I would provide one but you did not post the model number.
Appliance 911 Sea Breeze

Hotpoint... | 36 views | 0 helpful votes


Probably your Refrigerator is a victim of power surge an has some vital circuirs burnes out. Cal an exetr repair technician and for nex tiem bu a Refrigataror Surge Protector
Electronic Surge Protector for Refrigerators up to 27 Cuft and Freezers

Hotpoint... | 161 views | 0 helpful votes


Meaning it is on when door is closed, how do you know? Generally there is only one reason, the pressure switch is defective, and they pop out easily, so pressing it manually will disclose if switch is faulty if lite does not turn off and on while depressing, sometimes you can fix switches by cleaning contacts.
FREE-PPV.com

Hotpoint... | 102 views | 0 helpful votes


FREEZER /FRIDGE NOT COOLING: Optimum refrigerator temperature at or below40° F(4° C). The freezer temperature should be0° F(-18° C). Check temperatures periodically. Appliance thermometers are the best way of knowing these

Check ur cold control thermostat, ur thermistors in both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as per ur model ), ur air flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) On thermistors check for A close circuit and amount of ohms not just an Ohm reading. As per ur model. Most should atleast show 1200 ohms. Also Check door seals for leakage.
Evaporator coils
Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets.
If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited.

FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly.

Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air.

But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer.


Condenser
Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator.
May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

THE COMPRESSOR:
If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed.

To check ur compressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, some located next to compressor in a casing.

You wills see 3 prongs coming out of compressor. 1 goes to ur srtart winding, 1 goes to ur run winding and the center goes to ur ground.

Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms

Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity

Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required.


Read more:http://removeandreplace.com/2013/10/31/fix-refrigerator-freezer-wont-cool-freeze/#ixzz3WDEo5NDJ

REMEMBER GOD IS THE REASON FOR GOOD ADVICE"


Refrigerator Is Not Cooling What To Check And How To Fix

Hotpoint... | 46 views | 0 helpful votes


Some water filters are installed on the water supply line from the back of the fridge, others have inside the door. Find the schematic for your Hotpoint on-line at a parts suppliers and it will show you exactly where, if it's not obvious.

Hotpoint... | 51 views | 1 helpful votes


Freezer /fridge water/ice in fridge and or freezer

Usually due to CONDENSATION due to bad door seals or a plugged evaporator drain line? Can use a soft flexable tubing and very hot water to clean it out. Bad door seals usually need replacement, but u can use a blow dryer and something to pry it closer to the door wall while blowing hot air on to it. To create a seal, to test for bad door seals place a dollar bill in between the door and wall of fridge where it closes. Then slide out the dollar bill with door closed. It should offer some resistance and not be easy to pull out.
Most all fridges have a drain. Look inside your fridge for a "V" shaped channel with a small hole. This hole leads to a tube and a small pan which sits on top of your refrigerator's compressor. The defrost cycle causes water to run into the channel, down the tube, and then it generally evaporates with the heat of the hot condenser/compressor.
However, if that tube is clogged with food crumbs, particles , debris etc, you will have to clear it to get back to a normal mode of operation. A toothpick, pipecleaner, straw or a cotton bud can often do the trick.
Even a frost free freezer will still ice up at times in the areas away from the heated defrost area and the drain line can freeze. This icing causes the pipe work to the compressor to ice over or sweat and cause a puddle. Or if the drainage has frozen over, it will need to be de-iced. ( usually the line is under the freezer bottom plate covering. Towards the back of the unit) And there is another inside the fridge area also.
Give the freezer a good overnight defrost until it's totally clear of ice in addition to making sure the drain is clear to the pan at the back and then restart the freezer.

Hotpoint... | 210 views | 0 helpful votes


Freezer /fridge water/ice in fridge and or freezer

Usually due to CONDENSATION due to bad door seals or a plugged evaporator drain line? Can use a soft flexable tubing and very hot water to clean it out. Bad door seals usually need replacement, but u can use a blow dryer and something to pry it closer to the door wall while blowing hot air on to it. To create a seal, to test for bad door seals place a dollar bill in between the door and wall of fridge where it closes. Then slide out the dollar bill with door closed. It should offer some resistance and not be easy to pull out.
Most all fridges have a drain. Look inside your fridge for a "V" shaped channel with a small hole. This hole leads to a tube and a small pan which sits on top of your refrigerator's compressor. The defrost cycle causes water to run into the channel, down the tube, and then it generally evaporates with the heat of the hot condenser/compressor.
However, if that tube is clogged with food crumbs, particles , debris etc, you will have to clear it to get back to a normal mode of operation. A toothpick, pipecleaner, straw or a cotton bud can often do the trick. Another trick one can use is to connect a copper tube wire with one end going into the drain hole then attach the other end to the heater wrap it around heater a few times. That will take care of the drain problem when it comes to ice build up but not food build up.
Even a frost free freezer will still ice up at times in the areas away from the heated defrost area and the drain line can freeze. This icing causes the pipe work to the compressor to ice over or sweat and cause a puddle. Or if the drainage has frozen over, it will need to be de-iced. ( usually the line is under the freezer bottom plate covering. Towards the back of the unit) And there is another inside the fridge area also.
Give the freezer a good overnight defrost until it's totally clear of ice in addition to making sure the drain is clear to the pan at the back and then restart the freezer.
God is so good: so this is why I give free advice so please thank him not me.











hotpoint-ice-diamond-model-rfa51p-alot-iizpua1124tc1voeqjalmrl5-3-0.jpg

hotpoint-ice-diamond-model-rfa51p-alot-iizpua1124tc1voeqjalmrl5-3-2.jpg

hotpoint-ice-diamond-model-rfa51p-alot-iizpua1124tc1voeqjalmrl5-3-5.jpg

hotpoint-ice-diamond-model-rfa51p-alot-iizpua1124tc1voeqjalmrl5-3-9.jpg

hotpoint-ice-diamond-model-rfa51p-alot-iizpua1124tc1voeqjalmrl5-3-20.jpg

Hotpoint... | 183 views | 0 helpful votes


Most refrigerators have a normal start up control setting of half way. So if the control has numbers 1 to 9 the normal setting would be 5. If lettered like A to E middle would be C. Excessive frost and ice build up is usually a sign of an air leak. Check the door gasket for gaps or cuts and replace if needed. Another possible problem is if you have an interior light it might be staying on. The cause would be a bad door switch.

Hotpoint... | 67 views | 1 helpful votes


how u declare that freezer is ok?

Hotpoint... | 56 views | 0 helpful votes


FREEZER /FRIDGE NOT COOLING: Optimum refrigerator temperature at or below40° F(4° C). The freezer temperature should be0° F(-18° C). Check temperatures periodically. Appliance thermometers are the best way of knowing these

Check ur cold control thermostat, ur thermistors in both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as per ur model ), ur air flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) On thermistors check for A close circuit and amount of ohms not just an Ohm reading. As per ur model. Most should atleast show 1200 ohms. Also Check door seals for leakage.
Evaporator coils
Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets.
If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited.

FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly.

Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air.

But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer.


Condenser
Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator.
May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

THE COMPRESSOR:
If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed.

To check ur compressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, some located next to compressor in a casing.

You wills see 3 prongs coming out of compressor. 1 goes to ur srtart winding, 1 goes to ur run winding and the center goes to ur ground.

Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms

Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity

Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required.





Read more:
REMEMBER GOD IS THE REASON FOR GOOD ADVICE"










hotpoint-ff80-running-not-cooling-kvax0h5nolktkyinzrohy2he-2-0.jpg

hotpoint-ff80-running-not-cooling-kvax0h5nolktkyinzrohy2he-2-2.png

hotpoint-ff80-running-not-cooling-kvax0h5nolktkyinzrohy2he-2-5.jpg

hotpoint-ff80-running-not-cooling-kvax0h5nolktkyinzrohy2he-2-9.jpg

hotpoint-ff80-running-not-cooling-kvax0h5nolktkyinzrohy2he-2-14.jpg

hotpoint-ff80-running-not-cooling-kvax0h5nolktkyinzrohy2he-2-20.jpg

Hotpoint... | 330 views | 0 helpful votes


Dave,
You should not need new hinges. As long as you have screw holes on both sides you re-use the same hinges, just flip the middle one over. The bottom hinge point, you will need to move the post from one side to the other. Hope this helps!

Hotpoint... | 72 views | 1 helpful votes


Hello;

My name is peter. I am a retired field service refrigeration technician.

All too often people purchase new appliances when the component that failed is about $30.00.

A refrigerator especially a Hotpoint should last you 25-30 years if maintained.

I once had a service call where I had thought the service order was not right. I arrived at the customers home. The unit was 33 years old. I was pleased when I had the repair part on my truck and helped this elder women.

Your unit date is on a label in the fresh food section on the upper inside wall.

I do work part time locally. Give me a call. 443-306-1362.
Glen Burnie, MD.

Hotpoint... | 222 views | 0 helpful votes


Normally when there is a frost build up, the defrost timer is not working properly. The fridge will not run when in defrost. Some of the newer refrigerators have printed circuit boards that control the operation. Most older units have a separate timer that controls the defrost cycle.

Hotpoint... | 55 views | 0 helpful votes


May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

Hotpoint... | 139 views | 0 helpful votes

Not finding what you are looking for?
Hotpoint RFA60 Bottom Freezer Refrigerator Logo

32 questions posted

Ask a Question

Usually answered in minutes!

Top Hotpoint Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4656 Answers

jasbo
jasbo

Level 3 Expert

2239 Answers

jdthefixer

Level 3 Expert

746 Answers

Are you a Hotpoint Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Hotpoint Refrigerators

  • Hotpoint Refrigerators

Most Popular Question

rfa60 fridge freezer red light freezer

  • Refrigerators
Loading...