Not very practical unless you find a donor (identical) vehicle fitted with aircon and even then changing all the parts over would be a considerable amount of work even though a huge saving of cash.

Mitsubishi... | Answered on Feb 11, 2018


Emergency off switch?

Make and model of unit are required for an accurate answer with out this no one can help

Mitsubishi... | Answered on Feb 04, 2018


Have you changed the batteries in the remote? If you have, has anyone spilled anything on the face of the remote?

Mitsubishi... | Answered on Jan 21, 2018


possible but the real reason could be low humidity in the air
no moisture in the air being treated means no condensation forming and no water to drain
of course if the air is not cold from the evaporator , you will need to get it fixed
make sure tat it is not on reverse cycle as that then acts as a heater and there will be no water

Mitsubishi... | Answered on Jan 08, 2018

Tip

Replacing or installing new heat pump


Notes: "ductless" heat pump refers to the mini-split heat pumps
ASSUMPTION: You have an existing forced air system that uses a heat pump for heating and cooling and the heat pump needs to be replaced. You are trying to decide if you should simply replace the existing heat pump with a similar unit, or install a ductless mini-split system and abandon (or remove) the existing ductwork.

Make sure you have addressed any deficiencies with insulation, windows and doors, etc., that have had a significant impact on your homes overall conditioning requirements prior to installing the new system. Doing this will reduce the size requirement of the new heat pump.

This article includes more general suggestions for heat pump installations

General:
    ·Ductless (vs replace existing) will probably cost more to install due to the addition refrigerant piping and electrical that goes to each indoor unit.

    ·Ductless systems have a substantially better efficiency vs your existing unit for several reasons such as: energy losses with the ductwork which can be up to 30%; each room is individually conditioned and has its own remote thermostat so you are not using energy where it's not needed. The thermostats are usually programmable, so you can program the system or just specific indoor units (modules) to provide minimal conditioning during unoccupied periods.

    ·Ductless mini-split systems are the norm in Europe where energy costs are very high.

    ·You'll need a separate indoor modules in each room that you want conditioned, unless rooms have significant openings between them.

    ·One downside to ductless systems that is usually overlooked or not addressed adequately by contractors is the need for fresh air into the spaces, which would normally be supplied with a ducted system via the main air handler. This is important. Your house needs an adequate supply of fresh air to ensure a healthy environment. If you decide to install the ductless system, consider retaining your existing ductwork and use this to provide a minimal amount of fresh air into the home if your house has no other means for fresh air introduction. You should evaluate this carefully. There are guidelines available for determining how much fresh air should be introduced (generally, about 20 cfm for each occupant) and exceeding this amount will place unnecessary load demands on your heat pump, especially during very low or high outside temperatures.

    ·I am not intimately familiar with all residential manufactures so cannot make specific recommendations. However, Mitsubishi was a pioneer in ductless systems and I believe sell far more than any other brand. Their units are virtually everywhere in Europe. In the last 5-10 years, many other HVAC manufacturers have entered the market including Trane, Carrier, Fredrich, York, etc. I have used only their commercial and industrial units, and have found them all to be relatively equal in quality. Watch for compressors that use inverter technology vs reciprocating. Inverter-type compressors are far superior in terms of longevity and energy efficiency.

    ·Watch the energy ratings on the units. Some jurisdictions that offer rebates/tax incentives require a certain minimum SEER rating.

    ·Watch carefully the length of the refrigerant pipe runs. The unit manufacturer will provide a recommended maximum length of pipe run.

    ·Installation is a crucial factor if going ductless mini-split. The contractor MUST be very good, or you'll have problems that could include a much-reduced system life. The refrigerant lines that run from the outdoor unit must be sized properly, plumbed perfectly (the slope of piping is crucial in refrigerant piping) and the unit commissioned properly. Choose the contractor carefully and make sure they have a history of successful installations of systems similar to the one you will install. The installation warranty (and manufacturers warranty) is important.

    ·It's important that the ductless system be sized appropriately. If it's too small or too large you will have problems.

    Air vs ground (geothermal) source heat pumps:
    I am not well-versed in geothermal. In general, the geothermal is superior in terms of efficiency due to the year-around constant "favorable" temperature of the heat source/heat rejection medium. However, it gets complicated when determining the cost/benefit due to several major variables and the relatively high cost of installation (significant costs due to excavation and underground piping). A consultant is probably needed if you get serious about it. Here's a few things to consider:

      ·Soil type is important. Some soils provide better heat transfer than others, and the length of the underground pipe run depends on this variable. Also, the longer the underground pipe runs, the less efficient the system is.

      ·The presence/lack of water has a major influence on length of underground piping. I would imagine that a home located in an area with a very high water table would have a huge benefit over a dry soil location.
      I love the concept of geothermal, but it's an option that needs careful analysis. It isn't used very much, so there are probably good reasons for staying with air source.

on Dec 30, 2017 | Heating & Cooling


How low is this unit sitting .Normally a heat pump mini split must be 6 inches and above from ground because that ice need to drain when it goes into defrost and if it's too low from the ground and don't drain properly ice will started to build up and will eventually burst the coil .

Mitsubishi... | Answered on Dec 16, 2017


try running the unit in the fan only mode. if problem persist this will insure it's an indoor problem. also turn all 3 other systems off and only running problem unit. narrowing down is key

If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79

Mitsubishi... | Answered on Oct 29, 2017


Here is a YouTube video that helps you calculate tonnage of an AC.
The only way to know the running current if it's not on the AC info plate with all the other info is to measure it.

Calculating tonnage of your air conditioner

Mitsubishi... | Answered on Oct 14, 2017

Not finding what you are looking for?
Mitsubishi MSH09TW Air Conditioner Logo

61 questions posted

Ask a Question

Usually answered in minutes!

Top Mitsubishi Heating & Cooling Experts

Marvin
Marvin

Level 3 Expert

85239 Answers

NOEL
NOEL

Level 3 Expert

8549 Answers

Vernon Taylor

Level 3 Expert

7436 Answers

Are you a Mitsubishi Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Mitsubishi Heating & Cooling

  • Mitsubishi Heating & Cooling

Most Popular Question

inside unit outside not turn

  • Heating & Cooling
Loading...