20 Most Recent Hunter Ceiling Fan Light Remote Control - Page 7 Questions & Answers

0helpful
23answers

Fan lights just started blinking, we changed bulbs

This problem was posted on several sites, but this was the only one where I found both the cause of the problem and the solution. Mine is a Hunter 5 Minute Fan which came with no remote. And after about a month the two lights would blink together whenever I'd turn them on at the wall. So in case it helps for that type of fan or the same type of wiring arrangment here is what I did: POSITIVE SIDE: P1) Remove the light shade. P2) Remove the 3 screws that hold the cowel and lower the cowel. P3) Disconnect (pull apart) the black and red wire coupling. P4) Cut the coupling off of the black wire that comes up from the lights. P5) Strip off a quarter inch of jacket from that black wire. P6) Remove the wire nut that connects the black wire coming from the governor with the other black wire. P7) Re-use the wire nut to connect the black wire from step P5 with the other black wire from step P6. NEGATIVE SIDE: N1) Disconnect (pull apart) the white to white wire coupling. N2) Cut the coupling off of the white wire that comes up from the lights. N3) Strip off a quarter inch of jacket from that white wire. N4) Remove the wire nut that connects the white wire coming from the governor with three other white wires. N5) Set the governor aside (or just throw it away). N6) Re-use the wire nut to connect the white wire from step N3 with the other white wires from step N4. That's all, you're pretty much done! Turn on the power and test the light. If all is good, re-install the cowel and the light shade.
11/26/2022 12:27:41 AM • Hunter Dryers • Answered on Nov 26, 2022
0helpful
2answers

I have. Hunter model 99122. How do you reverse the fan direction with the remote

If you have this kind, it is actually INSIDE the lighting housing. Remove the glass dome, and there is a little slide switch next to one of the bulbs. Such a bad design, but, yeah . . . .
1_26_2019_9_58_00_pm.jpg
4/24/2022 8:21:58 PM • Hunter Dryers • Answered on Apr 24, 2022
0helpful
1answer

My Light kit has quit working, do I need a new wiring harness?

1. batteries in remote is bad 2 remote is bad 3 receiver located in ceiling canopy of fan is bad. you can buy remotes and receivers on line
4/23/2022 2:01:15 PM • Hunter Dryers • Answered on Apr 23, 2022
0helpful
1answer

I have a Hunter air purifier model 30010 and it's fan is making noise. I cannot find any way to take it apart to see if I can clean the fan assembly or WD-40 it. Even YouTube has nothing. Ideas?

Looking at the images, I would imagine there are screws in deep sockets accessed from the base that hold the top and bottom section together. Sometimes they are hidden under rubber feet or under small removable plastic plugs. https://www.google.com/search?q=hunter+air+purifier+model+30010+disassembly ..
4/18/2022 10:31:07 PM • Hunter Dryers • Answered on Apr 18, 2022
0helpful
1answer

How do I reverse direction of hunter fan model 99119

if it is reversable it should have a black square button on the side of the hub make sure it is stopped before you try to move switch position.
4/15/2022 1:32:15 PM • Hunter Dryers • Answered on Apr 15, 2022
0helpful
1answer

Where can I find a replacement part ZE-301 B or E92501 for a light socket on a Hunter ceiling fan

https://www.ceilingfanswitch.com/product/zing-ear-ze-301b-lampholder/
3/19/2022 8:37:13 PM • Hunter Dryers • Answered on Mar 19, 2022
0helpful
1answer

How To oil hunter fan catalog 22272-004. Can't find my 1980 owners manual which used to give instructions.

Checking OilCheck oil level immediately after fill- ing the reservoir. To check oil, bend an ordinary pipe cleaner into a 1/2" long hook and dip it into the oil reser- voir. If oil touches the end of the pipe cleaner, the fan has ample oil. If it does not touch, add SAE 10 non-detergent oil slowly until it touches the pipe cleaner.Your Original Hunter's unique lubricating systemThe bearings are submerged in a bath of oil. The oil moves up a spiral groove in the shaft, lubricating all bearing surfaces as the fan operates. This Lubrication System does not normally "use up" or require the addition of extra oil once the oil reservoir has been filled to the correct level. This unique lubrication system is one reason your Original Hunter Ceiling Fan will last a lifetime. It is highly unlikely that you will ever need to add oil to your Original fan once it is installed. Should you move your fan to another location, it is a good idea to check the oil reservoir. Hunter has developed an accessory 'Original Relocation Kit' that includes all mounting hardware and a fresh tube of oil for this reason. The model number is 22360.CAUTION: DO NOT TURN FAN ON UNTIL LUBRICATION HAS BEEN ADDED. TO OPERATE THE FAN WITHOUT OIL OR WITH LOW OIL WILL VOID YOUR WARRANTY Adding oilYour fan has been shipped withoutoil in the motor. A 1-ounce tube ofhigh grade SAE 10 non-detergent oilis packaged in the sack parts. All theoil in the tube must be put into thefan. Cut the tip off the tube and place the tube into the oil hole. To avoid overflowing during filling, allow oil to gravity flow about one minute to fill the oil reservoir. (It may be necessary to puncture the tube to allow air in.)
11/16/2021 5:10:08 AM • Hunter Dryers • Answered on Nov 16, 2021
0helpful
1answer

Is a 4 uf 250 an acceptable replacement for a 4 uf 350 on a hunter fan

Since I cannot see the fan I will take a safe answer and say probably not. The manufacturer spent more for the 350V capacitor, they had a reason. You can go to a higher voltage that would be OK.
10/2/2021 4:08:58 AM • Hunter Dryers • Answered on Oct 02, 2021
0helpful
1answer

Replacement for hunter ceiling fan remote 85095

I would try searching on the companies official website to see if they have a remote for your ceiling fan.Amazon may also have a remote too for your fan and EBay.
8/10/2021 8:10:37 PM • Hunter Dryers • Answered on Aug 10, 2021
0helpful
1answer

The rocker switch next to the hunter switch works the lower light kit and the little bottom switch on hunter switch turns on upper light on fan but nothing else on hunter switch seems to work. 27186

You installed the 27186 to control an existing fan? It's a three speed pull chain fan? Yes and yes,, the fan pull chain must be in high speed.
3/14/2021 12:48:15 AM • Hunter Dryers • Answered on Mar 14, 2021
0helpful
1answer

I am replacing my thermostat to a Hunter 44905 thermostat Can you tell me where my four wires goes into the hunter, from the wall is red,white ,green and blue.

Unfortunately, the time to check where the wires go was when you removed them from your old thermostat. You need to match the pattern of the original thermostat to the HVAC (heat pump, furnace or other) system. Try going to your HVAC system's main inside box and opening the cover. Try to find the wiring connections to the control board. (This will be inside of the filter on most systems.) Take a picture or otherwise record which color wire goes to which letter terminal. I do not expect the wiring color pattern to be consistent over all the different types of heating and cooling systems installed by different companies. In the package with your new thermostat, you may probably have little adhesive labels with lettering like Y, G, Rh, Rc, W. Take the appropriate label and secure it to the matching color wire as noted at the control board of the HVAC system. Then connect the wires to the matching letter locations on the new thermostat. (Modify any jumpers on the thermostat based on the installation directions.) I hope this helps. Cindy Wells (I know that on my system (gas furnace and A/C forced air), there is an outside cover, the filter, and then an interior cover to access the control board. The board is near the bottom of the compartment.)
2/17/2021 12:05:39 AM • Hunter Dryers • Answered on Feb 17, 2021
0helpful
1answer

HUNTER IRRIGATION CONTROL SBC PLUS

Your issue is ...........................................
1/21/2021 5:22:22 PM • Hunter Dryers • Answered on Jan 21, 2021
0helpful
1answer

Up and down buttons won't work on Hunter thermostat 44110. Other buttons seem to work fine.

Could be the membrane and may need replacing.
12/1/2020 4:32:48 PM • Hunter Dryers • Answered on Dec 01, 2020
0helpful
1answer

My Hunter fan using remote 85095-01 will not reverse ceiling fan direction.

Free online manual gives a suggestion that you may already tried to select the fan speed, and then click on the reverse button. Some ceiling fans also have a cord to pull to reverse direction, but unknown whether or not your fan has it. https://www.manualslib.com/manual/808927/Hunter-85095.html?page=2
5/26/2020 1:15:45 PM • Hunter Dryers • Answered on May 26, 2020
0helpful
1answer

Hunter fan model 52047 fan but works light doesn't work brand new install

Double check power at the blue wire (light).
5/12/2020 11:29:22 AM • Hunter Dryers • Answered on May 12, 2020
Not finding what you are looking for?
Dryers Logo

149 questions posted

Ask a Question

Usually answered in minutes!

Top Hunter Dryers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Paul Bade

Level 3 Expert

1818 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Are you a Hunter Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Hunter Dryers

  • Hunter Dryers

Most Popular Question

hunter fan 27227 remote stopped working

  • Dryers
Loading...