Sharp AR-M160 Laser Printer - Answered Questions & Fixed issues
Sharp AR-M160 Maintenance light and developer
It's not developer light.
It is drum unit light and maintenance.
You have to replace the Drum, Blade and Developer.
After changing them you have to reset the maintenance, drum,developer counter.
This procedure must be made by a copier tech.
But if you still want only the developer the code is AR-202D
11/28/2019 11:10:32 AM •
Sharp AR-M160...
•
Answered
on Nov 28, 2019
•
1,703 views
My Sharp Copier Model AR-M160
Below are the F2 errors and causes for Sharp AR-M160
"F2-31" Image density sensor fault
"F2-32" Drum mark sensor fault
"F2-33" Grid voltage correction problem
"F2-35" Grid voltage correction problem
"F2-37" Drum mark sensor fault
Cause : CRUM chip defect OR Improper developing unit
Check and remedy : As you have already replaced the tonner, we can suggest Replace the CRUM chip,Replace the developing unit
Regards,
Shrey
5/19/2016 10:09:33 AM •
Sharp AR-M160...
•
Answered
on May 19, 2016
•
1,142 views
HOW CAN i CLEAR h4?
1. Entering the simulation mode
Perform the following procedure to enter the simulation mode.
"#" key "*" key "C" key "*" key
Main code 14 Start key Sub code 0 Start key
OR
"#" key "INTERRUPT" key "C" key "INTERRUPT"
Main code 14 Start key Sub code 0 Start key
2. Canceling the simulation mode
When the clear all key is pressed, the simulation mode is cancelled.
When the interruption key is pressed, the process is interrupted and the
screen returns to the sub code entering display.
* After canceling the simulation mode, be sure to turn OFF/ON the
power and check the operation.
Note: If the machine is terminated by a jam error or paper empty during copying in the adjustment by the simulation, recopying is required.
DO NOT CONTINUE RESET AS THIS CAN CAUSE A FIRE AND RUIN A PERFECTLY GOOD DAY. Btw, I’m available to help over the phone in case u need at
https://www.6ya.com/expert/normanj_7893313f0751935f
Sharp AR-M160 H4 error code
Clearing a trouble code on a AR-M160 is a little different than the AR160.
Try "#" "interrupt" "clear" "interupt" "1" "4" "start key"
This should clear the error. Even if you replace the fusion unit you will need this code to clear the error
3/7/2024 11:15:00 AM •
Sharp AR-M160...
•
Answered
on Mar 07, 2024
•
3,505 views
ERROR CODE L6
Polygon motor lock detection
Detail : The polygon motor does not rotate.
The motor lock signal is detected for 6sec after
rotation of the polygon motor. The motor lock
signal is detected for 1sec during rotation of the
polygon motor.
Cause : Polygon motor unit abnormality
Improper connection or disconnection of the
polygon motor and the harness.
MCU PWB abnormality
Check and remedy : Use SIM 61-1 to check the polygon motor
operations.
Check connection of the polygon motor
harness/connector.
Replace the polygon motor..
Replace the MCU PWB.
H4 error
H4 00 Heat roller low temperature detection
Press: "Clear", "Interupt", "0", "Interupt", "14", "Start Key"
10/26/2013 10:17:31 AM •
Sharp AR-M160...
•
Answered
on Oct 26, 2013
•
104 views