20 Most Recent GE 25.0 Cu. Ft. Side-by-Side Refrigerator with Thru-the-Door Ice and Water - Black-on-Black - Page 3 Questions & Answers

0helpful
1answer

Icing up where ice cubes drop from door

door to ice shute not closing tight replace with door kit . for your model the newer model uses a better seal and a stronger spring . .. mm
8/11/2010 9:13:11 AM • GE 25.0 Cu. Ft.... • Answered on Aug 11, 2010
0helpful
1answer

Have a GE hot point HSS25GFTABB, removed doors to

Inspect the line crefully at the bottom of the door where it connects to the cabinet supply. The line may have been damaged when and if the doors were removed.
HOPEFULLY it is a small nick in the tubing casuing the water leak, and not the line inside the freezer door as the water line is foamed into the door and the entire door would have to be replaced to resolve an internal leak.
The coupler at the door connection is a push-lock syle coupler and to seperate the line you need to press the white collar into the blue barrel connector to relese the tension.
Good luck!
7/29/2010 4:31:52 PM • GE 25.0 Cu. Ft.... • Answered on Jul 29, 2010
0helpful
1answer

The water dispenser stops flowing

if using a het gun corrected the problem before / the ck the freezer tempt it may be to low . adjust to 0 to 5 deg in freezer . if you still have problem we sometimes run the tube through anothe larger tube.. this helps freezing . mm
7/29/2010 9:02:30 AM • GE 25.0 Cu. Ft.... • Answered on Jul 29, 2010
0helpful
1answer

DEFROST PROBLEM

you said a mouth full . any of the 3 would cause freeze up.. so make sure the inside fan (evap fan is working ) . if unit is newer one the control in side fresh food may be bad and the sensor in the freezer. if it does not sense tempt properly the compressor run time is too long causing freeze up . now some times new components fail so ck them . . clean the bottom coils . and make sure the bottom fan is cooling the coils .. mm
7/29/2010 8:37:36 AM • GE 25.0 Cu. Ft.... • Answered on Jul 29, 2010
0helpful
1answer

GE ice maker auger installation

Try this link it should be pretty close http://appliancehelponline.com/sxsaugermotor.html
7/26/2010 6:28:04 PM • GE 25.0 Cu. Ft.... • Answered on Jul 26, 2010
0helpful
1answer

I don't think its defrosting,

you have a defrost probelm could be the defrost thermostat defrsot timer or defrost heater usually its the thermostat test the t-stat for continuity on both ends if there is none then replace the t-stat you can find the part at marcone appliance parts hope this helps
7/26/2010 3:48:08 AM • GE 25.0 Cu. Ft.... • Answered on Jul 26, 2010
0helpful
1answer

Water button lights up green but no water comes

Hi. Check to be sure that the fridge has the water supply connection made. It is on the back of the fridge. Often, a 1/4 inch plastic or copper line runs from the back of the fridge to under the sink. There would then be a small faucet at that connection which would have to be turned on. j.
7/24/2010 10:12:49 AM • GE 25.0 Cu. Ft.... • Answered on Jul 24, 2010
0helpful
1answer

Water leak in front of frig.

use a syringe with clorine bleach to blow out the drain hole,(a meat/gravy syringe works fine...)
7/21/2010 9:17:49 AM • GE 25.0 Cu. Ft.... • Answered on Jul 21, 2010
0helpful
1answer

Not getting cool

Hello,

UNPLUG THE UNIT.
You will need to remove that lower rear wall of the freezer.

Leave the doors opened until all that frost has melted out of the coils behind that wall. You will need some towels as some will get on the floor.

Once it is all melted out at the bottom of the coils there is a part attached with a pink and blue wire. You can test this part with a meter. Put the meter in the ohms setting. If you get a reading the part is good. If you get no reading the part is bad. This is the defrost heater.
Be sure to check it as there can be another part bad. If you find that this part is good let us know.

Now you can operate the unit with the wall in place for about 2 weeks after you get the frost melted out. This should give you time to get the new one installed. If you decide to use a hair dryer be aware that the plastic melts at a very low temperature.

Thanks
7/19/2010 7:36:50 PM • GE 25.0 Cu. Ft.... • Answered on Jul 19, 2010
0helpful
1answer

Water is not working

You have two points where you can check the dispenser water. At the rear where the water supply comes in is the water inlet valve. If you disconnect the dispenser water line and then see if the water comes out when you try the dispenser. You should hear the valve work when you try the dispenser. If you don’t hear it there is a dispenser actuator switch problem. If you do hear it but water doesn’t work here there is a valve or water supply problem.
If it's normal, disconnect it at the bottom of the freezer door and try again.If it's normal here it may be frozen in the door. If this is the case open the door till it thaws. A blanket over the opening will prevent thawing of all the food.
7/12/2010 12:37:20 AM • GE 25.0 Cu. Ft.... • Answered on Jul 12, 2010
0helpful
1answer

My ice maker pushes out ice into container but the

Sounds like the gear that turns the auger has broken or stripped , the beeeping is to let you know that something has falled. Slow water can be one of several this, the strainer in the water valve is partly stopped up, you could have a kink in the supply line, the water cut off valve could be clogged or the water valve itself maybe going bad.
6/23/2010 5:11:18 PM • GE 25.0 Cu. Ft.... • Answered on Jun 23, 2010
0helpful
1answer

How to tighten loose door handle

should be a small access cover on the handle top and bottom pop them open with a flat small screw driver screws should be underneath
6/9/2010 11:40:57 AM • GE 25.0 Cu. Ft.... • Answered on Jun 09, 2010
0helpful
1answer

Not making ice cubes

Hi,
Here are some basic tips for ice maker troubleshooting2_bing.gif...

Ice Maker Problems and Ice Maker Troubleshooting
http://www.fixya.com/support/r3876071-ice_maker_problems_ice_maker

heatman101
6/9/2010 3:27:12 AM • GE 25.0 Cu. Ft.... • Answered on Jun 09, 2010
0helpful
1answer

NOT DEFROSTING

It can be a problem with deforst heator / evap sensor change the evaperator sensor. evap sensor can cause missed defrosts or no defrosts. It should fix the problem, You can also check this web site gelow its the complet repair guide: http://www.appliance-repair-it.com/GE-refrigerator-repair.html
6/6/2010 3:52:33 AM • GE 25.0 Cu. Ft.... • Answered on Jun 06, 2010
0helpful
2answers

Ice door will not close tight

You will need to re place the soliniod that closes door flap
5/21/2010 10:51:07 AM • GE 25.0 Cu. Ft.... • Answered on May 21, 2010
0helpful
1answer

Where is the drain in the freezer? Can I access it?

Hi,

It is near the bottom of the freezer, if you remove the lower basket/shelf you will see a 'step up' and a back panel with slots above the step. The drain opening is just below the slots in the back panel. This link may help if you are going to clean it out. Let me know if it helps. Thanks

http://www.fixya.com/support/r4686046-water_leak_from_freezer_ice_freezer
5/3/2010 9:47:32 PM • GE 25.0 Cu. Ft.... • Answered on May 03, 2010
0helpful
1answer

Not very cold

Hi,
As the weather is getting warmer for many people their freezer2_bing.gif and/or refrigerator do not work right because of a dirty condenser coil...

Check out this tip that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

http://www.fixya.com/support/r4024657-refrigerator_condenser_coil_cleaning


http://www.fixya.com/support/r4588788-refrigerator_or_freezer_not_cooling_or

http://www.fixya.com/support/r3885294-refrigerator_troubleshooting

http://www.fixya.com/support/r4023749-refrigerator_compressor_start_capacitor

heatman101
4/30/2010 12:17:13 AM • GE 25.0 Cu. Ft.... • Answered on Apr 30, 2010
0helpful
1answer

Ice maker not making ice.

TRY DISCONNECTING THE ICE MAKER FROM INSIDE AND RUN HOT WATER OVER IT UN TIL IT IS COMPLETELY THAWED, THEN RECONNECT IT AND SEE IF IT WILL MAKE ICE NOW. SOMETIMES ICE MAKERS CAN BECOMED BLOCKED BY ICE.
4/13/2010 8:21:47 PM • GE 25.0 Cu. Ft.... • Answered on Apr 13, 2010
0helpful
2answers

Water dispenser is not working.

replace the filter.
if tht dosent work replace the water valve....
4/11/2010 2:29:25 PM • GE 25.0 Cu. Ft.... • Answered on Apr 11, 2010
0helpful
1answer

Door Ice dispencer Problem

First , remove the top freezer door hinge cover ( only held by 1 screw ) . Disconnect the plug there , to remove power to the door . Use a butter knife or flat head screw driver , and pry outward from the BOTTOM of the dispensor control plate . Disconnect the 3 plugs there and set aside . Remove the 3 or 4 screws holding the arm and cover in place , and slide out . Your problem , is probably a rusted coil and plunger , in the top right corner with 2 black wires going to it . The part # is WR62X10055 . Solenoid coil and plunger is the correct term for it . Cleaning will not work for long , only replacing will correct for a long period of time .
4/10/2010 9:54:51 PM • GE 25.0 Cu. Ft.... • Answered on Apr 10, 2010
Not finding what you are looking for?
GE 25.0 Cu. Ft. Side-by-Side Refrigerator with Thru-the-Door Ice and Water - Black-on-Black Logo

94 questions posted

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Johnny 1000

Level 2 Expert

94 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

GE Refrigerators

  • GE Refrigerators

Most Popular Question

freezer refrigerator maintain good

  • Refrigerators