How may capacitors are there in LG split ac 1.5 ton unit

At least 3. 1 on the inside unit fan, 1 on the outside unit fan and 1 on the compressor. The outside unit may have both in a single chassis.
8/15/2016 6:05:01 PM • LG Electronic... • Answered on Aug 15, 2016 • 247 views
0helpful
1answer

Hitachi error codes p5

You have to try resetting the system. First turn the breaker off for the condenser and wait about 20 seconds. After you turn it back on the system should reset. West Palm Beach Air Conditioning
8/15/2016 10:30:04 AM • LG Electronic... • Answered on Aug 15, 2016 • 2,441 views
0helpful
1answer

Window a/c thermistor or control/circuite board replacement?

Still could be the fan capacitor. You cannot visually inspect a capacitor. It needs to be tested with a dvm. Beware capacitors store quite a bit of juice and although they probably won't cause permanent damage....the do hurt like hell when the discharge into you. You could try with the unit running spinning the fan manually BE CAREFUL. If it starts then the cap is probably bad. If not motor could be bad even if it spins ok.
7/19/2016 4:50:19 PM • LG Electronic... • Answered on Jul 19, 2016 • 95 views
0helpful
1answer

My LG window air conditioner is spitting out water

randobrad had it exactly for me, the port to the outside was cleared but the one from front to back was clogged. Once I found the small port (using a wire hanger) it was easy.
11/22/2018 1:53:17 PM • LG Electronic... • Answered on Nov 22, 2018 • 10,765 views
0helpful
1answer

How do i troubleshoot lg lw 8013er window unit

remove filter and see if coil froze up. that will slow down air flow.
8/8/2015 5:15:44 PM • LG Electronic... • Answered on Aug 08, 2015 • 105 views
0helpful
1answer

Lg window air conditioner makes a whistling noise

Try putting a hand on the grill while it's running to see if it dampens the noise.
7/15/2015 1:20:46 AM • LG Electronic... • Answered on Jul 15, 2015 • 2,132 views
0helpful
1answer

Swing motor not working

These are quite easily damaged and sometimes just wear out. The cable from the motor can also be easily damaged. They are cheap and easy to replace. Just source a new one for that model online. When you receive it, turn off power to the system, take the front cover off, unscrew inside tray from cover box, slide tray out, remove the power box, get access to the motor and replace. Be sure to check which wires go where before removing and take photos or make accurate diagrams with color codes. Check that the control board functions normally before purchase though. A faulty board could cause this fault.
7/3/2015 12:05:25 PM • LG Electronic... • Answered on Jul 03, 2015 • 559 views
0helpful
1answer

After turning off the unit the display is off but the unit is still running.

If it has humidity control and the cool is still on but set temp is higher than the room temp, the humidity control will override set temp. If it has no %rh control then it probably has a circuit board fault; micro relay is stuck closed and board needs to be replaced. Its probably the circuit board. On it, there is a little black box(s). About 1" X 1/2" in size. With long run times the small contacts inside will fuse/melt together.
6/20/2015 11:54:45 PM • LG Electronic... • Answered on Jun 20, 2015 • 92 views
0helpful
1answer

PROBLEM ON START WINDOW AC

Lg have 5uf capacitor installed in outdoor section along with comoressor unit. It bascially helps to rotate the condenser fan.
3/15/2014 4:00:05 PM • LG Electronic... • Answered on Mar 15, 2014 • 115 views
0helpful
1answer

Recharge freon banded

Yes. If it has a port installed from factory, it can be recharged. If it used R12, it can be purchased from Ebay. It the unit does not have a recharging port, you can also purchase that from Ebay. You need to know the size of tubing the port is going on. A pressure guage would also help troubleshooting.
1/20/2014 5:10:25 PM • LG Electronic... • Answered on Jan 20, 2014 • 136 views
0helpful
1answer

OUT DOOR conditioners RUNNING CONTINUE WHAT IS PROBLEM, AND HOW IS SOLUBLE.

Is the fan running?
1/20/2014 5:05:31 PM • LG Electronic... • Answered on Jan 20, 2014 • 43 views
0helpful
1answer

My 18000 btu unit is brand new and when I plug it

First of all you need to check if your power supply to unit is correct (120v or 220v).
11/11/2013 1:58:35 AM • LG Electronic... • Answered on Nov 11, 2013 • 125 views
0helpful
2answers

I need to know the symbols on remote and what every symbol means?

Hi,

The model number seems to be for a wall mount unit. here si the link for the manual:

http://www.pt.hu/application/document/download/1244055252_b2bec98a0010140ead0936e6ea9d75d6/JLA_LLA_PART_LIST.pdf

I hope this helps.
4/18/2013 2:55:10 AM • LG Electronic... • Answered on Apr 18, 2013 • 1,948 views
0helpful
2answers

LG Air Conditioner/Heat Unit spits cold air

I believe the "FP" probably stands for Freeze Protection and it's there to prevent your outside coil from freezing up and causing your head pressure to drop. To do this, it briefly has to reverse the cycle from heating to cooling. This is normal in a heat pump.
2/9/2013 9:34:02 PM • LG Electronic... • Answered on Feb 09, 2013 • 448 views
0helpful
1answer

Dropped air conditoner 2nd storie now hissing what to do with it

wait for it to bleed off then scrap it.usually not worth repair and recharge
9/27/2012 5:05:47 PM • LG Electronic... • Answered on Sep 27, 2012 • 53 views
0helpful
1answer

Breaker Trips Immediately

Have a short in unit. Need to check continuity of each component to ground to determine where short is. Also make sure breaker is good.
8/30/2012 9:49:29 PM • LG Electronic... • Answered on Aug 30, 2012 • 166 views
0helpful
1answer

Lg window unit digital problem cutting on and off

Air sensor defective replace it.
8/18/2012 12:38:10 PM • LG Electronic... • Answered on Aug 18, 2012 • 62 views
0helpful
1answer

Unit cutting off and on

If you have set the temp near to the room temp it will switch off and on. Set it to to 20 deg and watch. Even if it is not working properly then problem is with thermostat.S.S.MALICK
8/3/2012 1:30:51 PM • LG Electronic... • Answered on Aug 03, 2012 • 58 views
0helpful
1answer
0helpful
1answer

Water is coming out of the vent

Sounds like the drainage tube is stopped up or the canal. That should take care of your problem.
7/22/2012 6:28:42 PM • LG Electronic... • Answered on Jul 22, 2012 • 42 views
Not finding what you are looking for?
LG Electronic Window Air Conditioner Logo

178 questions posted

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

MattS1978

Level 1 Expert

7 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...