Need a Honeywell remote (RT8220A) for my Vermont castings gas fireplace.
This was our first home in 2014, built un1981. Not sure when KozyHeat was installed. but since when within the last few days the remote and local seemed to disconnect completely. We tried several dozen times about the gas local to remote to pushing the flame button, all to no avail.
Is it the transmitter?
Is it the remote?
Is it something else?
We live in Northern Albrta, so it has been a little tricky to keep the heat in the house consistant.
Please reply with good news. A replacement or repair or anything?? Thank yoy!
11/10/2021 6:35:31 AM •
Honeywell...
•
Answered
on Nov 10, 2021
Honeywell hz322 board is blank with no lights on but is receiving power.
If the board isn’t shorted out then a damper or tstat is. I would first take a pic of all the wiring, turn power off and remove all damper wires. Turn power on and see if you get any lights. If yes then you can eliminate one damper at a time to find problem. If no lights, turn power off, remove remaining wires other than the transformer wire that provides power to board and then power on. If you get lights then you likely have a tstat issue. If still no lights you have a bad zone panel.
11/1/2021 9:00:23 PM •
Honeywell...
•
Answered
on Nov 01, 2021
Ive currently got a honeywell
There are other universal replacements but if it was me I would stick with the honeywell parts. I know they are more expensive but in your instance where you already have a problem that is causing the control panels to fail I'm afraid you would make it worse by using other then factory replacements.Thank you
10/10/2021 3:12:59 PM •
Honeywell...
•
Answered
on Oct 10, 2021
Honeywell Thermostat backlight TH8320u 1008
I have not seen this issue and the manual gives you the option of either off or dim to high upon key depress.
Manual:
0280 Backlight 0 Backlight on for approx. 8 seconds after keypress 1 Backlight always on low intensity, full bright after keypress (requires 24VAC connection).
I am sorry I can not offer any further info.
8/17/2021 12:45:47 AM •
Honeywell...
•
Answered
on Aug 17, 2021