Hitachi EC12 Portable Electric 2hp Air Compressor, Oil Lubricated - Answered Questions & Fixed issues

0helpful
1answer

Hitachi EC12 115v, 14.5 amp air compressor.

if you replaced capacitor exactly like it was remove and no wires switched you have a bad motor.
2/14/2022 11:44:35 PM • Hitachi EC12... • Answered on Feb 14, 2022 • 184 views
0helpful
1answer

Why won't my ec12 air compressor won't start

Check the circuit breaker reset located under the shroud above the dipstick. If the unit hums but won't turn, first drain the air completely and then try it (If it starts, your problem is most likely the check valve located on the tank) 2) Unplug it and carefully use a thin screwdriver to turn the fan blade - if it spins and is not bound then try it again. If it still doesn't start I would look at the start capacitor located under the shroud
3/3/2021 2:21:22 PM • Hitachi EC12... • Answered on Mar 03, 2021 • 510 views
0helpful
1answer

Pls just tell me the oil capacity for the Hitachi EC 12. Thx.

The EC12 holds 8 ounces I recommend synthetic
3/3/2021 2:10:46 PM • Hitachi EC12... • Answered on Mar 03, 2021 • 1,330 views
0helpful
1answer

Compressor not releaving head preasure

The head pressure is released thru the needle unloader valve at the pressure switch. Notice a 1/4 inch plastic tube (or metal) running from the intank check valve to the pressure switch. After pressure switch reaches set pressure a small tang moves up and presses on the needle valve releasing the pressure. Only a small amount of air will be released. If however air continues to escape from the needle valve, then the check valve is bad.
1/21/2019 4:32:10 PM • Hitachi EC12... • Answered on Jan 21, 2019 • 477 views
0helpful
1answer

My ec12 runs for about 5 to 10 seconds then pops the circuit breaker

The EC12 actually draws approximately 15.5 amps when starting, so you are best served to use without extention cord on a 20 amp circuit. One thing that will improve operation, is to use 5w-50 full sinthetic oil. Fill to notch in dipstick. If possible change your overload switch to a 20 amp. It is currently a 15 amp. (cause right there for continual overload). I unplugged my reset button and added a piece of #12 coated wire as a jumper (do this at your own risk), but I've been fine for three years now. #12 wire fits right into the clips that attach to the reset button. Good luck.
12/27/2015 4:14:01 AM • Hitachi EC12... • Answered on Dec 27, 2015 • 544 views
0helpful
2answers

Ec12 hard restart after drop in air pressure

It sounds like the air pressure assembly unit is not reading the pressure drop. some of these units have adjustments under the covers and be reset.
7/9/2015 7:47:32 PM • Hitachi EC12... • Answered on Jul 09, 2015 • 629 views
0helpful
1answer

What oil do I put in my honda cb1000f

Put in the best grade oil for small high RPM engines
6/12/2015 10:08:59 PM • Hitachi EC12... • Answered on Jun 12, 2015 • 179 views
0helpful
1answer
0helpful
2answers

How can i fix my ec12 hitachi electric air compressor

This problem is caused by either the starter capacitor or the in-tank check valve. Ez to check. With no air in tank, start compressor; if motor hums or has difficulty suspect capacitor. If motor starts, partially fill tank and unplug the power. Check for air leaking at the pressure switch or air coming out of the air inlet (remove the air filter). If air leaking, replace check valve. If no air leaking, again let out all the from the tank and connect power. Allow the compressor to fill and shut-off. After the compressor fills, again listen for air leaking from the pressure switch unloader valve. If air continues to leak from unloader, replace the check valve. Good luck
11/22/2016 6:21:06 PM • Hitachi EC12... • Answered on Nov 22, 2016 • 1,322 views
0helpful
1answer

My Hitachi EC12 does not start at all. Plug it in, turned it on and no electrical humming, no start up, nothing. Pressed the reset. Nothing. Is there a fuse that needs replacing? What kinds of things

Does compressor have oil in reservoir? If not, add oil. Also the switch may have gone bad.
6/2/2014 4:40:21 AM • Hitachi EC12... • Answered on Jun 02, 2014 • 1,085 views
0helpful
1answer

EC-12 will turn on, but than sets off overload reset button after 5-10 seconds????Just started doing it???

look for a bad start capacitor.
1/29/2014 8:31:29 AM • Hitachi EC12... • Answered on Jan 29, 2014 • 231 views
0helpful
1answer

Buzzing sound when switch to on

possibly a bad capacitor or motor
12/30/2013 6:21:45 PM • Hitachi EC12... • Answered on Dec 30, 2013 • 62 views
0helpful
1answer

I got a powermate 17 gal it wont shut off not until the breaker trips can't get the air set right on

Find the pressure switch. Remove the cover and loosen the spring loaded nuts on-till the switch opens. Readjust for the pressure you need. Keep it below the amp rating on the motor to keep the breaker from tripping. (RLA or FLA).
12/15/2013 7:03:50 PM • Hitachi EC12... • Answered on Dec 15, 2013 • 59 views
0helpful
1answer

My oil light came on then da car cut off

It sounds like your car ran out of oil and the engine seized
12/9/2013 5:40:24 AM • Hitachi EC12... • Answered on Dec 09, 2013 • 47 views
0helpful
1answer

Hitachi ec119sa compressor tipped over and oil is dripping out of air tank drain vlalve what do I do?

I would not worry. Drain the tank completely, and check the oil in the compressor, top off if necessary. Watch it for the first cycle.
12/2/2013 4:26:32 AM • Hitachi EC12... • Answered on Dec 02, 2013 • 224 views
0helpful
1answer

Porter Cable Pancake compressor builds pressure,

Most P/C compressors shut off at 150psi. If the pressure switch is bad, the pressure will rise until the safety pops. If the safety is not opening, then most likely the cylinder / piston ring is worn to the point that pressure will not increase past safety range (cylinder could be scratched near top ). If cylinder and piston are ok, then air is leaking somewhere (check all joints with soapy water). Good luck
9/18/2013 9:07:36 PM • Hitachi EC12... • Answered on Sep 18, 2013 • 306 views
0helpful
2answers

Hitachi ec12 motor hums after drop in pressue

There should be a pressure switch adjustment under the cover of the switch remove the cover and reset.
7/7/2013 8:27:44 PM • Hitachi EC12... • Answered on Jul 07, 2013 • 1,476 views
0helpful
2answers

When my compressor reaches 120 psi the safety

what is the working pressure bud
5/3/2013 4:43:26 PM • Hitachi EC12... • Answered on May 03, 2013 • 450 views
0helpful
3answers

The air tanks fill with air, but the pressure

The regulator sounds like it is cranked closed. Try slowly operating the adjusting knob in the opposite direction. As the valve moves, you should see the pressure rise on your gauge (it probably does work).
Hope this helps....now go make something!
Best regards, --W/D--
4/13/2013 10:28:49 AM • Hitachi EC12... • Answered on Apr 13, 2013 • 470 views
0helpful
1answer

How do i wire a 110 volt compressor motor with capacitor

With a 110, you do not need a Capacitor
4/12/2013 5:04:04 PM • Hitachi EC12... • Answered on Apr 12, 2013 • 237 views
Not finding what you are looking for?
Hitachi EC12 Portable Electric 2hp Air Compressor, Oil Lubricated Logo

188 questions posted

Ask a Question

Usually answered in minutes!

Top Hitachi Air Tools & Compressors Experts

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Ngoro

Level 3 Expert

3521 Answers

john h

Level 3 Expert

29494 Answers

Are you a Hitachi Air Tool and Compressor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...