Krups XP2000 Pump vibrates
You can try to put in a small bleeding resistor to push away the 30 Volts. However, this is not a proper solution.
Check where the 30 volts have it's origin. If you spot a false connection somewhere, fix this.
1/28/2019 1:35:18 PM •
Krups Coffee...
•
Answered
on Jan 28, 2019
•
259 views
My xp7240 water not come out
If you hear the pump is pumping then its not the pump you will probably have to open up the heater as it is full of water scale (calcium)
12/25/2018 11:33:34 AM •
Krups Coffee...
•
Answered
on Dec 25, 2018
•
170 views
Krups EA8108 70/70F factory reset. thaks
Try this, remove the tank, the drip tray, the bin on the side and the sliding thing above the bin. Hold down the on and steam buttons while plugging the machine into a live socket, it's either that or the same again but holding down the on button and the program button while plugging it in. You will get a screen that says something like " Remis a something vende" which is French for put it into sale state, you choose "Oui" for yes. It's been a long time since I've done one but that's as best as I can recall. It will zero the coffee counters as well.
11/28/2020 6:27:30 PM •
Krups Coffee...
•
Answered
on Nov 28, 2020
•
10,617 views
FNB3
????? ???? ese ??????????
10/20/2018 4:58:50 PM •
Krups Coffee...
•
Answered
on Oct 20, 2018
•
250 views
Error Code 9 on a Krups EA8000 Expresso machine
The heat sensor on the boiler is not detecting any temperature change. It could be a wire or terminal off. The sensor is right at the front of the boiler. If the sensor is faulty it means a new boiler because it's stuck on in the factory.
10/2/2018 6:44:51 PM •
Krups Coffee...
•
Answered
on Oct 02, 2018
•
936 views