Question

  • 7,646 People Helped

Reddy Heater will not ignite flame

Have an older Reddy Heater Pro 110. Some years ago it was being used and ran out of K1 fuel while being used. If you plug it into the outlet (with a full tank of K1) only the fan works. Looking for suggestions about fixing the heater. I did take apart the heater and the only thing that I can see could be wrong is a black "box" under the fan (ignitor starter circuit) or somewhere there is a fuse or maybe a pump failure ? Has anyone had this problem ? Thanks.

Posted by on

Answer

  • Most Helpful of 3 Answers

Please answer the following questions. There are several folks on the board that can help but we need to know some vital information so we can get started. Answer these, if you can:

  1. Which Pro 110 do you have. We need the exact model number. Pro 110 is a series of heaters.
  2. Does the heater have a spark plug or a glowbar (HSI)?
  3. When the motor runs is it pumping fuel?
  4. When the motor runs is the spark plug firing (or glowbar glowing)?

Posted on Nov 13, 2008

Question

  • 2,595 People Helped

Lawn Boy Kerosene Torpedo Heater, ph100 it sort of

Lawn Boy Kerosene Torpedo Heater, ph100 it sort of spits and sputters, on and off there is flame coming out at output end of heater for a second or so. There appears to be some sort of light at the electrical end of the machine that goes out at the same time there is flame, it's on when there is no flame. the heater continues to run when this happens. I've increased and decrease run pressure but doesn't help.

Posted by on

Answer

  • Most Helpful of 1 Answers

Hi,
Here are a couple of tips that I wrote that tell you how to troubleshoot aTorpedo or Reddy heater...

Reddy Heater - Troubleshooting Torpedo Heaters Torpedo Heater Pump Pressure Adjustment
heatman101

Posted on Oct 31, 2010

Question

  • 2,437 People Helped

Reddy Heater won't stay running

Model R150A fires but won't stay running, shuts down after about 1 minute. Air pressure is set at 5lbs, new spark plug, end cover and all filters. What should be checked next?

Posted by on

Answer

  • Most Helpful of 1 Answers

Dear travelinman4, 02-21-2009 18:24 EST (USA)

Re: Reddy Heater "Won't Stay Running"
Model R150A

Old Fuel? Added a Can of Fuel Booster? Used Starter Fluid?
Spark Plug or Igniter?
Gas, Propane, or Kerosene?

jack
c132367.jpg

Posted on Feb 21, 2009

Question

  • 1,894 People Helped

kerosene heater won't stay lit

I have an old Sears model 583409130 85,000 btu heater that starts just fine runs for a few seconds and trips the reset switch.

Posted by on

Answer

  • Most Helpful of 1 Answers

check to see if the photo cell is clean.to check it open the side compartment and look for the blue and white wire comming from photo cell,on the reset switch there is a white wire and a blue wire.hook these two wires to gether at the switch and try to refire the unit.if the unit keeps running the photo cell is bad and NEEDS to be changed.if the unit shuts off the safety switch is bad.

Posted on Feb 25, 2009

Question

  • 1,877 People Helped

heater runs a few minutes

heater runs a few minutes then blows smoke and cuts off

Posted by on

Answer

  • Most Helpful of 1 Answers

Are you using the old fuel from last year? If so, drain and clean the tank. Replace with fresh fuel and replace the fuel filter. Check or replace the air filters. Check your ignitor for proper operation. Test again. Good luck.

Posted on Dec 01, 2010

Question

  • 1,835 People Helped

Reddy Heater 55 Wont Fire

Reddy Heater 55 wont Fire

Posted by on

Answer

  • Most Helpful of 1 Answers

Hi,
Here are a couple of tips that I wrote that tell you how to troubleshoot aTorpedo or Reddy heater...

Reddy Heater - Troubleshooting Torpedo Heaters Torpedo Heater Pump Pressure Adjustment
heatman101
///

Posted on Oct 31, 2010

Question

  • 1,644 People Helped

keep getting E1 error code,

keep getting E1 error code, where is the fuel pump located? where is the fuel filter located on my dyna glo deluxe multi feul 170000 btu heater

Posted by on

Answer

  • Most Helpful of 1 Answers

The fuel pump is directly behind the fan motor as the fan motor runs both. The fuel filter is under the electrical control panel on the side of the heater usually has four to six 5/16 head sheet metal screws that hold it on. Remove the screws and then the cover comes off and this is where you will find the fuel filter.

Posted on Dec 21, 2010

Question

  • 1,617 People Helped

pro 110, runs 10 min., blows white smoke ,shuts off

I have a Reddy Heater Pro 110, several years old, has been a good heater, usually run kerosene, recently running diesel #2, have run several tanks through, no problems, recently acting up, will run for 10-15 min., then blows puffs of white smoke sparatically until shutting itself down or me unplugging it, i have no manual, have turned screws, lost track of correct position, where are screws suppose to be set, do i have other problems, ive cleaned spark plug, replaced fuel filter, cleaned air filter, ANY HELP? THANK YOU.

Posted by on

Answer

  • Most Helpful of 1 Answers

the first thing you need to do is go back to useing K1 kerosene, diesel fuel not only burns dirty but also has a tendency to gel up in cold weather which could be makeing it hard for the heater to draw the proper amount of fuel. To reset the pressure you will need a gage, it should run at about 6-7 psi. you can order a pressure gage from mr. heater online, they are by far the cheapest I have found as they are the actual manufacturer or call 1-800-251-0001

Posted on Feb 05, 2009

Question

  • 1,568 People Helped

I need a owners manual for my reddy heater 170t,

I need a owners manual for my reddy heater 170t, how can I find one?

Posted by on

Answer

  • Most Helpful of 2 Answers

I think the actual model number for this is RL170AT

This is a DESA manual but the same exact model except for the name:
http://assets.phpdistribution.com/manuals/Manuals_Page/113170-01E.pdf

Over the years DESA INTERNATIONAL has manufactured kerosene heaters with the following brand names and Reddy Parts stocks parts for them all:

  • dayton%203e218cred.gifReddy
  • Master
  • Koehring
  • Knipco
  • Amoco
  • John Deere
  • Dayton
  • Queen Bee
  • Co-op
  • and many private label brands
If you ever need parts here is the source:
http://www.reddyparts.com/

Thanks for choosing FixYa,
Kelly

Posted on Nov 19, 2010

Question

  • 1,402 People Helped

reddy heater pro 110

starts up and fires up, runs for 2-3 min. then blows a puff of smoke ans shuts down. will not restart until you unplug it and plug it back in

Posted by on

Answer

  • Most Helpful of 1 Answers

My best guess is that you are are connecting to your AC receptacle with an extention cord that is too small. The Reddy Heater contains a computer that will shut the unit off if it cannot pull enough amps from your service. The longer the cord the higher the loss from receptacle to unit. This loss can be reduced by increasing the size of your extention cord. I run a 100' 10/2 cord.

Hope this helps!

Handy Home Guy
Boone, NC
HandyHomeGuy.com

Posted on Nov 22, 2008

389 questions posted

Ask a Question

Usually answered in minutes!

Top Reddy Heating & Cooling Experts

Paul Carew

Level 3 Expert

3527 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Fahr Quad

Level 3 Expert

774 Answers

Are you a Reddy Heating and Cooling Expert? Answer questions, earn points and help others