Change dry capacitor C13 47uF/50V. Change capacitor C17 220uF/35V if bulged. While you are soldering, change capacitor C16 10uF/50V at the same time.

Powercom... | Answered on Apr 23, 2019


sounds like it needs a new battery.

Powercom... | Answered on Feb 14, 2012


If you unplug the unit and it powers your PC for 3 or 4 hours then turns off, it is because the batteries are empty and this is normal. If it is plugged-in with power and shuts itself off after a few hours, then the battery cells may be in need of replacing. You can purcase an inexpensive replacement battery here: http://www.upsforless.com/browseproducts/Powercom-Replacement-Battery-Kit-BNT-500A-BNT-500AP-BNT-600AP-BNT-800AP-KIN-425CSU-KIN-625CS.HTML

Powercom... | Answered on Feb 14, 2012


hi there check the fuse and let me know the condition of that.

Powercom... | Answered on Jan 19, 2011


plzzzz help in providing the circuit diagram of the ind601a model board ;;; -8985043391

Powercom... | Answered on Dec 02, 2010


Hi

After 3 years, i would by a new UPS...

The battery will have to be changed if you want to keep the old one.

What i've seen mostly here in south africa. When the battery life has ended they customer opens the ups and takes out the battery and then connects a car battery to the terminals. The then close the ups and let the car battery stand outside the ups.

Hope this info helps...

Powercom... | Answered on Apr 26, 2009


You may need to change the battery within the battery backup. The normal lifetime of a battery is roughly 3 years.

Powercom... | Answered on Mar 18, 2009


The replacement batteries could be defective or installed incorrectly.

Powercom... | Answered on Dec 02, 2018


If you're saying that there is voltage output on the input wire when unplugged from the wall you should contact the manufactureer as this is a defect.

Powercom... | Answered on Oct 28, 2014


I do not understand your question.

Powercom... | Answered on Oct 09, 2013


Is the load exceeding the UPS capacity?
Which model UPS do you have and what type of load is connected to it?

Regards,


Ron

Powercom... | Answered on Aug 01, 2013

Not finding what you are looking for?
Powercom BNT-600AP (bnt600ap) UPS System Logo

16 questions posted

Ask a Question

Usually answered in minutes!

Top Powercom Computers & Internet Experts

Ekse

Level 3 Expert

13434 Answers

Marvin
Marvin

Level 3 Expert

85231 Answers

Brad Brown

Level 3 Expert

18195 Answers

Are you a Powercom Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Powercom Computers & Internet

  • Powercom Computers & Internet

Most Popular Question

not charge battery

  • Computers & Internet
Loading...