the thickness you want. The only issue is the cost of the foam may not be much less than a new cover.
My dream maker spa does not work. there is
I have the same problem with a one week old x400. It was working fine last night but about 8 hours later water temp has dropped 4 degrees and the pump will not turn on, I can hear the relay in the control box make a ticking sound when I press the pump icon on the control center but the pump does not start. Is there a fuse in the control box?