GE DSS25KSRESS SIde by Side
The frost free function is not working consistently causing the coils to coat with ice. The usual cause is a failure of the thermostat for the coils or the heating elements or the timer which is often mounted on the front rail at the toe kick area. Unless you are handy at electrical and have access to appliance parts this is probably not DIY... cost is often $250 which is far less than new refrigerator. Also check if your warranty might be valid or any maintenance contract.
Temperature rising in freezer and fridge motor
The temperature in the freezer will rise if there is no air circulation. Air circulation stops when the evaporator freezes solid. When this happens the thermostat cn not respond and the fridge keeps running.
Defrost the freezer and see if things return to normal. If they do then you have an auto defrost problem.
A technician can help you with this problem
GE model # GSS25JFMCWW has water to the
could be a number of thing,s The device that sends water to the ice/mak is different than the door water the ice maker has it,s own brain (circuit) water in/out some built into the frig itself . The ice /mah send siginal to water valve to send water.. to ice maker sorry icall appl man sorry
Refrigerator every once in a while makes popping
If you use your automatic ice maker, every now and then it has to clear out the ice from the ice tray and put it in the ice storage bin. If it sounds like ice falling then this could be the problem, if it sounds like plastic gears grinding there could be somethnig wrong with the ice removal system.
Refrigerator isn't cold enough, but the freezer is
This problem is related to defrost.The defrost cycle is not running as it should be. The other possibility can be ice blockage in the ventilations.The defrost is not working,.The evaporator coil in the inner section of freezer is got blocked by ice .
Try manual defrost reset procedure: ----
First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced.
-------------------------------------------------
Check the damper if there is too much water collected in the damper then press the damper and remove the water collected in it. The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the refrigerator section and the refrigerator section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located. Now this problem which you mentioned. In this problem the freezer works but no cooling in fridge, this happens if the thermostat is not functioning or the heater is not heating. Then the ice starts getting collected on the evaporator coil. The evaporator coil is at the internal section of freezer. If too much ice gets
collected then this ice blocks the fan in the freezer section from functioning and this blocks the damper section with ice getting collected there. This all procedure is controlled by the main defrost board of the unit. Now if the damper is not got blocked with too much water or if the ice is not got collected on the damper area then check the evaporator coils. If there is too much ice got collected on the coils, then takes a hair dryer and melt the collected ice. Then see if the problem returns again. But if there is little bit ice collected on the coils and fan is running properly then it's not a problem. In that case main defrost board is faulty and it has to be replaced. The main defrost board is working but its not controlling the functions as required so the freezer works but fridge section not getting cold..
---------
You can get required parts from sears part direct online site or from repairclinic.com site.
--------
This will help. Thanks. Helpmech.