Weather king 10AJB30A01 runs but doesn't cool
Hello, in order to find the leak usually a dye is injected into the system and will pinpoint exactly where a leak is. If the condenser is leaking your better off replacing it then trying to spot braze it. The ductwork needs to be supported properly with very little restriction so the air csn move freely. Flex duct has a tendecynto tear or come apart so it needs to be checked over and repaired if you see it torn or sagging anywhere.
5/11/2012 3:27:36 AM •
Weather King...
•
Answered
on May 11, 2012
•
707 views
Weather King 10aja1801
The answer is yes however you will want to change the indoor coil in the furnace also.
You would look for a 1.5 ton matched set.
7/19/2010 10:47:27 PM •
Weather King...
•
Answered
on Jul 19, 2010
•
565 views
Furnace lights but flame goes out almost immediatley
It's the limit switch that is located on the fire box. There are two wires that go to a disk about the size of a penny and in between the two wires is a very small button. This button resets the limit. If this switch is tripped, the flame will immediately go out to protect you from carbon monoxide poisoning and possible fire. If it will not reset, then take the two wires off and use another piece of wire to jump the switch. If it lights, then you know that the limit is bad. If not, then there are a few more to find. There could be 2 to 3 of these on the fire box and there is usually one near the inducer or on the inducer.
4/4/2009 2:36:50 AM •
Weather King...
•
Answered
on Apr 04, 2009
•
263 views
Screaming Weatherking Heatpump!
If the scream is something new...have tech look at it. You've got problems coming and you don't want that on a really cold day.
11/23/2008 3:42:42 AM •
Weather King...
•
Answered
on Nov 23, 2008
•
295 views