Bryant 3.5 Ton R22 12 Seer Condenser Only/ Unit has an R22 Charge - Page 7 Questions & Answers
My coil is all rusted
Highly unlikely, I would just get a few prices on replacing and get it done. Hard to prove a factory defect & most warranties are on moving parts & electrical.
We want to add a
The return lines normally return to the boiler on the side. the supplies are on top (header)
I am looking for a
That's what the internet is for. Ask a question, and I will try to answer.
I HAVE A 20+
Turn the gas valve to pilot. Push knob down & hold. While holding, light pilot & keep knob held down for one minute. Let go of knob & see if pilot stays lit. then turn knob to on position. Boiler should then turn on.
My furnance will not light.
The ignitor is hot surface I'm assuming. If it is, it will have a molex plug on the 2 lead wires. Unplug & Ohm it out with an Ohm meter. It should be anywhere between 50 & 100 ohms. If the resistance is any higher, replace it.
The Blower Motor on the
Pull the capacitor & have it checked for the correct microfarads rating with an electrical meter. If the reading doesn't match the rating stamped on the side of the capacitor, replace the capacitor. If the capacitor reads fine, then make sure you have proper voltage to the motor... and if you do, then replace the motor.
WE have a central unit.
Sounds to me like your indoor evaporator coil needs to be cleaned...check your air filter first.
I lost power yesterday
If the outdoor fan is running with no cooling it is possible that the power issues could have taken out the compressor (power surge).
Ac squirrel cage fan motor noise
Could be bearings going out, or a squirrel cage rubbing the blower housing, a squirrel cage blade that came loose, or a capacitor.
Buzzing Refrigerant Lines
Have someone check your pressures & temperatures in your refrigeration system. Also check the compressor amps with an analog meter to see if the amps fluctuating. There might be something wrong with the compressor.
I have a Bryant 310AAV furnace that is not blowing
I have a 234c-4pw boiler that has been worked on by a plumbing company they have replaced zone valves and replaced the 3 speed pump to a single speed pump now it wont even push the air out of the system
Manual for model no. 234c
I have a bryant boiler in my home and been having a plumbing co work on it since spring and they replaced the 3 speed pump with a single speed now cant get it to push air out of system