The light on my chest
Both light flickering probably indicates a problem with the plug or the cord. If it was just the inside light I would suspect the door switch, but both light would indicates an open short in the wires or plug.
Check the plug connection at the wall and see if it is loose. While unplugged check the cord for any nicks or cuts. Plug something else into the same wall receptacle , like a light and see if the power to the receptacle is ok.
If none of the above work then it is time for a qualified repair person.
J
2/20/2018 12:39:02 AM •
Woods Chest...
•
5,354 views • 0 helpful votes
Freezer problelm
I would try replacing that overload and relay in the compressor. Your compressor may be shorted out. If it is, replacing relay and overload won't help.
Light bulb replacement
Try a APPLIANCE PARTS/REPAIR shop..... If they can not get it for you, it can not be gotten....
IF THERE IS A HOLE INNSIDE THE FREEZER
The hole is for cleaning and draining. It has little effect on the temp.. Do you have to put bottles inside? To start with, liquids expand as they freeze and get hot. Anything below freezing is going to give you a problem. The colder, the sooner it will break the bottles.
MI have a Frigidaire chest
No it is not normal. But it is an easy fix! Clean the condenser grill and make sure that the compressor fan is working.
When the condenser grill is dirty it can't get rid of the heat from the compressor, so it transfers the heat to the cabinet. Also make sure that you have air space behind your unit and it is not crammed against the wall.
Note: If this is in your garage or in a closet, suggest you put it up on 4x4 blocks so that it can get plenty of air flow around it and you will even save some electricity since it won't have to work so hard.
Woods 221 chest freezer light
The problem is with lamp holder. You should remove the covel and reach for the lamp and remove it. First remove the power cable of freezer. Now try to bend the center back contact of the lamp holder which is actualy not making good contact with the lamps back contact point. You can use also a wire brush, or a glass paer to clean the contacts of bothe the holder and lamp. Also it may be nessesary to use a new lamp since sometime their contacts are melt a litle bit and they loose contact. In the worst case you may need a new lamp holder.
We have here a link with your model
parts diagram, if the model differs then you make a research with correct model so you can have correct leyout.
The outside front of the
It's normal to touch it hot on the outside front.
Because it has heater to keep moisture out in the body metal of the freezer.
Those moisture if not heated to dry, can cause rust build up.
Rust build up can destroy the metal body of the freezer.
Thanks for asking.
Freezer runs but is not cold enough. Water runs
Sorry to read about your problem, I hope this helps you out.
Make sure you coils are clean with, no dust. use a vacuum and blower to remove dust and dirt.
if all coils are clean and you still have a issue, you may be low on freon.
I tried to help you. Please help me and Rate/Vote on my response. We take the time to answer your question's. take the time to rate us.Thanks and good luck
4 Thumbs - Very Helpful
3 Thumbs - Helpful
I have a elderly lady
It sounds like a compressor issue either the unit has lost pressure on the free on side, bad compressor, low free on or gases, or cooling fan for the compressor to keep it cool stoped working. thanks
I bought freezer a month ago its like new only
This is what is called the syndrome of long time relaxing. If the freezer stayed for more than a month not used there is a very big chance the Freon stayed in with pressure and some humidity at some points so if at any point of the piping system there were a weak point then you probably had a Freon leak.
So you may have a freezer that looks like new but the cooling is in bad situation.
You can confirm this if you touch the condenser and after 1 hour you had switch it on, then the temperature of condenser should be about 110-120 F. If it is less than 100 F then you had a Freon leak.
In this case deal with Freon is not a DYI job since you need special tools and also you need to have a special licence for this.
We have consider that the compressor if working fine.