check for clog or test for failed element

Krups Coffee... | Answered on Nov 05, 2018 | 141 views


I'm not familiar with the model but I do know that you need to complete each and every step fully before the light goes out on the models I've worked on. Run through it again slowly before you worry yourself about a repair.

Krups Coffee... | Answered on Oct 24, 2018 | 151 views


????? ???? ese ??????????

Krups Coffee... | Answered on Oct 20, 2018 | 163 views


The heat sensor on the boiler is not detecting any temperature change. It could be a wire or terminal off. The sensor is right at the front of the boiler. If the sensor is faulty it means a new boiler because it's stuck on in the factory.

Krups Coffee... | Answered on Oct 02, 2018 | 248 views


Error 9 is only related to the NTC on the front of the thermobloc. That's the wires, terminals or the resistor on the NTC that changes value with heat.

Krups Coffee... | Answered on Sep 25, 2018 | 183 views


There are three things it could be, the motor that drives the brewing unit, the brewing unit itself or the pressure relief valve. You need to operate while looking inside with a torch to see what is happening. This is done with the back, the top and the beans side side cover removed for visibility.

Krups Coffee... | Answered on Sep 08, 2018 | 387 views


Krups Optisteam Food Steamer with manual was for sale on ebay with a manual, but is no longer available.

https://www.ebay.com.sg/itm/Krups-Food-Steamer-Optisteam-649-With-Manuals/123088622624

Krups Coffee... | Answered on Aug 11, 2018 | 126 views


Error code 01 accompanied by that noise points at the distributor being faulty. The distributor is the electronic tap that directs water to the ram to compress the grounds in the boiler and then redirects it to the brewing chamber to make the coffee, then to steam, then to rinse. It's the sort of item you just replace because it's quite a large job to change it anyway, not the sort of repair you want to be doing over and over trying not to spend money on the part.

Krups Coffee... | Answered on Aug 02, 2018 | 619 views


OA means that the sensor is not detecting any heat in the boiler. That means either the boiler is not heating or the sensor or sensor wire is detached from the boiler or the sensor has failed. The sensor is located behind the front display panel stuck in the front of the boiler and it has 2 thin wires in it with push on terminals.

Krups Coffee... | Answered on Jul 31, 2018 | 442 views


The valve in the lid is faulty, it will eventually fail completely. The correct lid can be ordered from your local Krups service agent. Be prepared for disappointment though as many of them are now obsolete. You will need to give the agent the model number, it's normally on a sticker on under the base.

Krups Coffee... | Answered on Jul 04, 2018 | 287 views


O sensor de temperatura na parte frontal da carca?a da caldeira (atr?s do painel frontal) n?o est? detectando nenhum calor na caldeira. Freq?entemente ? o borne de terminal desconectado do sensor ou o sensor inteiro n?o est? mais preso na caldeira. A solu??o da Krups ? para substituir a caldeira completa, mas no passado, eu revendi o terminal de volta ou colei (com cola resistente ao calor) o sensor de volta para a caldeira.

Krups Coffee... | Answered on Jun 11, 2018 | 72 views


A common place for a leak under the machine is the barista seal that goes in the bottom of the boiler around that eject rod. Barista seal part number is MS5002202, Seals on the tamping piston are MS5002040 (there can be 1 or 2 of these piston seals) If fixing the leaks does not fix error 6 then I expect it will end up being the distributor. Part number MS2A01500

Krups Coffee... | Answered on May 30, 2018 | 583 views


Did you completely finish the descale process. On the models I'm familiar with you run thru the descale doing every step it requests then refill the tank and run thru the rinsing process until it ends completely. As far as I know there is no reset for errors, the problem needs to be located and fixed. I have no idea what the unplug icon may be indicating.

Krups Coffee... | Answered on May 16, 2018 | 210 views


Probably going to depend on the model, ask another question and include the model number in the subject line to attract maximum attention

Krups Coffee... | Answered on May 07, 2018 | 1,683 views


The model is necessary information.

Krups Coffee... | Answered on Mar 22, 2018 | 470 views


First off you tell folks what model it is, then someone familiar with it will be able to help you.

Krups Coffee... | Answered on Mar 22, 2018 | 125 views


Replace the valve on the distributor or if necessary the whole distributor. While you are at it replace the tamping piston seals and the barista seal.

Krups Coffee... | Answered on Mar 22, 2018 | 137 views

Not finding what you are looking for?
Krups Small Appliances Espresso Machine Logo

298 questions posted

Ask a Question

Usually answered in minutes!

Top Krups Coffee Makers & Espresso Machines Experts

Charles Tidwell

Level 3 Expert

475 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Ross Keen

Level 3 Expert

1364 Answers

Are you a Krups Coffee Maker and Espresso Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...