Its giving an error code CH 02

You have to try resetting the system. First turn the breaker off for the condenser and wait about 20 seconds. After you turn it back on the system should reset Air Conditioning Tamarac
8/15/2016 10:43:02 AM • LG LP1200DXR... • Answered on Aug 15, 2016 • 1,336 views
0helpful
1answer

CH 02 error code

Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace sensor.
2/9/2016 6:52:45 AM • LG LP1200DXR... • Answered on Feb 09, 2016 • 475 views
0helpful
1answer

How do you drain the water?

there should be an upper drain and lower drain in the back bottom of the unit unplug the drain plug and voila!!
9/9/2015 11:08:16 AM • LG LP1200DXR... • Answered on Sep 09, 2015 • 277 views
0helpful
1answer

Is it safe to leave on all day with no one home i would like to leave on for my cat

Depends on where you live and how much you care about your cat. I wouldn't.
6/11/2015 1:00:18 AM • LG LP1200DXR... • Answered on Jun 11, 2015 • 87 views
0helpful
1answer

It shows the FL error

tip the zircon back a little bit and water will pour our. I did this because i had the same problem. This solves it
12/23/2014 8:51:47 AM • LG LP1200DXR... • Answered on Dec 23, 2014 • 5,453 views
0helpful
1answer

Can not turn on

11/22/2014 4:10:16 PM • LG LP1200DXR... • Answered on Nov 22, 2014 • 184 views
0helpful
1answer

I have a LG LP1200DXR and IT doesn't cool and it hasn't asked to drain in alot of months

If it hasnt been drained then there is likely a float switch that is keeping the compressor from running so that it doesnt overflow.
8/19/2014 6:00:06 PM • LG LP1200DXR... • Answered on Aug 19, 2014 • 357 views
0helpful
1answer

My portable Air conditioner doesn't cool cold air anymore

Wrong site for that Just a chat room
8/22/2014 6:00:14 PM • LG LP1200DXR... • Answered on Aug 22, 2014 • 585 views
0helpful
1answer

What to do when portable airconditioner overheats

portable air conditioner need clean condenser .
7/16/2014 11:50:51 AM • LG LP1200DXR... • Answered on Jul 16, 2014 • 165 views
0helpful
1answer

Oil burner beckett Burner will not fire up after adding fuel

Check your fuel filter & purge the pump
12/16/2013 8:18:30 PM • LG LP1200DXR... • Answered on Dec 16, 2013 • 97 views
0helpful
1answer

Oil burner beckett/ Ran out of fuel put fuel in Burner will not fire up?

Purge the pump.
12/16/2013 8:18:06 PM • LG LP1200DXR... • Answered on Dec 16, 2013 • 98 views
0helpful
1answer

I have the LG LP1200DXR and it is leaking near the

All air conditioners collect condensate. It has to drain somewhere. Try connecting tubing to the drain hole or port. In order for air conditioners to remove heat from a space, they also remove humidity, which is water vapor in the air. Like placing a cold beverage in a warm room, it will form condensate (water) around it. The water that you were trying to drain out already leaked out. This is a normal thing for condensation to form when cooling. The condensate needs to be emptied regularly or piped with flexible tubing to a window or plumbing.This is the same as water dripping from your car while the A/C is on.
6/10/2015 12:18:19 PM • LG LP1200DXR... • Answered on Jun 10, 2015 • 828 views
0helpful
2answers

Ac unit keeps reading fl

After reading over the Owner's Manual for your unit, I wonder if you are operating it in the Cool & Dry Mode. If that's the case, the dehumidifier is in operation, which would account for having to drain the unit every 2 to 3 hours. Ideally, the Cool and Dry Mode should only be operated for about an hour, when the unit is first started . Removing the humidity will allow the AC function to cool more effectively. But, it is not necessary for it to remain in Cool & Dry mode all the time. Because the AC itself unit will remove some humidity too.

Hope this helped you to troubleshoot and solve the issue of having to drain the unit every 2 to 3 hours
5/31/2013 10:32:07 PM • LG LP1200DXR... • Answered on May 31, 2013 • 1,547 views
0helpful
1answer

Low charge

It still has a leak, just a small one. This needs to be found and fixed. Check all flexible connections first, look for signs of oil, it comes out with the refrigerant.
9/7/2012 8:38:43 AM • LG LP1200DXR... • Answered on Sep 07, 2012 • 84 views
0helpful
1answer

Como debo controlar el bote

No es necesario a?adir agua al tanque de aire acondicionado port?til. Cuando la unidad funciona, se genera es el agua de la condesation en la habitaci?n. La adici?n de agua, significa que usted tendr? que darin el tanque con m?s frecuencia.

Espero que esto
te ayud? y gracias por elegir FixYa.
9/22/2011 8:05:32 PM • LG LP1200DXR... • Answered on Sep 22, 2011 • 306 views
0helpful
1answer

My LG LP1200DXR Portable Air

Actually, your unit was not designed for continuous draining. It needs water in the tank to help cool the coils. I'm sort of surprised that the unit hasn't stopped cooling or hasn't overheated. Since you haven't seen any water in the drain tank you have, it may have pasted the point of no return. Disconnect the hose, reinstall the drain plug and hope that you have to start emptying the tank again, soon.

Hope this helped you and thanks for choosing FixYa.
8/20/2011 2:30:53 AM • LG LP1200DXR... • Answered on Aug 20, 2011 • 1,249 views
0helpful
1answer

LG 1210 BXR portable air

In AC mode, the unit still has some dehumidifying properties. So, it may be that there is more humidity in the air this Summer, than in prior years. Having to empty the tank every 24 hours is not unusual. Be sure that the air intake filter is clean & check the exhaust hose for obstructions.

Hope this helped you & thanks fr choosing FixYa.
8/13/2011 1:16:07 PM • LG LP1200DXR... • Answered on Aug 13, 2011 • 854 views
0helpful
1answer

Only warm air blows out

clean the unit,
7/31/2011 11:41:47 PM • LG LP1200DXR... • Answered on Jul 31, 2011 • 333 views
0helpful
1answer

Internal discharge blower not spinning

Check the fan capacitor.bobicehouse_36.jpg
7/22/2011 4:16:53 PM • LG LP1200DXR... • Answered on Jul 22, 2011 • 78 views
0helpful
1answer

Why does the compressor on my lg 12000 unit

Hi,
Either the unit is low on freon or the freeze sensor is bad...sensor or control board that is....
Anyway the coil is either getting too cold or the unit thinks the coil is too cold and is shutting down...

You will have to troubleshoot the exact problem or have someone check it for you...

heatman101
7/17/2011 5:13:02 PM • LG LP1200DXR... • Answered on Jul 17, 2011 • 1,181 views
Not finding what you are looking for?
LG LP1200DXR Portable Air Conditioner Logo

85 questions posted

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

MattS1978

Level 1 Expert

7 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...