Maytag M6Y12F2A Air Conditioner - Page 9 Questions & Answers
Thermostat went off. Checked
Is this a portable air conditioner? If so then the water needs to be dumped out of the reservoir and normal operation should ensue.
I have a window air
Hello, I looked that part up but it looks like it is discontinued by the manufacturer. Here is a link to the website http://www.repairclinic.com/Shop-For-Parts?s=t-M6T12F2H-==
THE FAN MOTOR NEEDS TO BE REPLACED THAT BLOWS OUT
Hi!!
I recon you are talking about a fridge, you'll need the model of your unit. Once you get that info, click on the following link and enter the info to find your part.
http://www.repairclinic.com/ Here are the locations where you can find and order the Part. If you have any trouble locating the part, provide the unit's model and I'll help you find it.
Good Luck!! A HELPFUL - 4 THUMBS - rating for this solution would be greatly appreciated. Thank you for using FixYa.
Fan does not run on high speed .
dear sir
if you how know to read a electric tester then check you air con,s selector switch please find out the fan motor wire in selector switch and test one by one and turn to fan on high speed mode and check on selector switch there electric supply comes on selector switch if it,s come and motor doesn't work then it,s mean motor high speed is defective if supply not come on selector switch then it,s mean selector swith is faulty .
if you can check like this then do if not then contact to a technician,
thank you
hope answer the question
please vote1
Our 5 year old maytag
maytag is still made and you can call dale supply in knoxville,tn and they can fix you up
Bought A/C in 2006. Used 1 yr - worked OK. Idle
Make sure there is no restrictions in the coils front or back. If the units compressor is running and was just low on freon it will ice up on the inside coil. If the compressor is not running it could be the temp switch or the capacitor. Make sure you have 220v at the plug in if its a 220 unit. Maytags are good units so look for hits on the coils that happened in installation or while stored if you see a obviouse dent ect... and its dirty or oily you may have popped a line and lost your freon. I hope this helps goodluck
We have a Maytag air
If the unit is in a room smaller than it should be it can cycle too quick.
If the air blowing out is too near the thermostat in the return air it can cycle too often.
The thermostat could be defective. It could be set for too narrow a range of temp which is not adjustable. Try it at different settings to see if that makes a difference.