20 Most Recent Frigidaire FAC124 wall/Window Air Conditioner - Page 7 Questions & Answers

0helpful
1answer

Frigidaire window A/C unit lowers temp to 60 on its own and beeps??? What does this mean?

means you need to replace the panel
7/2/2016 12:31:39 AM • Frigidaire... • Answered on Jul 02, 2016
0helpful
1answer

Frigidaire lra157mt1

Some of the new style Air conditioners have a auto time delay built into them for power failures. If power fails or you unplug the unit, they will not come back on for about 3 to 5 minutes. This is a safety feature to keep power failures from damaging the compressor. Keep it plugged in for 5 minutes and try again. If still no go then call for service. You should have a 1 year warranty on it.
6/19/2016 9:57:07 PM • Frigidaire... • Answered on Jun 19, 2016
0helpful
1answer

Window unit wiring

If these are part of your replacement piece chances are it's an upgraded board with optional accessories. If you only had 2 before go with 2 now. Wire nut extra wires and zip tie tight. Should be ok. If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79
6/12/2016 11:51:04 AM • Frigidaire... • Answered on Jun 12, 2016
0helpful
1answer

Clean window ac unit

What do you need to know about cleaning your wall unit? If you need any other assistance check us out online at Boca AC Service we are always happy to lend a helping hand.
6/2/2016 7:40:31 PM • Frigidaire... • Answered on Jun 02, 2016
0answers
0helpful
1answer

I have my brand new frigidaire window ac unit set at 60 degrees Fahrenheit, so why does it only cool and keep the room at 65 to 68 degrees Fahrenheit?

if you have it set at 60 F and it is working at 65 to 68 F then that would be about right as the air is cooled the cold air falls to the floor and out under the door, open window or anywhere else it can escape the unit has to be at 80% room height so if it is set in a window then when the cold air gets up to the thermostat or ac level in the window then it will stop cooling So if the ac unit is say 4ft from the floor and the ceiling height is 8 ft then the ac will only cool the bottom 4 ft cold air does not rise but falls down if you are using a ceiling fan then the cold air is stirred up and the 65F sounds about right remember that the setting temp ( what you set it at) is the lowest temp that it will go down to before it stops cooling and if that is not reached it will keep working to attain that temp and if the room is too big, air leaks under door . around the fit in the window , no insulated walls , hot exterior wall,etc then maybe 65 F is the best you will get
5/9/2016 4:52:44 AM • Frigidaire... • Answered on May 09, 2016
0helpful
2answers

Water doens't drain properly and sitting there,

that's fairly common for window units, it's ok to drill a small hole in the underside of the case to drain the water, just be sure you don't puncture the condenser in the process.
5/7/2016 4:28:38 AM • Frigidaire... • Answered on May 07, 2016
0helpful
1answer

Air conditioner will not start, but it does beep like it has a shortage

Change the compressor capacitor
4/30/2016 11:46:09 AM • Frigidaire... • Answered on Apr 30, 2016
0helpful
1answer

Where is the condensate line on a Frigidaire wall air conditioner?

There is sometimes a plastic hose between the evaporator and condenser side on the bottom of the case. Other models simply have holes in the metal for condensate to drain into the condenser side . Make sure there is no obstruction to the hose or holes. If you find none, then check the level of the unit. It MUST be slanted so the back of the unit is lower than the front.
3/11/2016 9:19:53 PM • Frigidaire... • Answered on Mar 11, 2016
0helpful
1answer

Model FAZ12HS2A. When in Heat mode, why does it blow cool air?

Hello J, thanks for your post!

I see that your Frigidaire air conditioner is not emitting the proper air when in heat mode. I would recommend performing a reset on your air conditioner and you can do that by disconnecting the power cord. Once you have removed the power cord, press the reset button and then the test button. You should then be able to plug it back into the wall and start it up. If you continue to have issue with it an electrical component may need to be replaced and I would recommend this be completed by a professional technician. They would have the knowledge on how to properly disassemble the air conditioner without any harm. Good luck! -Matt

1/7/2016 4:46:24 PM • Frigidaire... • Answered on Jan 07, 2016
0helpful
2answers

My unit blows out black soot looking stuff, and it smears when touched, and my filter is clean. What is it? And how can I get it to stop?

Carol, the first thing I would suspect would be mold in the insulation within the blower compartment. Sometimes the cooling coil overflows, causing the fibreglas insulation to get wet which in turn allows mildew/mold to form in that compartment. Severe cases will sometimes discharge nasty stuff as you describe coming out of the ducts. Turn off the power and remove the blower compartment cover and investigate.
10/4/2015 2:53:37 AM • Frigidaire... • Answered on Oct 04, 2015
0helpful
1answer

My frigidaire air conditioner is making my apartment feel damp and when i took my filter out to clean it that part was damp too! What do I do to fix this?

You may have a clogged drain or the unit is installed without enough angle pitch for the water to drain to the back of the unit toward the outdoor section of the unit. I'm assuming it's a window air conditioner? The moisture condenses on the cooling coil near the filter and should drip down into a condensate drain pan, then the water should drain to the back of the unit into a pan at the condenser coil fan that is rejecting the heat outside. The fan blade usually has a ring on the outdoor fan that pick up the condensate moisture the fling accumulated water onto the hot condenser coil to evaporate it. Also the filter should not be touching the cooling coil. Make sure it in the correct slot. Some a/c cooling coil require a wetting agent that allow the water to slide down the coil and not pull off of the coil into the indoor circulating fan.
9/11/2015 11:28:30 PM • Frigidaire... • Answered on Sep 11, 2015
0helpful
3answers

Touch pad not working

you should call frigidair because thay have people that can come and look at it
8/16/2015 12:38:41 AM • Frigidaire... • Answered on Aug 16, 2015
0helpful
1answer

Breaker keeps going when plugging the cord in the outlet

the outlet itself may be miswired with the line(hot) and neutral reversed. simple plug in tester will tell you if that is the issue, among other things. usually under $4 for the tester.
8/6/2015 4:56:04 AM • Frigidaire... • Answered on Aug 06, 2015
0helpful
1answer

18000 btu fan comes on and runs for about 10 seconds stops lights on front panel flashes and stops ac unit was new and ran fine but been in storage for about 1 year and now has problem

Frigidaire Window Air Conditioner Part I - YouTube

? 5:01 www.youtube.com/watch?v=M40T8UgMs6I Apr 29, 2009 - Uploaded by gusherb94 Here is my Frigidaire window air conditioner and I'm demonstrating it's operation with a Kill-A-Watt plug ...
8/4/2015 8:00:22 PM • Frigidaire... • Answered on Aug 04, 2015
Not finding what you are looking for?
Frigidaire FAC124 wall/Window Air Conditioner Logo

Popular Tags

74 questions posted

Ask a Question

Usually answered in minutes!

Top Frigidaire Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8221 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6963 Answers

Steve Oakes
Steve Oakes

Level 2 Expert

234 Answers

Are you a Frigidaire Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Frigidaire Heating & Cooling

  • Frigidaire Heating & Cooling

Most Popular Question

frigidaire air conditioners spit

  • Heating & Cooling
Loading...