20 Most Recent Ruud Central System Air Conditioner - Page 3 Questions & Answers

0helpful
1answer

Rtea-60-acu

5 ton
8/2/2014 3:52:25 AM • Ruud Central... • Answered on Aug 02, 2014
0helpful
1answer

Why would unit be leaking water on the inside unit

If it is leaking on the inside (coil) it usually is a sign the condensate drain is plugged causing overflow, or the coil is freezing up inside and when its off it thaws the ice and melts down the center of the coil and onto the floor,
7/21/2014 2:46:53 PM • Ruud Central... • Answered on Jul 21, 2014
0helpful
1answer

Will a bad ac thermostat blow a 5 amp fuse

It could check for chafed wireing
7/19/2014 2:22:56 AM • Ruud Central... • Answered on Jul 19, 2014
0helpful
2answers

Unit not blowing cold air. Outside compressor and fan not running. Outside computer board has flashing red light.

Onboard diagnostic indicates 24VAC is still being supplied from the furnace.....should be a code on the inner cover or available online. Start with 220V service to the condensing unit once the diagnostic is resolved.
6/10/2014 10:47:27 PM • Ruud Central... • Answered on Jun 10, 2014
0helpful
1answer

How can i find the electrical diagram of split condionner mdel kfr-33gw/j ?

There are service manuals here for the 33GW/C and /D. I have not been able to find one for the /K, sorry. Hope this helps anyway. Warning: The manuals are big and take a few minutes to download. They're also in Japanese but the pictures are good. Good luck! HITACHI Air conditioner Manuals
5/20/2014 10:07:34 PM • Ruud Central... • Answered on May 20, 2014
0helpful
1answer

Replace contactor

On single phase your incoming power lines go to L-1 & L-2, the lines to the compressor go to T-1 & T-2. With A/C current it does not matter which one goes to which side as long as the line goes to the L side and the compressor power lines go to the T side. As long as the coil voltage is correct any contactor will replace the original.
4/23/2014 12:39:51 PM • Ruud Central... • Answered on Apr 23, 2014
0helpful
1answer

Electric heater blows cool air unless i turn the thremostat up at least 5 degrees higher then it goes to high and blows warm air

If it's "dual fuel" like heat pump with gas heat, the heat on the heat-pump side won't "feel" warm in the extreme temperatures we've seen in much of the country lately.....2nd stage gas will feel MUCH warmer. If purely electric, 1st stage heat may be off due to a manually resettable high limit switch/ bad heat contactor (giant relay), or a misapplied or defective thermostat. NOTE: if somebody recently painted OR wallpapered, AND it's a mercury-bulb T-stat, It HAS to be level and the connections must be tight!
1/28/2014 11:15:39 PM • Ruud Central... • Answered on Jan 28, 2014
0helpful
2answers

I need assistance with swapping out a contactor.

I don’t believe changing the contactor to a double pole contactor will solve this problem. It appears by your description that bugs are being attracted to the contact points on the contactor. Changing to a double pole contactor will not eliminate that problem but only provide another contact point for the bugs to be attracted to. The most effective solution would be to replace the current contactor with a sealed design where the contact points are totally enclosed. Enclosed contactors are completely enclosed protecting it from bugs and dirt. These type of contactors are available in the single pole design so no further wiring modifications are needed. You can consult a professional A/C service company like mine for more information and assistance.

Hope this helps. Let me know if there's anything I can do for you!

Sam, The Service Expert
Visit Sam's Blog

1.888.HEATCOOL
ServiceExperts.com
1/6/2014 3:15:26 PM • Ruud Central... • Answered on Jan 06, 2014
0helpful
1answer

My heat pump will not heat, but A/C works and

Sounds like a problem with the reversing valve. I had a two y/o heatpump system have a reversing valve fail. The entire valve assy had to be replaced. This is NOT a DIY job. You have to recapture the refrigerant and then unsolder the reversing valve and resolder a new one in and test for leaks and purge the air from the lines before recharging the system. Really NOT a DIY job...
11/5/2013 3:12:22 AM • Ruud Central... • Answered on Nov 05, 2013
0helpful
1answer

My furnace keep cutting off

1 blink usually indicates ignition failure. if burners are lighting then cutting off, watch for amber light ( flame) on board, if its not lighting up, then flame sensor needs to be cleaned or replaced.
10/27/2013 9:38:22 PM • Ruud Central... • Answered on Oct 27, 2013
0helpful
1answer

Thermostat error message "system Busy"

sounds like you have a communicating system, look for your user manual, probably near the indoor system.
10/17/2013 7:54:50 PM • Ruud Central... • Answered on Oct 17, 2013
0helpful
1answer

Fans don't spin spin when air is on. no cool air

change the run capacitor on the condensing fan motor
9/7/2013 5:45:50 PM • Ruud Central... • Answered on Sep 07, 2013
0helpful
1answer

What are the filter sizes on this unit

Measure the dimension of the filter compartment in the air handler or look at the ones in the air handler for the dimensions printed on them.
9/1/2013 6:10:26 AM • Ruud Central... • Answered on Sep 01, 2013
0helpful
1answer

What is the filter size for a model # TWE090A300EL

Either measure the filter port on the air handler or match the size printed on the existing one
8/29/2013 10:26:44 PM • Ruud Central... • Answered on Aug 29, 2013
0helpful
1answer

Outside central air unit: I noticed the fan was

The fan motor is thermally protected the motor seems to be cutting out on the overload replace the fan motor
8/22/2013 8:34:03 PM • Ruud Central... • Answered on Aug 22, 2013
0answers
0answers
0helpful
4answers

Ruud furnace won't stay lit.

Hi, welcome to Fixya. If you have spark ignition turn off the power and using sand cloth clean the rod(s) and hood of the spark ignition. If it is a Hot Surface Igniter (glow coil) look on the opposite end of the burners and you will see a rod protruding in to the flame. It's called a flame sensor. Clean it with the sanding cloth. If either of these works then you bought some time but should consider replacing the part fairly soon. Please report back to let us know your progress. Good luck.
2/16/2013 7:54:24 PM • Ruud Central... • Answered on Feb 16, 2013
Not finding what you are looking for?
Ruud Central System Air Conditioner Logo

288 questions posted

Ask a Question

Usually answered in minutes!

Top Ruud Heating & Cooling Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Ruud Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Ruud Heating & Cooling

  • Ruud Heating & Cooling

Most Popular Question

find electrical diagram split condionner

  • Heating & Cooling
Loading...