Toshiba estudio 2006 backgrond dark in print copy.please solved thise problem
Did you use the original toner and original drum?
Toner high in developer.
While pressing [0] and [5] simultaneously, turn the power ON. The following message will be displayed.
Key in code [2000] and press the [START] button. The display changes as follows.
Indicates the controlled value of the auto-toner sensor output. Press the Up or Down button to change the value.(245,128)
Please the OK button.
Toshiba e studio e 450 EROO CE50 - Toshiba Printers & Copiers
[CE50] Temperature/humidity sensor abnormality
Is the connector CN317 on the LGC board or th
e connector of the temperature/humidity sen-
sor disconnected?
Is the harness between the LGC board and the temperature/humidity sensor disconnected?
?
YES
?
Connect the connector securely. Replace the harness.
NO
1) Replace the temperature/humidity sensor.
2) Replace the LGC board.
C45 error in toshiba estudio 4530c
[C450]
Abnormal temperature difference between the center thermopile and the edge thermistor (Not determined)
Reset error code 08-400=0
Check fuser unit, power supply unit, thermopile, LGC board.