20 Most Recent Mastercool 67680 Evaporative Cooler Air Conditioner - Page 2 Questions & Answers

0helpful
1answer

Master cool ll unit recycles

In most cases you will need to just adjust the float (grab the metal shaft and bend it downward) this will lower the water level. If this doesnt do it, then you probably need to replace the entire float assembly. This is normally a n easy and cheap thing to do.
5/29/2014 10:55:41 PM • Mastercool 67680... • Answered on May 29, 2014
0helpful
1answer

Swamp coolers

Does it come back on automatically and how long does it take?
5/16/2014 5:30:48 AM • Mastercool 67680... • Answered on May 16, 2014
0helpful
1answer

Can you usen the sam air vent for heating and swamp cooler

Yes you can. I have that set-up in my house. The only problem is when moisture laden swamp cooled air goes past the heat exchanger. This could cause the exchanger to rust out, allowing carbon monoxide to come into the house when the heater is used. This can be avoidid by having a one way damper made by an HVAC shop, and installing it at the heater.
4/29/2014 11:59:22 PM • Mastercool 67680... • Answered on Apr 29, 2014
0helpful
1answer

Loud clicking sound coming from evaporator and is not equiped with ignighter

Electrical issue. sounds like a bad relay, loose wire connection.
4/24/2014 1:07:06 PM • Mastercool 67680... • Answered on Apr 24, 2014
0helpful
1answer

High speed does not work but low speed does

If your motor only works on low speed and not on high speed first check to see if you have the proper voltage to high speed. Check with a voltmeter or multimeter, check from common on the motor to high speed on the motor at the switch. If you have the proper voltage then you have an open winding on high speed and the motor needs replaced. If you don’t have the proper voltage or any volts, then the switch is bad and needs replaced. This also will be the same if, medium speed won’t work and low speed does.
4/21/2014 8:23:12 PM • Mastercool 67680... • Answered on Apr 21, 2014
0helpful
1answer

The evaporative comes on but just idles and won't speed up making a noise and not blowing

Have you tried cleaning it? Because when mine wasn't doing what it was supposed to be doing i gave it a quick clean.
1/17/2014 12:54:57 AM • Mastercool 67680... • Answered on Jan 17, 2014
0helpful
1answer

2001 NISSAN SENTRA GXE HAVE CODES WITH INNOVA OBD2

I check the result of the three DTCs for you P1441 - NissanTypePowertrain - Manufacturer Controlled DTC - Manufacturer ControlledDescriptionEvaporative emission (EVAP) canister purge system - bypass vacuum cut valve malfunctionCauseWiring, EVAP bypass vacuum cut valve, EVAP cut valve/pressure sensor, hose leak/blockage, ECMP0455 - NissanTypePowertrain - Auxiliary Emission Controls - ISO/SAE ControlledDescriptionEvaporative emission (EVAP) canister purge system - gross leakCauseWiring, fuel tank/cap, hose leak/ blockage, EVAP valve/canister, EVAP vent valve, BARO sensor, MAP/BARO switching valve, ECMP1448 - NissanTypePowertrain - Manufacturer Controlled DTC - Manufacturer ControlledDescriptionEvaporative emission (EVAP) canister purge system - vent control valve malfunctionCauseWiring, EVAP vent valve, EVAP pressure sensor, hose leak/blockage, EVAP canister contaminated, EVAP vacuum cut valve, ECMhope these can help you, or you can ask the 24 hrs live technical support vas5054a, they will like to help you, good luck
9/16/2013 7:16:06 AM • Mastercool 67680... • Answered on Sep 16, 2013
0answers
0helpful
1answer

The belt on swamp cooler keeps breaking

Probably too tight or the bearings are going
9/3/2013 12:05:46 AM • Mastercool 67680... • Answered on Sep 03, 2013
0helpful
1answer

My master cool unit runs fine ...new bearings, and

Open it, and take take a look at the fan or for debris.
8/29/2013 10:45:15 PM • Mastercool 67680... • Answered on Aug 29, 2013
Not finding what you are looking for?
Mastercool 67680 Evaporative Cooler Air Conditioner Logo

242 questions posted

Ask a Question

Usually answered in minutes!

Top Mastercool Heating & Cooling Experts

azcruzaah

Level 1 Expert

3 Answers

Brad Brown

Level 3 Expert

19187 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Mastercool Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Mastercool Heating & Cooling

  • Mastercool Heating & Cooling

Most Popular Question

thermostate kicks pump motor ok but

  • Heating & Cooling
Loading...