Goldstar DH5010B Dehumidifier - Page 4 - Answered Questions & Fixed issues
The back is icing up,
there are a few things that could cause this. first check that if there are any filters, they are clean. next, check that the front coil is clean. you will have to open the case to check this. another thing that could cause this is the room temperature is too cool or possibly that the humidistat is up all the way in a cool room. if it is not any of these then a freon leak may have developed and the unit is low on freon charge. check all of these the let me know the results.
5/14/2011 4:46:01 PM •
Goldstar...
•
Answered
on May 14, 2011
•
46 views
Is it ok to use
Of coarse it is. Many newer homes with energy efficient heating are built so tight that moisture from showers and cooking builds up to un-acceptable levels.
2/5/2011 11:08:00 PM •
Goldstar...
•
Answered
on Feb 05, 2011
•
66 views
Goldstar dehumidifier model DH305Y6
I have a Goldstar dehumidifier, Model DH305Y6. I bought it about 5 years ago at a local Walmart. During the summer I run it in the basement, here in south-central Pa. When it was brand new it worked very well, for about 2 yrs. Then it began turning on & off very irregularly. At first I thought it was the sensor on the front of the coils. So I moved it to the lower left side of the coils, and had the same results. The other day the water heater in the basement developed a leak. About 300 gals. of water covered the floor. After sumping/wet-vac'ing down to a wet carpet, I pulled out the dehumidifier and plugged it in,(the filter was cleaned before put away last summer). It began its on/off cycling again. It runs for about 2-3 mins., then shuts off for about 5-10 mins. So, I took the On/Off switch apart and read the resistance. It read 48k, for the 50k switch. I turned the switch all the way left to all the way right and it went from 48k, down to about 8k. The two wires to the switch were attached to the #2 and #3 poles,(only 3 poles). I did some testing, then removed the wires and re-soldered them to the #1 and #3 poles. I put everything back together, and now it works. It runs constantly, but it works/runs just fine. I need to get the basement dry, so I will let it run until the job is done. In the Spring I will get a new 50k potentiometer,(on/off switch), and see if that works. I will post results if I remember to.
2/3/2011 4:54:33 AM •
Goldstar...
•
Answered
on Feb 03, 2011
•
272 views
Model DH305T7. Blower fan
Hi,
the bearing have siezed up on the fan... some WD-40 and then some oil may get it going agian...
heatman101
8/29/2010 9:35:16 PM •
Goldstar...
•
Answered
on Aug 29, 2010
•
102 views
I want to clean filter
remove water bucket from cabinet. filter is above,pull down fitter will come out wash with soft brush and warm soapy water slide filter back in groove above. waa laa.....!
12/1/2009 2:21:30 PM •
Goldstar...
•
Answered
on Dec 01, 2009
•
48 views
My Goldstar Dehumidifier keeps cutting off even
A few things you could try are to make sure the float isn't covered in gunk and moving sticky-like, make sure air filters are clean and the compressor isn't overheating, and make sure the humidistat (probably a knob that says drier with arrows) isn't turning the machine off because it's reached the set level.
11/25/2009 4:41:37 AM •
Goldstar...
•
Answered
on Nov 25, 2009
•
98 views
Ice forms on the top of the dehumidifier.
normally the problem is either your evaporator is dirty or may be your systems isover charged,
you need a competent person to cean your systems and check gas pressures on the discharge and suction sde of your compressor.
10/31/2009 11:22:29 AM •
Goldstar...
•
Answered
on Oct 31, 2009
•
82 views
Will not run at all
Did you empty the water pan? If it is empty, maybe you didn't put it back in place exactly right, and the cutoff switch is not activated.
7/25/2009 9:46:34 AM •
Goldstar...
•
Answered
on Jul 25, 2009
•
34 views
Dh305y6 won't start
Nothing on display? Remove panels and get to circuit board. Look for loose solder connection on the fuse, etc. Resolder any bad connections. Then turn it on. Let me know.
6/14/2009 12:33:33 PM •
Goldstar...
•
Answered
on Jun 14, 2009
•
156 views