Ice Cube Maker - Answered Questions & Fixed issues
Viking vuim150dlss bin t.mister
Do you have a new one? Try comparing the values. There are several types of thermistor. Do you have the type number?
3/16/2014 7:22:12 AM •
Ice Cube Maker
•
Answered
on Mar 16, 2014
•
125 views
Ice not releasing from plate on Viking vuim150drss
HOW OLD IS THE UNIT, AFTER A WHILE THE NICKLE PLATING STARTS TO WEAR OFF THE PLATE WHICH WILL CAUSE THIS PROBLEM AND THEY ARE NOT CHEAP, ALSO CHECK ON THE BOTTOM OF THE MACHINE THERE SHOULD BE A CONTRPL THAT WILL INCREASE THE TIME OF THE RELEASE CYCLE
5/31/2012 2:50:59 PM •
Ice Cube Maker
•
Answered
on May 31, 2012
•
447 views
Evaporator is craked
Hello,
A good very experienced refrigeration guy may be able to repair the evap. coil. This will depend on exactly where the crack is....
The pipe will need to be brazed with a high temperature brazing and then the whole system vacumed down and recharged.
If the crack cannot be fixed then you be be better off to get a new machine...
Heatman101
2/28/2010 2:55:54 AM •
Ice Cube Maker
•
Answered
on Feb 28, 2010
•
67 views
ULINE ice maker is cold but won’t make ice. Need help.
01 - Freezer Temperature is Above 10 Degrees F (-12C)If the freezer temperature is above 10 degrees Fahrenheit (-12C), the ice maker will not produce ice cubes efficiently. The freezer temperature should be set between 0 and 5 degrees Fahrenheit (-18 to -15C) for the ice maker to work properly. If the freezer temperature is too high, ensure that the condenser coils are clear of debris and the condenser fan is working properly. In addition, check to see if frost has accumulated on the evaporator coils. If the evaporator coils are frosted over, part of the defrost system has likely failed.
4/1/2021 4:05:27 PM •
Ice Kitchen...
•
Answered
on Apr 01, 2021
•
183 views
I have ice o matic ice maker its start but after 3 second its turn off.
Assu.ing that the unit has been installed properly and has been working up to know, my 'guess' is a loss of refrigerat. Assuming that the water inlet valve is energized allowing water to enter and trip the high water float. This allows the high gas valve to open, and guessing, a loss of refrigerat is detected and shuts off the operation.
These are very complex, commercial ice makers and need a qualified technician to do a proper troubleshoot of the unit.
6/12/2019 9:50:31 PM •
Ice Kitchen...
•
Answered
on Jun 12, 2019
•
339 views
Line clr60b wont stop making ice
http://www.aramislashes.com/wholesale-mink-eyelashes/wholesale mink eyelashes WHOLESALE MINK EYELASHES MANUFACTURER-ARAMIS LASHES Our wholesale mink eyelashes is more lighter,softer and more Flexible, our 10 year's experience in wholesale mink eyelashes can bring you more hot fashionable mink lashes, you can get top quality from our lashes factory with fast delivery. Most luxury package wholesale mink eyelashes box is available.
http://www.aramislashes.com/wholesale-mink-eyelashes
5/8/2018 3:36:21 AM •
Ice Kitchen...
•
Answered
on May 08, 2018
•
131 views
Not finding what you are looking for?