Amana Side-By-Side Refrigerator 26 cu. ft. - ASD2622HR - Page 8 Questions & Answers
Amana model TSI19TW Stopped working no light
you could have a bad timer or cold control and the light could have failed from the heat but try banging on the control,not to hard,it can stick when it fails and sometimes a good wack will get it going the timer is also there where the cold control is,there's a hole below the timer,if you stick a flat head regular screw driver up in there you can turn the timer out of defrost, just one or two clicks,if everything starts to run the timer is bad but i would check them if you unplugged the fridge and plugged something else in the plug to make sure you have power there
2/6/2018 5:28:19 PM •
Amana...
•
Answered
on Feb 06, 2018
I have an Amana model
Think of a water faucet.. You turn it on and water comes out and you turn it off and the water stops, right? Now when a faucet gets old sometimes it will drip and you have to jiggle it to make it stop.
In the back of the fridge you have the same basic thing. A valve that opens and closes to allow water to flow.. It is split into two sides, one for the water in the door and one for the icemaker.
One side could go bad while the other still works and that sounds like what is happening. Some have one and some have two depending on if you have a water filter but this one looks to be an oldie but goodie before the water filters were factory installed.
The part# you need is WPW10247599 and I fount it for under 40$. You need to unplug the unit and turn off the water to it. Change the valve and defrost the tube going to the icemaker.repair if needed.
1/28/2018 8:38:40 PM •
Amana...
•
Answered
on Jan 28, 2018
Amana refrigerator not cooling, what should be done or what should we check to determine the problem?
The purpose of a refrigeration circuit is to move heat from the inside of the cabinet to the outside.
The compressor pumps refrigerant around the circuit and if everything is ok the evaporator is cold and the condenser becomes warm. If the compressor is running but nothing inside or outside is happening either the compressor is defective or the refrigerant has leaked away.
If the condenser is warm or hot but the inside is not cold the defrosting panel might be permanently switched on.
11/27/2017 4:21:06 AM •
Amana...
•
Answered
on Nov 27, 2017