The unit fills with water and then drains

Try to clean the discharge pump filter first (Instructions in the Use/Care manual).

If the drain pump is working, it's most likely related to the pressure switch. Check out this posting:

http://www.fixya.com/support/t9807344-ge_front_load_washer_stops_45_min_35_min
8/26/2021 8:26:06 PM • General Electric... • Answered on Aug 26, 2021 • 2,724 views
0helpful
1answer

GE front load not spinning/draining the water out properly

That could be your trouble the washer has adjustable legs turn legs to adjust level. Also check the belt for worn out.
2/10/2018 3:50:37 PM • General Electric... • Answered on Feb 10, 2018 • 456 views
0helpful
1answer

Have a new ge WCVH6800 front load washer. Power

Hello there and welcome to fixya You may want to try unplugging the machine for a minimum of 2 hours to let the internal cpu to reset itself then plug it back in then press the mode button then try to lock the door and it should be ok after that ok please inform me how this goes there is more we can do for this ok Best regards Michael
8/13/2014 7:46:34 PM • General Electric... • Answered on Aug 13, 2014 • 475 views
0helpful
1answer

Why does myAmana 7300 front load washer door not open?

If the cycle is done, sounds like your door switch could be sticky,. If there is water in it, it will have to pump out the water to a certain level before the door will open, removal of the water would be your issue or the pressure level switch thinks is not drained out, in which would be a pressure switch.
6/18/2014 4:52:15 AM • General Electric... • Answered on Jun 18, 2014 • 47 views
0helpful
1answer

Motor does not turn, but machine does all other functions

check the belt to see if it has snapped or come off, alternatively, if the appliance is between 3-5 years old it might be worth checking the brushes on the motor unfortunately in the UK we do not have this model
4/11/2014 11:43:50 PM • General Electric... • Answered on Apr 11, 2014 • 39 views
0helpful
1answer

General Electric WCVH6800J gasket broken

not to hard to change first you need to get it out there is a spring holding it grab the bottom side of the gasket and you will feel the spring not to hard to doit take a picture or samething to remember how to put it back in make sure the drane hole goes on the bottom.
1/29/2014 2:13:58 AM • General Electric... • Answered on Jan 29, 2014 • 32 views
0helpful
1answer

Spin cycle keeps restarting

Likely to be motor, specifically the brushes. depends on how old the machine is. brushes are replaceable and tend to need replacing from4-5 years with some makes
12/8/2013 11:40:48 PM • General Electric... • Answered on Dec 08, 2013 • 86 views
0helpful
1answer

Replace pump wcvh6800

Bought mine on amazon easy replacement
12/8/2013 4:38:15 PM • General Electric... • Answered on Dec 08, 2013 • 48 views
0helpful
1answer

My pressure switch test said E...how do i fix it

i didnt know they said anything..lol
10/3/2013 2:36:47 PM • General Electric... • Answered on Oct 03, 2013 • 35 views
0helpful
1answer

Lock displaying symbol

Haven't done this exact model but usually it means keypad locked (child lock) should be in the manual how to unlock. Usually hold down a couple of buttons for 5sec.( most of the time a faint lock symbol will be written between the buttons on the button panel.)
9/23/2013 11:11:14 PM • General Electric... • Answered on Sep 23, 2013 • 230 views
0helpful
1answer

Smokes on final spin

door gasket. pain to replace. clean stainless steel drum where it contacts rubber before installing a new one. I used baby oil and very fine steel wool.
5/12/2013 11:47:06 PM • General Electric... • Answered on May 12, 2013 • 233 views
0helpful
1answer

STOPS IN THE MIDDLE OF THE WASH CYCLE WHEN IT NEEDS TO DRAIN TO CONTINUE

E31 is for a slow drain. If the filter and pump are clear of any debris you will need to replace the pump. Here is the part to order.Keep me posted!

All parts come with a 365 day, any part, any reason return policy.

2/3/2013 2:25:32 AM • General Electric... • Answered on Feb 03, 2013 • 174 views
0helpful
2answers

MY GE front load washer stops at 45 min 35 min

I had the same problem. Mine ended up being a cut in the pressure switch hose. Here's what I would do to troubleshoot:

1) Clean the filter down bottom one more time. Run a basket-clean cycle and make sure that the drain pump is working. If so, then move to step 2.

2) Do a diagnostic test. Here's some graphical instructions on how to do it:

Grab the codes off the t02 error codes test. There is a reference manual for the codes in a plastic envelope behind the bottom access panel on the front of the washer (panel below the door) -- remove the 3 screws then pull out from bottom. Lookup the codes and see what they mean.

Mine was E22 -- which indicates problem with pressure switch.

chris_in_ma.jpg
chris_in_ma_0.jpgchris_in_ma_1.jpg
3) Do the t06 basket test. If it fails, then open up the top of the washer to check the pressure switch and hose:
chris_in_ma_2.jpg
chris_in_ma_3.jpg
Twist the pressure switch 90 degrees clockwise toward the spring to release it. Undo the hose clamps and blow down the hose. Blow into the pressure switch to make sure a contact isn't stuck. I took the bottom panel off the washer and disconnected the other end of the pressure tube from the bottom of the tub. Once disassembled, I blocked the end with my finger to see if the hose was punctured -- sure enough it was. I taped it and reassembled. If after repairing and blowing out, if you still have problems, replace the pressure switch ($60 on Amazon).
12/13/2013 1:10:54 AM • General Electric... • Answered on Dec 13, 2013 • 6,524 views
0helpful
2answers

My GE washer model #WCVH6800J1MS occasionally leaks from the bottom. It sits on a pedestal so I can't see exactly where the water is coming from.

Remove the 3 screws from the lower kick-plate and run a load to see if you can find where the leak is coming from.
1/10/2013 11:14:50 AM • General Electric... • Answered on Jan 10, 2013 • 525 views
0helpful
1answer

Starts and shuts off

Clean the drain filter.
11/25/2012 6:40:37 AM • General Electric... • Answered on Nov 25, 2012 • 32 views
0helpful
1answer

GE front loader water wont stop running

If the water runs continuously on the unit then the "water inlet valve" is bad and needs to be replaced. Here is the part you need.
10/23/2012 3:15:38 AM • General Electric... • Answered on Oct 23, 2012 • 65 views
0helpful
2answers

GE Model WCVH6800J Error Code 04.

TROUBLESHOOTING CHART
Codes Description Action
------------------------------------------------------------------
22,23 Fill problems
• Ensure manual water valves are fully open.
• Check if water strainers on solenoid valve assembly are clogged.
• Check for obstructions inside inlet water hoses.
• Ensure solenoid valves do not leak when the valves are de-energized and the washer is powered down. • Measure coil resistance for both valves; if outside range (1000-1250 ohms at room temp.), replace solenoid valve
assembly.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM, OR FOR ERROR CODE 23:
• Replace solenoid valve assembly.
------------------------------------------------------------------
30, 31 Drain problems
• Ensure pump strainer is clean and free of debris.
• Check for obstruction inside the drain hose.
• Check pump impeller blades and bearing; if evidence of blade damage or seized bearings are present, replace the pump.
• Check electrical connections at the pump motor and harness.
• Measure pump motor resistance; if outside range (9-14 ohms at room temp.), replace the pump.
------------------------------------------------------------------
38,39 Dispenser problems
• Check for obstruction in dispenser mechanism and linkages.
• Check electrical connections at dispenser motor feedback switch and in the harness.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
• Replace dispenser motor assembly.
------------------------------------------------------------------
42,45, 49 Motor Drive operation above design limits
• Ensure all 4 shipping bolts have been properly removed.
• Remove all foreign objects that may be lodged between inner and outer basket.
• Look for signs of seized bearing(s) on basket and drum motor, replace components as necessary.
• Inspect condition and mounting of door gasket, replace and re-mount as necessary.
• Ensure inner basket (drum) can rotate freely.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
• Replace motor drive or drum motor.
------------------------------------------------------------------
43,4A, 4B,4C, Motor Drive internal problems
4E,4F, 50,52,
53,54

• Measure AC outlet voltage, ensure correct range (102V to 132V AC).
• Check electrical connections at the drum motor, motor drive.
• Check harness integrity between main control and motor drive.
• Unplug the unit, wait 30 seconds, restart the unit.
• If the fault persists and re-appears -replace the motor drive.
problems
------------------------------------------------------------------
57,58,71 Main Control internal problems
• Unplug the unit, wait 30 seconds, re-start the unit.
• If the fault persists and re-appears -replace the main control.
------------------------------------------------------------------
60,61,63,64, DOOR LOCK assembly problems
• Check integrity of wiring and connections between main control and DOOR LOCK mechanism.
• Investigate DOOR-LOCK mechanism, check door microswitch operation, lock and unlock solenoid continuity, contact integrity;
replace DOOR LOCK mechanism if necessary.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
• Replace the main control.
------------------------------------------------------------------
65 Water Level Sensor problems
• Check integrity of wiring and connections between main control and Water Level Sensor.
• Check integrity of Water Level Sensor, replace if necessary.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
• Replace the main control.
------------------------------------------------------------------
66,67 Water Temperature Sensor problems
• Check integrity of wiring and connections between main control and HeaterfThermistor Assembly.
• Using ohmmeter, measure Thermistor resistance; if outside expected range, replace HeaterfThermistor Assembly.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
• Replace the main control.
------------------------------------------------------------------
70 "Stuck" key
• Press each key. There should be mechanical "click" feedback with every press.
• Enter Service mode, use 104 test to check key operation. Press every key. Every keypress should generate audible
"beep." Press "Power" key last to avoid premature exit from t04 test.
• Separate control and control housing from the front panel; clean and remove all foreign matter and debris from keys,
front panel and control housing, re-assemble. Ensure all keys can be operated freely without "sticking."
IF ABOVE STEP DOES NOT CLEAR THE PROBLEM:
• Replace the main control.
------------------------------------------------------------------
62 System Contact Failure
• Check integrity of wiring and connections, look for insulation breakdown and short circuit conditions on the harness, replace
harness if necessary.
• Check integrity and electrical connections of all loads (heater, pump, pressure switch, door lock, solenoid valves,
dispenser motor), replace respective components if necessary.
IF ABOVE STEPS DO NOT CLEAR THE PROBLEM:
• Replace the main control.
10/7/2012 12:58:55 AM • General Electric... • Answered on Oct 07, 2012 • 1,980 views
0helpful
1answer

Unlock

see this causes and fix it. God bless youFirst to unlock depending on model. There will be a pull tab either under the lower kick panel, behind the filter cover, or under the top panel. Pull this tab to unlock the door. Now you can remove the clothes and water. Refer to the owners manual for the location of your emergency door pull tab. Door Switch You will need to remove the door switch to check it. You will perform an ohm reading on the bottom terminals. The reading varies from manufacturers most Frigidaires is around 1500 ohms others like the whirlpool duet is checked at the main control board with the door closed should be around zero ohms. You will need to refer to the tech sheet or service manual for the proper reading. Main Control Module / CCU The main control unit is the circuit board located behind the console. If the door switch tests good the main control is usually the problem. Check all connections for a goood tight fit. You will need to refer to the tech sheet or service manual to check this further. The main control is easy to replace.
10/2/2012 1:13:35 PM • General Electric... • Answered on Oct 02, 2012 • 52 views
0helpful
1answer

T02 error code 30

E30 means that the control isn't getting an electrical signal from the water pump. A clogged pump, bad pump, loose connection or a bad control board can cause this error code. The first thing you will want to do is check for a loose connection. Then make sure the pump isn't clogged. Check the pump motor with an ohmmeter and if it is open replace it. At this point the only way to tell if the control or the water pump is the problem is to run the water pump test on this page Test for voltage at the pump during the test. If the pump is getting power but will not run, replace the water pump and if the pump isn't getting power, replace the control.
9/8/2012 10:04:22 PM • General Electric... • Answered on Sep 08, 2012 • 134 views
0helpful
1answer

GE WCVH6800J1MR wont spin or drain

sound like the water pump is shot
2/19/2012 11:33:28 PM • General Electric... • Answered on Feb 19, 2012 • 411 views
Not finding what you are looking for?
General Electric WCVH6800J Front Load Washer Logo

180 questions posted

Ask a Question

Usually answered in minutes!

Top General Washing Machines Experts

Oloyede Monsuru

Level 3 Expert

1468 Answers

sheakhly

Level 1 Expert

33 Answers

Dan Webster
Dan Webster

Level 3 Expert

8221 Answers

Are you a General Washing Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides