20 Most Recent GE Profile 25.6 Cu. Ft. Side-by-Side Refrigerator with Thru-the-Door Ice and Water - Stainless-Steel - Page 8 Questions & Answers

0helpful
1answer

GE DSS25KSRESS SIde by Side

The frost free function is not working consistently causing the coils to coat with ice. The usual cause is a failure of the thermostat for the coils or the heating elements or the timer which is often mounted on the front rail at the toe kick area. Unless you are handy at electrical and have access to appliance parts this is probably not DIY... cost is often $250 which is far less than new refrigerator. Also check if your warranty might be valid or any maintenance contract.
4/2/2011 4:50:32 AM • GE Profile 25.6... • Answered on Apr 02, 2011
0helpful
1answer

Our freezer is working fine but the air flow to

Hi,

Check out these tips...they can help you figure out what is going wrong withyour refrigerator and why it is not cooling

Refrigeratornot Cooling or Fridge not Cooling

How to Defrost Refrigerator DefrostTimer Problem

WaterRunning in refrigerator from Freezer

Refrigeratoror Freezer not Cooling or Getting Cold
heatman101
4/2/2011 3:38:49 AM • GE Profile 25.6... • Answered on Apr 02, 2011
0helpful
2answers

I have a GE Profile Performance side by side about

Hi,

Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong. If you are hearing a clicking or buzzing thencheck out the last two tips.

If your refrigerator is running but warm, then...

Check out these tips that I wrote about that... it is a great place to starttrouble shooting your unit...and something that you can do rather then callinga repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay
Refrigerator or Freezer not Cooling or Getting Cold

heatman101
4/1/2011 12:15:50 PM • GE Profile 25.6... • Answered on Apr 01, 2011
0helpful
1answer

Temperature rising in freezer and fridge motor

The temperature in the freezer will rise if there is no air circulation. Air circulation stops when the evaporator freezes solid. When this happens the thermostat cn not respond and the fridge keeps running.
Defrost the freezer and see if things return to normal. If they do then you have an auto defrost problem.
A technician can help you with this problem
4/1/2011 11:22:09 AM • GE Profile 25.6... • Answered on Apr 01, 2011
0helpful
1answer

Our GE Arctica was making a buzzing noise. It

Hi,

Here is a tip that I wrote about refrigerators and the fan noisethat they develop sometimes...

RefrigeratorFan Noise
heatman101
4/1/2011 1:45:54 AM • GE Profile 25.6... • Answered on Apr 01, 2011
0helpful
1answer

My GE side by side refrigerator model PSC25MSWA

HI no these techs are wrong, you need to change the motherboard, gas/freon leaks are less than 2% of failures on GE refrigerators. Change the board and you will be fine.



Sean
3/31/2011 9:00:53 PM • GE Profile 25.6... • Answered on Mar 31, 2011
0helpful
1answer

Refrigerator is running at 50 degrees and freezer

Hi,

Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling

Refrigerator not Cooling or Fridge not Cooling

How to Defrost Refrigerator
Defrost Timer Problem

Water Running in refrigerator from Freezer

Refrigerator or Freezer not Cooling or Getting Cold

heatman101

3/27/2011 10:19:04 PM • GE Profile 25.6... • Answered on Mar 27, 2011
0helpful
1answer

Hi need a manual for GE Profile side x side

Go to GEAppliances.com and use your model number to search for free downloadable manual.
3/26/2011 4:48:58 AM • GE Profile 25.6... • Answered on Mar 26, 2011
0helpful
1answer

G.e refrig gsh25jre makes a clicking noise refrig

The clicking noise means the computer board is bad. It will have to be replaced.
3/21/2011 9:43:26 PM • GE Profile 25.6... • Answered on Mar 21, 2011
0helpful
1answer

Air from freezer and refrigerator is not cold.

Hi,

Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong. If you are hearing a clicking or buzzing thencheck out the last two tips.

If your refrigerator is running but warm, then...

Check out these tips that I wrote about that... it is a great place to starttrouble shooting your unit...and something that you can do rather then callinga repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay
Refrigerator or Freezer not Cooling or Getting Cold

heatman101
3/19/2011 3:10:33 AM • GE Profile 25.6... • Answered on Mar 19, 2011
0helpful
1answer

Ice build up on the floor of the freezer. A water

Hi,

Check out these tips...they can help you figure out what is going wrong withyour refrigerator

Refrigeratornot Cooling or Fridge not Cooling

How to Defrost Refrigerator DefrostTimer Problem

WaterRunning in refrigerator from Freezer

Refrigeratoror Freezer not Cooling or Getting Cold
heatman101
';';][][
3/19/2011 2:54:56 AM • GE Profile 25.6... • Answered on Mar 19, 2011
0helpful
1answer

GE model # GSS25JFMCWW has water to the

could be a number of thing,s The device that sends water to the ice/mak is different than the door water the ice maker has it,s own brain (circuit) water in/out some built into the frig itself . The ice /mah send siginal to water valve to send water.. to ice maker sorry icall appl man sorry
3/18/2011 2:27:46 PM • GE Profile 25.6... • Answered on Mar 18, 2011
0helpful
1answer

The freezer side stays on 10 below. every 2or 3

HI, this is pretty normal,the frig is going into defrost cycle so you dont have ice build up in your frost free frig.
3/12/2011 1:56:15 PM • GE Profile 25.6... • Answered on Mar 12, 2011
0helpful
1answer

We have just replaced our water filter and now the

Remove the filter and run the water to see if it improves.
If not,the water line and or the water valve need attention.
3/10/2011 12:52:10 PM • GE Profile 25.6... • Answered on Mar 10, 2011
0helpful
1answer

AIR DAMPNER STAYS CLOSED

Hello,

Very common issue, the main control on the back fails to send power to the damper, replace the board to fix this issue,

http://www.appliancerepairlesson.com/
3/8/2011 5:34:53 AM • GE Profile 25.6... • Answered on Mar 08, 2011
0helpful
1answer

Ice build-up in bottom of freezer due to stopped

Very common, remove the back panel in the freezer pour hot water down the drain hole. The defrost drain line is blocked, I know this unit very well can help you more if you need, let me know,

http://www.appliancerepairlesson.com/
3/8/2011 5:25:11 AM • GE Profile 25.6... • Answered on Mar 08, 2011
0helpful
1answer

MY WATER DISPENSER IS NOT WORKING. SEARS

Check any kinks or tints in water tube, correct it. And also check water pressure in water supply.
Thanks.
3/5/2011 10:34:12 PM • GE Profile 25.6... • Answered on Mar 05, 2011
0helpful
1answer

Refrigerator every once in a while makes popping

If you use your automatic ice maker, every now and then it has to clear out the ice from the ice tray and put it in the ice storage bin. If it sounds like ice falling then this could be the problem, if it sounds like plastic gears grinding there could be somethnig wrong with the ice removal system.
3/1/2011 9:52:57 PM • GE Profile 25.6... • Answered on Mar 01, 2011
0helpful
1answer

Refrigerator isn't cold enough, but the freezer is

This problem is related to defrost.The defrost cycle is not running as it should be. The other possibility can be ice blockage in the ventilations.The defrost is not working,.The evaporator coil in the inner section of freezer is got blocked by ice .
Try manual defrost reset procedure: ----
First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced.
-------------------------------------------------
Check the damper if there is too much water collected in the damper then press the damper and remove the water collected in it. The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the refrigerator section and the refrigerator section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located. Now this problem which you mentioned. In this problem the freezer works but no cooling in fridge, this happens if the thermostat is not functioning or the heater is not heating. Then the ice starts getting collected on the evaporator coil. The evaporator coil is at the internal section of freezer. If too much ice gets
collected then this ice blocks the fan in the freezer section from functioning and this blocks the damper section with ice getting collected there. This all procedure is controlled by the main defrost board of the unit. Now if the damper is not got blocked with too much water or if the ice is not got collected on the damper area then check the evaporator coils. If there is too much ice got collected on the coils, then takes a hair dryer and melt the collected ice. Then see if the problem returns again. But if there is little bit ice collected on the coils and fan is running properly then it's not a problem. In that case main defrost board is faulty and it has to be replaced. The main defrost board is working but its not controlling the functions as required so the freezer works but fridge section not getting cold..
---------
You can get required parts from sears part direct online site or from repairclinic.com site.
--------
This will help. Thanks. Helpmech.
3/1/2011 7:45:21 PM • GE Profile 25.6... • Answered on Mar 01, 2011
Not finding what you are looking for?
GE Profile 25.6 Cu. Ft. Side-by-Side Refrigerator with Thru-the-Door Ice and Water - Stainless-Steel Logo

350 questions posted

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Johnny 1000

Level 2 Expert

94 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

GE Refrigerators

  • GE Refrigerators

Most Popular Question

ge profile 2004 open door temp controls

  • Refrigerators